Fire resistance of steel-framed multi-storey buildings

被引:1
|
作者
Wang, YC
Moore, DB
Lennon, T
Cooke, GME
机构
关键词
fire resistance; whole building behaviour; fire testing of whole buildings; structural analysis at elevated temperature; tensile membrane action; fire resistant design;
D O I
10.1016/B978-008042830-7/50046-2
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Temperatures in unprotected steel elements of a building rise rapidly under fire conditions. These increases in steel temperatures are accompanied by sharp reductions in strength and stiffness. Consequently, regulatory authorities require fire protection to structural steel elements to achieve a required fire resistance with the intention of ensuring the stability of the steel structures under fire conditions. This paper provides a brief description of the developments in the fire resistance of steel framed multi-storey buildings, specifically the investigations undertaken at the UK's Building Research Establishment. The design of steel frames in multi-storey buildings for fire resistance is moving away from the traditional prescriptive method of fulfilling the requirements of building regulations to being performance based, ie. based on the understanding of the fire behaviour, the structural behaviour and requirement under fire conditions. This paper concludes with the suggestion that fire protection to steel beams in most multi-storey steel framed buildings may be eliminated, The reason is that the floor slabs have inherently sufficient load carrying capacities via the mechanism of tensile membrane action at large deflections.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [1] Fire design of multi-storey steel-framed buildings considering realistic natural fires
    Zehfuss, J
    Hosser, D
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 601 - 605
  • [2] Multi-storey steel-framed buildings with composite slab flooring: finite element modelling of fire behaviour
    Breunese, AJ
    Twilt, L
    Fellinger, JHH
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 629 - 633
  • [3] Structural Fire Analysis of One-storey Steel-framed Buildings with Steel Claddings
    Ma, Zhongcheng
    Havula, Jarmo
    Mela, Kristo
    Kesti, Jyrki
    ce/papers, 2021, 4 (2-4) : 1213 - 1222
  • [4] Fire behaviour of continuous reinforced concrete slabs in a full-scale multi-storey steel-framed building
    Li, B.
    Dong, Y. -L.
    Zhang, D. -S.
    FIRE SAFETY JOURNAL, 2015, 71 : 226 - 237
  • [5] Behavior of steel-framed buildings in a fire
    Al-Jabri, Khalifa S.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2007, 7 (03) : 227 - 237
  • [6] Behaviour of a multi-storey steel framed building subjected to fire attack
    O'Connor, M.A.
    Martin, D.M.
    Journal of Constructional Steel Research, 1998, 46 (1-3):
  • [7] Fire tests on two-way concrete, slabs in a full-scale multi-storey steel-framed building
    Yang, Z. N.
    Dong, Y. L.
    Xu, W. J.
    FIRE SAFETY JOURNAL, 2013, 58 : 38 - 48
  • [8] Fire protection demands for multi-storey steel buildings in seismic areas
    Vayas, I.
    Adamopoulou, S.
    Ziogos, P.
    STEEL - A NEW AND TRADITIONAL MATERIAL FOR BUILDING, 2006, : 567 - +
  • [9] Behaviour of Braced and Unbraced Multi-storey Steel Framed Buildings on Flat and Sloping Terrain
    Dey, Palash
    Wahengbam, Sylvia
    Gazi, Ainal Hoque
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2024, 24 (04) : 758 - 776
  • [10] Reusability of components from single-storey steel-framed buildings
    Hradil, Petr
    Fulop, Ludovic
    Ungureanu, Viorel
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2019, 12 (02): : 91 - 97