Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source

被引:22
|
作者
Bouzid, Dounia [1 ,2 ]
Bert, Julien [1 ]
Dupre, Pierre-Francois [3 ]
Benhalouche, Saadia [1 ]
Pradier, Olivier [1 ,2 ]
Boussion, Nicolas [1 ,2 ]
Visvikis, Dimitris [1 ]
机构
[1] INSERM, UMR1101, LaTIM, Brest, France
[2] CHRU Brest, Dept Radiotherapy, Brest, France
[3] CHRU Brest, Dept Gynecol & Surg, Brest, France
关键词
DOSE CALCULATION; BRACHYTHERAPY; TARGIT; GPU; RADIOSURGERY; SIMULATIONS; PARAMETERS; MINIATURE; MODEL; CT;
D O I
10.3109/0284186X.2015.1016623
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intraoperative radiotherapy (IORT) is continuously gaining ground in cancer treatment. However, there is currently no planning system associated with these devices, which precludes patient-specific dose delivery optimization. The objective of this study was the development and validation of a Monte Carlo simulation (MCS)-based dosimetry platform using the Intrabeam system.Methods. After surgical resection of the tumor this system delivers a single dose fraction at the surface of an applicator irradiating the tumor bed through a 50 kV x-ray beam. The GATE MCS platform was used in this study combining the phase space obtained by modeling the x-ray source and the detailed modeling of the additional parts of the Intrabeam system. The model was validated by comparing simulated versus experimental measurements of depth dose curves (DDC) and isotropy. A clinical validation study was also carried out using patient computed tomography images.Results. The mean deviation between measured and simulated DDC was 2.9% 4.4% and 5.9% +/- 5.7% for the bare needle and the use of applicators, respectively. A good agreement with experimental measurements was also found in terms of dose isotropy with a maximum difference of 2.04% for the 40 mm diameter applicator. A patient study revealed a mean absolute deviation of 0.06 Gy between simulated and thermoluminescent dosimeters (TLD) measured skin doses.Conclusion. This study shows the potential of using the GATE MCS platform to model three-dimensional dose distributions of the Intrabeam system for use in IORT.
引用
收藏
页码:1788 / 1795
页数:8
相关论文
共 50 条
  • [1] Diagnostic x-ray dosimetry using Monte Carlo simulation
    Ioppolo, JL
    Price, RI
    Tuchyna, T
    Buckley, CE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1707 - 1720
  • [2] MONTE-CARLO CALCULATIONS OF X-RAY BACKSCATTERING
    BERGER, MJ
    RASO, D
    [J]. RADIATION RESEARCH, 1958, 9 (01) : 91 - 91
  • [3] Energy discrimination with an X-ray pixel detector - a Monte-Carlo simulation
    Pedersen, F
    Ronnqvist, C
    Fransson, K
    Gustafsson, L
    Kullander, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 443 - 447
  • [4] Dosimetry of Low Energy Electronic Brachytherapy X-Ray Source
    Kriminski, S.
    Dorgu, A.
    Gong, J.
    Pavord, D.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3364 - +
  • [5] MONTE-CARLO STUDY OF A HARD X-RAY CONCENTRATOR
    PASQUALINI, G
    DECHIARA, P
    FRONTERA, F
    [J]. NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1990, 13 (02): : 445 - 451
  • [6] USE OF MONTE-CARLO METHOD IN X-RAY MICROANALYSIS
    DESALVO, A
    ROSA, R
    [J]. JOURNAL OF SUBMICROSCOPIC CYTOLOGY AND PATHOLOGY, 1978, 10 (01) : 153 - 153
  • [7] Monte-Carlo simulations of X-ray binary spectra
    Leahy, DA
    [J]. 12TH KINGSTON MEETING : COMPUTATIONAL ASTROPHYSICS, 1997, 123 : 109 - 111
  • [8] Modelling the biological effect of a low-energy x-ray source used for intraoperative radiotherapy (IORT)
    Herskind, C
    Steil, V
    Neumann, D
    Kraus-Tiefenbacher, U
    Wenz, F
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S359 - S360
  • [9] MONTE-CARLO SIMULATION OF CONVENTIONAL AND SYNCHROTRON ENERGY-DISPERSIVE X-RAY SPECTROMETERS
    JANSSENS, K
    VINCZE, L
    VANESPEN, P
    ADAMS, F
    [J]. X-RAY SPECTROMETRY, 1993, 22 (04) : 234 - 243
  • [10] Monte Carlo simulations for X-ray breast dosimetry using homogeneous and heterogeneous phantoms
    Tucciariello, R. M.
    Barca, P.
    Del Sarto, D.
    Lamastra, R.
    Traino, A. C.
    Fantacci, M. E.
    [J]. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2021, 44 (4-5):