The safety and feasibility of minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur: A cadaveric injection study

被引:46
|
作者
Jiamton, C. [1 ]
Apivatthakakul, T. [2 ,3 ]
机构
[1] Lerdsin Gen Hosp, Inst Orthopaed, Bangkok, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Orthoped, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Excellence Ctr, ORTC, Chiang Mai 50200, Thailand
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 11期
关键词
Femoral fracture; Minimally invasive plate osteosynthesis (MIPO); Medial approach; Femoral artery; DISTAL FEMUR; INTERNAL-FIXATION; FEMORAL FRACTURES; OSTEOTOMY; IMPLANT;
D O I
10.1016/j.injury.2015.08.032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur appears to be a dangerous procedure due to possible femoral artery injury. Objective: This study aims to determine the feasibility of applying MIPO of the femur via the medial approach, and to determine the anatomical relationship and structures at risk between the artery and the implant using computed tomography angiography. Materials and methods: A descriptive study of ten fresh cadavers was done. Two separate incisions were made, creating a submuscular tunnel close to the medial side of the femur. An 11- or 13-hole LCP lateral proximal tibial plate (5.0 mm) was inserted through the distal incision into the submuscular tunnel and fixed. A CT angiogram with 3D reconstruction was made to determine the distance from and location of the plate relative to the femoral artery and surgical dissection was done to identify the structures at risk. Results: No disruptions of superficial or deep femoral arteries were found. The closest distances from the superficial femoral artery and deep femoral artery to the plate were 8.3-27.2 mm (average 16.3 mm) (99% CI: 12.7-19.9) at the level 3 and 4.5-20.0 mm (average 8.6 mm) (99% CI: 6.4-10.9) at the level 2 in the proximal part of femur, respectively. The location where the SFA crossed the anterior cortex of the femur in the sagittal plane was 9.7-36.0% of the femoral length (average 20.1%) (99% CI: 15.0-25.3%) and the posterior cortex of the femur was 24.7-55.3% of the femoral length (average 40.8%) (99% CI: 35.0-46.7%). The location where the DFA crossed the anterior cortex of the femur in the sagittal plane was 7.9-25.3% of the femoral length (average 13.4%) (99% CI: 10.6-16.3%) and where it crossed the posterior cortex of the femur was 21.7-39.4% of the femoral length (average 31.2%) (99% CI: 27.1-33.3%). Conclusion: MIPO of the femur via medial approach is a feasible option for treatment of femoral fractures when the lateral approach is contraindicated. The distal 60% of the femoral length is safe for this approach. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2170 / 2176
页数:7
相关论文
共 50 条
  • [1] Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur
    Krettek, C
    Müller, M
    Miclau, T
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 14 - 23
  • [2] The Safety and Feasibility of Minimal Invasive Plate Osteosynthesis (MIPO) of the Posterior Aspect of the Humerus: A Cadaveric Study
    Jiamton, C.
    Ratreprasatsuk, N.
    Jarayabhand, R.
    Kritsaneephaiboon, A.
    Apivatthakakul, T.
    CLINICAL ANATOMY, 2019, 32 (02) : 176 - 182
  • [3] Minimally Invasive Plate Osteosynthesis (MIPO) Through the Posterior Approach for the Humerus: A Cadaveric Study
    Singh, Adhish P.
    Chauhan, Vijendra D.
    Kumar, Sanad
    Singh, Deepa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [4] Minimally invasive plate osteosynthesis (MIPO) for distal humeral fractures: a cadaveric study and first clinical application
    Hofmann, Valeska
    Diepold, Julian
    Moursy, Mohamed
    Birke, Marco T. T.
    Deininger, Christian
    Wichlas, Florian
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [5] Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture - Is it possible? A cadaveric study and preliminary report
    Apivatthakakul, T
    Arpornchayanon, O
    Bavornratanavech, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (04): : 530 - 538
  • [6] Minimally invasive plate osteosynthesis (MIPO) for distal humeral fractures: a cadaveric study and first clinical application
    Valeska Hofmann
    Julian Diepold
    Mohamed Moursy
    Marco T. Birke
    Christian Deininger
    Florian Wichlas
    BMC Musculoskeletal Disorders, 24
  • [7] Minimally invasive plate osteosynthesis (MIPO) for scapular fractures
    van de Wall, B. J. M.
    Hoepelman, R. J.
    Michelitsch, C.
    Diwersi, N.
    Sommer, C.
    Babst, R.
    Beeres, F. J. P.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (06): : 390 - 396
  • [8] Anteromedial minimally invasive plate osteosynthesis (MIPO) for distal third humeral shaft fractures - Is it possible?: A cadaveric study
    Buranaphatthana, T.
    Apivatthakakul, T.
    Apivatthakakul, V
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (06): : 1166 - 1174
  • [9] Danger zone for screw placement in minimally invasive plate osteosynthesis (MIPO) of diaphyseal fractures of forearm: a cadaveric study
    Apipop Kritsaneephaiboon
    Watit Wuttimanop
    Surasak Jitprapaikulsarn
    Pornpanit Dissaneewate
    Chulin Chewakidakarn
    Wich Orapiriyakul
    International Orthopaedics, 2021, 45 : 2111 - 2119
  • [10] Danger zone for screw placement in minimally invasive plate osteosynthesis (MIPO) of diaphyseal fractures of forearm: a cadaveric study
    Kritsaneephaiboon, Apipop
    Wuttimanop, Watit
    Jitprapaikulsarn, Surasak
    Dissaneewate, Pornpanit
    Chewakidakarn, Chulin
    Orapiriyakul, Wich