On-line monitoring of the photocatalytic degradation of 2,4-D and dicamba using a solid-phase extraction-multisyringe flow injection system

被引:14
|
作者
Chavez-Moreno, Carmin [1 ]
Ferrer, Laura [2 ]
Hinojosa-Reyes, Laura [1 ]
Hernandez-Ramirez, Aracely [1 ]
Cerda, Victor [3 ]
Guzman-Mar, Jorge [1 ]
机构
[1] UANL, Fac Ciencias Quim, San Nicolas De Los Garza 66451, Nuevo Leon, Mexico
[2] Univ Balearic Isl, Lab Environm Radioact LaboRA, E-07122 Palma De Mallorca, Spain
[3] Univ Balearic Isl, Lab Environm Analyt Chem LQA, E-07122 Palma De Mallorca, Spain
关键词
Dicamba; 2,4-D; Photocatalytic degradation; TiO2; MSFIA system; On-line monitoring; LIQUID-CHROMATOGRAPHY; WATER; ACID; CONTAMINANTS; SUSPENSIONS; RESIDUES; STATE;
D O I
10.1016/j.jenvman.2013.08.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 mu g L-1 for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 mu g L-1 for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 mu g L-1 for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 mu g L-1 for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [21] On-line solid-phase extraction using a C18 minicolumn coupled to a flow injection system for determination of caffeine in green and roasted coffee beans
    Salinas-Vargas, Maria E.
    Canizares-Macias, Maria P.
    FOOD CHEMISTRY, 2014, 147 : 182 - 188
  • [22] ANALYSIS OF TRIFLURALIN, METHYL PARAOXON, METHYL PARATHION, FENVALERATE AND 2,4-D DIMETHYLAMINE IN POND WATER USING SOLID-PHASE EXTRACTION
    SWINEFORD, DM
    BELISLE, AA
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1989, 8 (06) : 465 - 468
  • [23] 3D printed device including disk-based solid-phase extraction for the automated speciation of iron using the multisyringe flow injection analysis technique
    Calderilla, Carlos
    Maya, Fernando
    Cerda, Victor
    Leal, Luz O.
    TALANTA, 2017, 175 : 463 - 469
  • [24] Sequential injection spectrophotometric analysis of nitrite in natural waters using an on-line solid-phase extraction and preconcentration method
    Miró, M
    Cladera, A
    Estela, JM
    Cerdà, V
    ANALYST, 2000, 125 (05) : 943 - 948
  • [25] Fast sequential injection determination of benzo[A]pyrene using variable angle fluorescence with on-line solid-phase extraction
    Erustes, JA
    Andrade-Eiroa, A
    Cladera, A
    Forteza, R
    Cerdà, V
    ANALYST, 2001, 126 (04) : 451 - 456
  • [26] On-line molecular imprinted solid-phase extraction flow-injection fluorescence sensor for determination of florfenicol in animal tissues
    Ge, Shenguang
    Yan, Mei
    Cheng, Xiaoliang
    Zhang, Congcong
    Yu, Jinghua
    Zhao, Peini
    Gao, Weigiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) : 615 - 619
  • [27] Flow-injection determination of phenylephrine hydrochloride in pharmaceutical dosage forms with on-line solid-phase extraction and spectrophotometric detection
    Knochen, M
    Giglio, J
    TALANTA, 2004, 64 (05) : 1226 - 1232
  • [28] Multi-syringe flow injection solid-phase extraction system for on-line simultaneous spectrophotometric determination of nitro-substituted phenol isomers
    Manera, Matias
    Miro, Manuel
    Estela, Jose Manuel
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2007, 582 (01) : 41 - 49
  • [29] Stability of parathion-methyl, methiocarb, DDT and 2,4-D in solid-phase extraction precolumns packed with a polymeric reversed phase
    Vera-Avila, LE
    Vazquez-Lira, JC
    Covarrubias-Herrera, R
    Garcia-Camacho, MP
    Nuñez-Gaytan, AM
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 77 (04) : 255 - 268
  • [30] Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis. Comparison of chemiluminescence and fluorescence detection
    Jitka Huclová
    Dalibor Šatínský
    Hana Sklenářová
    Rolf Karlíček
    Analytical and Bioanalytical Chemistry, 2003, 376 : 448 - 454