Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy

被引:4
|
作者
Guillou, Manon [1 ]
L'Homme, Bruno [1 ]
Trompier, Francois [2 ]
Gruel, Gaetan [1 ]
Prezado, Yolanda [3 ]
Dos Santos, Morgane [1 ]
机构
[1] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SERAMED LRAcc, Fontenay Aux Rroses, France
[2] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SDOS LDRI, Fontenay Aux Roses, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, Inserm U 1021 CNRS ,UMR 3347, Orsay, France
关键词
dosimetry; low energy X-rays; interventional radiology; radiological burn; preclinical model; EPR spectroscopy; Monte Carlo simulation; KILOVOLTAGE PHOTON; RADIATION-THERAPY; DOSE PERTURBATION; BONE; RADIOTHERAPY; ACCIDENT; PLATFORM;
D O I
10.3389/fphys.2022.1075665
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Interventional radiology has grown considerably over the last decades and become an essential tool for treatment or diagnosis. This technique is mostly beneficial and mastered but accidental overexposure can occur and lead to the appearance of deterministic effects. The lack of knowledge about the radiobiological consequences for the low-energy X-rays used for these practices makes the prognosis very uncertain for the different tissues. In order to improve the radiation protection of patients and better predict the risk of complications, we implemented a new preclinical mouse model to mimic radiological burn in interventional radiology and performed a complete characterization of the dose deposition. A new setup and collimator were designed to irradiate the hind legs of 15 mice at 30 Gy in air kerma at 80 kV. After irradiation, mice tibias were collected to evaluate bone dose by Electron Paramagnetic Resonance (EPR) spectroscopy measurements. Monte Carlo simulations with Geant4 were performed in simplified and voxelized phantoms to characterize the dose deposition in different tissues and evaluate the characteristics of secondary electrons (energy, path, momentum). 30 mice tibias were collected for EPR analysis. An average absorbed dose of 194.0 & PLUSMN; 27.0 Gy was measured in bone initially irradiated at 30 Gy in air kerma. A bone to air conversion factor of 6.5 & PLUSMN; 0.9 was determined. Inter sample and inter mice variability has been estimated to 13.9%. Monte Carlo simulations shown the heterogeneity of the dose deposition for these low X-rays energies and the dose enhancement in dense tissue. The specificities of the secondary electrons were studied and showed the influence of the tissue density on energies and paths. A good agreement between the experimental and calculated bone to air conversion factor was obtained. A new preclinical model allowing to perform radiological burn in interventional radiology-like conditions was implemented. For the development of new preclinical radiobiological model where the exact knowledge of the dose deposited in the different tissues is essential, the complementarity of Monte Carlo simulations and experimental measurements for the dosimetric characterization has proven to be a considerable asset.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Monte Carlo Modeling of DNA Lesions and Chromosomal Aberrations Induced by Mixed Beams of Alpha Particles and X-Rays
    Brzozowska, Beata
    Tartas, Adrianna
    Wojcik, Andrzej
    FRONTIERS IN PHYSICS, 2020, 8
  • [32] The energy dependence of BaSO4: Eu nanophosphors for thermoluminescence dosimetry of orthovoltage X-rays and low
    Nattudurai, Ravikumar
    Arous, Delmon
    Edin, Nina F. J.
    Pandey, Anant
    Malinen, Eirik
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [33] SIMULATION STUDY ON THE BEHAVIOR OF X-RAYS AND GAMMA-RAYS IN AN INHOMOGENEOUS-MEDIUM USING THE MONTE-CARLO TECHNIQUE
    MURASE, K
    KATAOKA, M
    KAWAMURA, M
    TANADA, S
    HAMAMOTO, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1989, 28 (06): : 1072 - 1078
  • [34] Monte Carlo dosimetry using Fluka code and experimental dosimetry with Gafchromic EBT2 and XR-RV3 of self-built experimental setup for radiobiological studies with low-energy X-rays
    Czub, Joanna
    Braziewicz, Janusz
    Wasilewski, Adam
    Wysocka-Rabin, Anna
    Wolowiec, Pawel
    Wojcik, Andrzej
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2020, 96 (06) : 718 - 733
  • [35] Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source
    Bouzid, Dounia
    Bert, Julien
    Dupre, Pierre-Francois
    Benhalouche, Saadia
    Pradier, Olivier
    Boussion, Nicolas
    Visvikis, Dimitris
    ACTA ONCOLOGICA, 2015, 54 (10) : 1788 - 1795
  • [36] An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams
    Zeng, GG
    McEwen, MR
    Rogers, DWO
    Klassen, NV
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 257 - 270
  • [37] Comparison of measured backscatter factors with Monte Carlo simulations for low energy X-ray
    Kim, Min Suk
    Ryu, Jun Seok
    Park, Shin-Woong
    Yi, Yun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 341 - 344
  • [38] Radiopathological consequences of low energy X-rays overexposures: a dose effect study
    Guillou, M.
    L'Homme, B.
    Trompier, F.
    Errabii, A.
    Gruel, G.
    Prezado, Y.
    Dos Santos, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1986 - S1987
  • [39] Study of the response function of a HPGe detector for low-energy X-rays
    Lépy, MC
    Plagnard, J
    Ferreux, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 290 - 293
  • [40] Design and performance study of a proportional counter for low-energy X-rays
    Li, Meng Yu
    Zhao, Rui
    Xiong, Tao
    Wu, Jin Jie
    Fu, Lin
    Yu, Tao
    Zhu, Wei Feng
    Tang, Xian Qiang
    Lu, Ping Zhou
    Qu, Bing Bing
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206