Temperature of Connections During Fire on Steel Framed Building

被引:6
|
作者
Chlouba, Jiri [1 ]
Wald, Frantiek [1 ]
Sokol, Zdenek [1 ]
机构
[1] Czech Tech Univ, Dept Steel & Timber Struct, CZ-16629 Prague, Czech Republic
关键词
fire design; connections; fire test; temperature; eurocodes;
D O I
10.1007/BF03249479
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the global structural and thermal behaviour of buildings in fire, a research project was conducted including a full-scale test on a three storey steel frame building at Mittal Steel Ostrava before demolition. The main goal of the experiment was to verify the method for predicting joint temperatures and to improve it for the cooling phase. The fire compartment extending over a floor area of 24 m(2) was built on the second floor. The fire load was 140 kg/m(2) of wood and the ventilation was limited to an opening of 1,400x 1,970 mm. This paper presents the time-temperature curves showing the development of the fire in the compartment and in the primary and secondary beams and its header plate connections. Comparisons are made between the test results and the temperatures predicted by the structural Eurocodes. The sensitivity of the connection behaviour to the estimated temperatures and associated degradation in material properties during the fire is demonstrated.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 50 条
  • [41] Fire load in a steel building design
    Razdolsky, L.
    INNOVATIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, VOLS 1 AND 2, 2008, : 1163 - 1167
  • [42] Special Issue on Response of Composite Steel Framed Structures to Fire - Preface
    Drysdale, DD
    FIRE SAFETY JOURNAL, 2001, 36 (08) : 719 - 720
  • [43] Influence of fire scenarios on progressive collapse mechanisms of steel framed structures
    Jiang, Jian
    Li, Guo-Qiang
    Usmani, Asif
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2014, 7 (03): : 169 - 172
  • [44] Fire resistance of steel-framed multi-storey buildings
    Wang, YC
    Moore, DB
    Lennon, T
    Cooke, GME
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 287 - 293
  • [45] Overall stability analysis of oversized steel-framed buildings in a fire
    Zhang, Guowei
    Zhu, Guoqing
    Yuan, Guanglin
    Li, Qing
    FIRE AND MATERIALS, 2016, 40 (02) : 273 - 288
  • [46] Effect of transient creep on fire induced instability in steel framed structures
    Venkatachari, S.
    Kodur, V.K.R.
    Journal of Constructional Steel Research, 2021, 181
  • [47] Effect of transient creep on fire induced instability in steel framed structures
    Venkatachari, S.
    Kodur, V. K. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [48] Rated typed Connections in Steel Building Construction
    不详
    BAUINGENIEUR, 2015, 90 : A10 - A10
  • [49] A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building
    Wang, Y.
    Dong, Y. -L.
    Li, B.
    Zhou, G. -C.
    FIRE SAFETY JOURNAL, 2013, 61 : 232 - 242
  • [50] Experimental study on fire resistance of a full-scale composite floor assembly in a two-story steel framed building
    Choe, Lisa
    Ramesh, Selvarajah
    Dai, Xu
    Hoehler, Matthew
    Bundy, Matthew
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (02) : 145 - 161