摘要
It has been previously proven that the radiological properties of materials are strongly dependent on the incident radiation energy. Hence, the present study aimed to evaluate the radiological properties and soft tissue equivalency of conventional phantoms at the 1-50 keV photon energy as well as the feasibility study of using a more appropriate material instead of water. The equivalence of water and a number of conventional phantoms with breast and muscle were evaluated in terms of mass density (rho), effective electron density (N-eff), effective atomic number (Z(eff)), photon mass energy-absorption coefficient (mu(en)/rho), photon mass attenuation coefficient (mu/rho), total stopping power of electrons (S/rho)(tot) and the absorbed depth dose by using the Auto-Z(eff) software and XCOM, ESTAR database and Monte Carlo simulation method. The differences of rho, N-eff, Z(eff) and (S/rho)(tot) between investigated materials and breast were 0.5-17%, 0.2-9%, 0.7-26%, and 2-11%, respectively. Additionally, the differences of mu(en)/rho, mu/rho, and the absorbed depth dose between the investigated phantom materials and breast tissue were 18-56%, 16-53%, and 5-79% respectively. Also, the differences of rho, N-eff, Z(eff), mu(en)/rho, mu/rho, (S/rho)(tot), and the absorbed depth dose between the investigated phantom materials and muscle were 1-14%, 2-9%, 1-33%, 4-67%, 6-63%, 1-15% and 3-93%, respectively. Water cannot be considered as breast tissue equivalent phantom in the energy range of 1-50 keV. Moreover, the results of depth dose investigation showed that the GENIPIN gel is the most suitable breast tissue substitute in intraoperative radiotherapy method.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [31] On the production of X-rays by low energy ion beams
    Joy, David C.
    Meyer, Harry M., III
    Bolorizadeh, Mehdi
    Lin, Yinghong
    Newbury, Dale
    SCANNING, 2007, 29 (01) : 1 - 4
  • [32] The investigation of the properties of thin films by means of X-rays
    Bragg, W
    NATURE, 1925, 115 : 266 - 269
  • [33] Realistic dosimetry for studies on biological responses to X-rays and γ-rays
    Beni, Mehrdad Shahmohammadi
    Krstic, Dragana
    Nikezic, Dragoslav
    Yu, Kwan Ngok
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (05) : 729 - 736
  • [34] Investigation of gas generation in regenerative fuel cells by low-energy X-rays
    Selamet, Omer Faruk
    Deevanhxay, Phengxay
    Tsushima, Shohji
    Hirai, Shuichiro
    JOURNAL OF POWER SOURCES, 2015, 296 : 133 - 141
  • [35] ATTENUATION OF LOW-ENERGY X-RAYS IN THE AIR
    DIETZSCH, W
    ISOTOPENPRAXIS, 1987, 23 (12): : 456 - 459
  • [36] ELECTRET DOSIMETER FOR LOW-ENERGY X-RAYS
    RICARD, M
    LISBONA, A
    MORUCCI, JP
    ROULLEAU, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 129 - 130
  • [37] Benchmark of PENELOPE for low and medium energy X-rays
    Chica, U.
    Anguiano, M.
    Lallena, A. M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (02): : 51 - 57
  • [38] DETECTION OF LOW-ENERGY COSMIC X-RAYS
    FRANCEY, RJ
    BAIRD, GA
    GREEN, DW
    WILSON, BG
    WOOLLAM, WH
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (03): : 589 - 595
  • [40] Absorption of X-rays in various elements
    Richtmyer, FK
    NATURE, 1927, 120 : 915 - 916