Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy

被引:4
|
作者
Guillou, Manon [1 ]
L'Homme, Bruno [1 ]
Trompier, Francois [2 ]
Gruel, Gaetan [1 ]
Prezado, Yolanda [3 ]
Dos Santos, Morgane [1 ]
机构
[1] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SERAMED LRAcc, Fontenay Aux Rroses, France
[2] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SDOS LDRI, Fontenay Aux Roses, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, Inserm U 1021 CNRS ,UMR 3347, Orsay, France
关键词
dosimetry; low energy X-rays; interventional radiology; radiological burn; preclinical model; EPR spectroscopy; Monte Carlo simulation; KILOVOLTAGE PHOTON; RADIATION-THERAPY; DOSE PERTURBATION; BONE; RADIOTHERAPY; ACCIDENT; PLATFORM;
D O I
10.3389/fphys.2022.1075665
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Interventional radiology has grown considerably over the last decades and become an essential tool for treatment or diagnosis. This technique is mostly beneficial and mastered but accidental overexposure can occur and lead to the appearance of deterministic effects. The lack of knowledge about the radiobiological consequences for the low-energy X-rays used for these practices makes the prognosis very uncertain for the different tissues. In order to improve the radiation protection of patients and better predict the risk of complications, we implemented a new preclinical mouse model to mimic radiological burn in interventional radiology and performed a complete characterization of the dose deposition. A new setup and collimator were designed to irradiate the hind legs of 15 mice at 30 Gy in air kerma at 80 kV. After irradiation, mice tibias were collected to evaluate bone dose by Electron Paramagnetic Resonance (EPR) spectroscopy measurements. Monte Carlo simulations with Geant4 were performed in simplified and voxelized phantoms to characterize the dose deposition in different tissues and evaluate the characteristics of secondary electrons (energy, path, momentum). 30 mice tibias were collected for EPR analysis. An average absorbed dose of 194.0 & PLUSMN; 27.0 Gy was measured in bone initially irradiated at 30 Gy in air kerma. A bone to air conversion factor of 6.5 & PLUSMN; 0.9 was determined. Inter sample and inter mice variability has been estimated to 13.9%. Monte Carlo simulations shown the heterogeneity of the dose deposition for these low X-rays energies and the dose enhancement in dense tissue. The specificities of the secondary electrons were studied and showed the influence of the tissue density on energies and paths. A good agreement between the experimental and calculated bone to air conversion factor was obtained. A new preclinical model allowing to perform radiological burn in interventional radiology-like conditions was implemented. For the development of new preclinical radiobiological model where the exact knowledge of the dose deposited in the different tissues is essential, the complementarity of Monte Carlo simulations and experimental measurements for the dosimetric characterization has proven to be a considerable asset.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Pinhole X-ray fluorescence imaging of gadolinium and gold nanoparticles using polychromatic X-rays: a Monte Carlo study
    Jung, Seongmoon
    Sung, Wonmo
    Ye, Sung-Joon
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 5805 - 5817
  • [42] Monte Carlo-based evaluation of the relevant RBE values to produced low-energy X-rays by INTRABEAM and Axxent dedicated IORT facilities
    Shamsabadi, Reza
    Baghani, Hamid Reza
    Azadegan, Behnam
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (04):
  • [43] DIFFERENCES IN REPORTED BACKSCATTER FACTORS FOR LOW-ENERGY X-RAYS - A LITERATURE STUDY
    CARLSSON, CA
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (04): : 521 - 531
  • [44] THE FANO FACTOR IN GASEOUS XENON - A MONTE-CARLO CALCULATION FOR X-RAYS IN THE 0.1 TO 25 KEV ENERGY-RANGE
    DIAS, THVT
    SANTOS, FP
    STAUFFER, AD
    CONDE, CAN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3): : 341 - 346
  • [45] Study of induced thermoluminescence in CVD diamond film by low-energy X-rays
    Liu, CC
    Lin, JP
    Chu, TC
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (01) : 79 - 85
  • [46] A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source
    Williams, Kerry
    Robinson, Neil
    Trapp, Jamie
    Ackerly, Trevor
    Das, Ram
    Kemp, Penny
    Geso, Moshi
    JOURNAL OF MEDICAL PHYSICS, 2007, 32 (02) : 73 - 76
  • [47] A comprehensive Monte Carlo study to design a novel multi-nanoparticle loaded nanocomposites for augmentation of attenuation coefficient in the energy range of diagnostic X-rays
    Sayyadi, Elahe
    Mesbahi, Asghar
    Zamiri, Reza Eghdam
    Nejad, Farshad Seyyed
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (04): : 279 - 289
  • [48] MONTE-CARLO SIMULATIONS OF SECONDARY-ELECTRON EMISSION FROM CSI, INDUCED BY 1-10 KEV X-RAYS AND ELECTRONS
    AKKERMAN, A
    GIBREKHTERMAN, A
    BRESKIN, A
    CHECHIK, R
    JOURNAL OF APPLIED PHYSICS, 1992, 72 (11) : 5429 - 5436
  • [49] Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response
    Hranitzky, C.
    Stadtmann, H.
    Olko, P.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 483 - 486
  • [50] SHORT-TERM VARIABILITY OF X-RAYS FROM ACCRETING NEUTRON STAR VELA X-1. II. MONTE CARLO MODELING
    Odaka, Hirokazu
    Khangulyan, Dmitry
    Tanaka, Yasuyuki T.
    Watanabe, Shin
    Takahashi, Tadayuki
    Makishima, Kazuo
    ASTROPHYSICAL JOURNAL, 2014, 780 (01):