Investigation of the radiological properties of various phantoms for their application in low energy X-rays dosimetry

被引:14
|
作者
Langaroodi, Roghayeh Kargar Shaker [1 ]
Abtahi, Seyed Mohammad Mahdi [1 ]
Akbari, Mohammad Esmaeil [2 ]
机构
[1] Imam Khomeini Int Univ, Phys Dept, Qazvin 3414916818, Iran
[2] Shahid Beheshti Univ Med Sci, Canc Res Ctr, Tehran, Iran
关键词
Phantom; Radiological properties; Dosimetry; Low energy X-rays; Radiation therapy; EFFECTIVE ATOMIC NUMBERS; POLYMER GEL DOSIMETER; INTRAOPERATIVE RADIOTHERAPY; WATER EQUIVALENCE; MINIATURE; RADIOSURGERY; SIMULATION; DEVICE;
D O I
10.1016/j.radphyschem.2018.12.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It has been previously proven that the radiological properties of materials are strongly dependent on the incident radiation energy. Hence, the present study aimed to evaluate the radiological properties and soft tissue equivalency of conventional phantoms at the 1-50 keV photon energy as well as the feasibility study of using a more appropriate material instead of water. The equivalence of water and a number of conventional phantoms with breast and muscle were evaluated in terms of mass density (rho), effective electron density (N-eff), effective atomic number (Z(eff)), photon mass energy-absorption coefficient (mu(en)/rho), photon mass attenuation coefficient (mu/rho), total stopping power of electrons (S/rho)(tot) and the absorbed depth dose by using the Auto-Z(eff) software and XCOM, ESTAR database and Monte Carlo simulation method. The differences of rho, N-eff, Z(eff) and (S/rho)(tot) between investigated materials and breast were 0.5-17%, 0.2-9%, 0.7-26%, and 2-11%, respectively. Additionally, the differences of mu(en)/rho, mu/rho, and the absorbed depth dose between the investigated phantom materials and breast tissue were 18-56%, 16-53%, and 5-79% respectively. Also, the differences of rho, N-eff, Z(eff), mu(en)/rho, mu/rho, (S/rho)(tot), and the absorbed depth dose between the investigated phantom materials and muscle were 1-14%, 2-9%, 1-33%, 4-67%, 6-63%, 1-15% and 3-93%, respectively. Water cannot be considered as breast tissue equivalent phantom in the energy range of 1-50 keV. Moreover, the results of depth dose investigation showed that the GENIPIN gel is the most suitable breast tissue substitute in intraoperative radiotherapy method.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [21] RESEARCH ON DOSIMETRY STANDARDS FOR HIGH ENERGY X-RAYS AND ELECTRONS.
    Tomimasu, T.
    Noguchi, T.
    Kimura, M.
    Sugiyama, S.
    Mikado, T.
    Yamazaki, T.
    Chiwaki, M.
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1983, 47 (9-10): : 876 - 889
  • [22] THE APPLICATION OF MICRODOSIMETRY TO THE METROLOGY OF LOW-ENERGY X-RAYS USED IN MAMMOGRAPHY
    WAKER, AJ
    MARCO, M
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (771): : 258 - 261
  • [23] Application of extrapolation chambers in low-energy X-rays as reference systems
    da Silva, Eric A. B.
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1411 - 1416
  • [24] The energy of x-rays
    Wien, W
    PHYSIKALISCHE ZEITSCHRIFT, 1904, 5 : 128 - 130
  • [25] The energy of x-rays
    Terrill, HM
    PHYSICAL REVIEW, 1926, 28 (03): : 0438 - 0443
  • [26] The energy dependence of BaSO4: Eu nanophosphors for thermoluminescence dosimetry of orthovoltage X-rays and low
    Nattudurai, Ravikumar
    Arous, Delmon
    Edin, Nina F. J.
    Pandey, Anant
    Malinen, Eirik
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [27] Barriers to energy dispersive spectrometry with low energy X-rays
    Rickerby, DG
    MIKROCHIMICA ACTA, 1996, : 493 - 500
  • [28] An EGSnrc investigation of air kerma calibration coefficients for low-energy x-rays
    La Russa, D.
    McEwen, M.
    Rogers, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S54 - S55
  • [29] DOSIMETRY FOR THE IRRADIATION OF POLYMERS BY SOFT X-RAYS
    SOTOBAYASHI, H
    WOLF, FP
    SCHNABEL, W
    ABOUSAMRA, N
    ASMUSSEN, F
    POLYMER JOURNAL, 1987, 19 (05) : 659 - 666
  • [30] In vitro Dosimetry at 60 kV X-rays
    Niermann, P.
    Loeckemann, F.
    Haverkamp, U.
    Schulze, H-J
    Eich, H. T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 153 - 153