Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy

被引:4
|
作者
Guillou, Manon [1 ]
L'Homme, Bruno [1 ]
Trompier, Francois [2 ]
Gruel, Gaetan [1 ]
Prezado, Yolanda [3 ]
Dos Santos, Morgane [1 ]
机构
[1] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SERAMED LRAcc, Fontenay Aux Rroses, France
[2] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SDOS LDRI, Fontenay Aux Roses, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, Inserm U 1021 CNRS ,UMR 3347, Orsay, France
关键词
dosimetry; low energy X-rays; interventional radiology; radiological burn; preclinical model; EPR spectroscopy; Monte Carlo simulation; KILOVOLTAGE PHOTON; RADIATION-THERAPY; DOSE PERTURBATION; BONE; RADIOTHERAPY; ACCIDENT; PLATFORM;
D O I
10.3389/fphys.2022.1075665
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Interventional radiology has grown considerably over the last decades and become an essential tool for treatment or diagnosis. This technique is mostly beneficial and mastered but accidental overexposure can occur and lead to the appearance of deterministic effects. The lack of knowledge about the radiobiological consequences for the low-energy X-rays used for these practices makes the prognosis very uncertain for the different tissues. In order to improve the radiation protection of patients and better predict the risk of complications, we implemented a new preclinical mouse model to mimic radiological burn in interventional radiology and performed a complete characterization of the dose deposition. A new setup and collimator were designed to irradiate the hind legs of 15 mice at 30 Gy in air kerma at 80 kV. After irradiation, mice tibias were collected to evaluate bone dose by Electron Paramagnetic Resonance (EPR) spectroscopy measurements. Monte Carlo simulations with Geant4 were performed in simplified and voxelized phantoms to characterize the dose deposition in different tissues and evaluate the characteristics of secondary electrons (energy, path, momentum). 30 mice tibias were collected for EPR analysis. An average absorbed dose of 194.0 & PLUSMN; 27.0 Gy was measured in bone initially irradiated at 30 Gy in air kerma. A bone to air conversion factor of 6.5 & PLUSMN; 0.9 was determined. Inter sample and inter mice variability has been estimated to 13.9%. Monte Carlo simulations shown the heterogeneity of the dose deposition for these low X-rays energies and the dose enhancement in dense tissue. The specificities of the secondary electrons were studied and showed the influence of the tissue density on energies and paths. A good agreement between the experimental and calculated bone to air conversion factor was obtained. A new preclinical model allowing to perform radiological burn in interventional radiology-like conditions was implemented. For the development of new preclinical radiobiological model where the exact knowledge of the dose deposited in the different tissues is essential, the complementarity of Monte Carlo simulations and experimental measurements for the dosimetric characterization has proven to be a considerable asset.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Investigation of the radiological properties of various phantoms for their application in low energy X-rays dosimetry
    Langaroodi, Roghayeh Kargar Shaker
    Abtahi, Seyed Mohammad Mahdi
    Akbari, Mohammad Esmaeil
    RADIATION PHYSICS AND CHEMISTRY, 2019, 157 : 33 - 39
  • [2] ACCURATE DOSIMETRY OF LOW-ENERGY X-RAYS
    LYONS, PB
    BARAN, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 908 - &
  • [3] Dosimetry of Low-Energy Characteristic X-Rays
    Tucker, M.
    Starin, R.
    McCray, M.
    Rakowski, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] The use of Fricke dosimetry for low energy X-rays
    de Austerlitz, C
    Souza, V
    Villar, HP
    Cordilha, A
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2006, 49 : 17 - 23
  • [5] THE APPLICATION OF MICRODOSIMETRIC MEASUREMENTS TO THE STUDY OF THE DOSIMETRY OF LOW-ENERGY X-RAYS
    WAKER, AJ
    EIVAZI, MT
    RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 75 - 79
  • [6] Monte Carlo study of interactions of X-rays with image intensifier
    Guo, Jinchuan
    Niu, Hanben
    Guangxue Xuebao/Acta Optica Sinica, 1998, 18 (09): : 1197 - 1202
  • [7] Suitability of radiochromic films for dosimetry of low energy X-rays
    Ebert, Martin A.
    Asad, Ali H.
    Siddiqui, Salim A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 232 - 240
  • [8] DOSIMETRY OF LOW-ENERGY X-RAYS USING LIF
    LAW, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01): : 38 - 45
  • [9] Monte Carlo calculation of x-rays deposited energy in CdZnTe detector
    Stankovic, Sj
    Petrovic, M.
    Kovacevic, M.
    Vasic, A.
    Osmokrovic, P.
    Loncar, B.
    RESEARCH TRENDS IN CONTEMPORARY MATERIALS SCIENCE, 2007, 555 : 141 - +
  • [10] Effective energy assessment during breast cancer intraoperative radiotherapy by low-energy X-rays: A Monte Carlo study
    Shamsabadi, Reza
    Baghani, Hamid Reza
    Mowlavi, Ali Asghar
    Azadegan, Behnam
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2021, 60 (01) : 125 - 134