Fast sequential injection determination of benzo[A]pyrene using variable angle fluorescence with on-line solid-phase extraction

被引:37
|
作者
Erustes, JA
Andrade-Eiroa, A
Cladera, A
Forteza, R
Cerdà, V
机构
[1] Univ Balearic Isl, Dept Chem, E-07071 Palma de Mallorca, Spain
[2] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
关键词
D O I
10.1039/b010129j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A methodology for the analysis of drinking water for one of the most potent carcinogenic agents known; benzo[a]pyrene (BaP), in the presence of other interfering PAHs is presented. The methodology described is based on the sequential injection analysis of the sample on to a microcolumn (containing 5 mg of C-18) where extraction and preconcentration of BaP takes place, followed by elution of BaP with 1 ml of 1,4-dioxane and subsequent detection by using variable angle fluorescence. The advantages of the method include the small amount of stationary phase employed together with the possibility of re-using the phase in order to carry out a large number of injections without the need for column re-packing. Also noteworthy is the small volume of 1,4-dioxane used to elute the BaP retained on the column and the small sample volumes required (9-10 ml) for achieving detection limits at the ng 1(-1) level. Thus, a methodology for BaP determination is obtained which complies with the requirements of the 98/83/EC Directive which fixes a maximum admissible concentration for this pollutant in waters for public consumption of 10 ng 1(-1). The variable angle spectra obtained are further processed by means of the multiple linear regression technique. The detection limit for BaP is 2.5 ng 1(-1), and the linear range is between 7.5 and 280 ng 1(-1).
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [1] Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis. Comparison of chemiluminescence and fluorescence detection
    Jitka Huclová
    Dalibor Šatínský
    Hana Sklenářová
    Rolf Karlíček
    Analytical and Bioanalytical Chemistry, 2003, 376 : 448 - 454
  • [2] Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis.: Comparison of chemiluminescence and fluorescence detection
    Huclová, J
    Satínsky, D
    Sklenárová, H
    Karlícek, R
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) : 448 - 454
  • [3] Using on-line solid phase extraction for determination of amiloride in human urine by sequential injection technique
    Huclova, Jitka
    Satinsky, Dalibor
    Pavlicek, Ondrej
    Vedralova, Lucie
    Karlicek, Rolf
    ANALYTICA CHIMICA ACTA, 2006, 573 : 376 - 382
  • [4] ON-LINE MINI-COLUMN SOLID-PHASE EXTRACTION COUPLED WITH SEQUENTIAL INJECTION FOR THE DETERMINATION OF CADMIUM IN ENVIRONMENTAL SAMPLES
    Zhu, Guifen
    Wang, Haibo
    Gao, Xia
    Fan, Jing
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (03) : 320 - 330
  • [5] Sequential injection spectrophotometric analysis of nitrite in natural waters using an on-line solid-phase extraction and preconcentration method
    Miró, M
    Cladera, A
    Estela, JM
    Cerdà, V
    ANALYST, 2000, 125 (05) : 943 - 948
  • [6] Determination of PAH Benzo[a]anthracene, Chrysene, Benzo[b]flouranthene and Benzo[a]pyrene in Hydro Alcoholic Herbal Extracts with Fluorescence Detector Using Solid-Phase Extraction
    Benny, Antony Merina
    Benny, Antony
    Aravind, E. S.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (02) : 148 - 153
  • [7] On-line molecular imprinted solid-phase extraction flow-injection fluorescence sensor for determination of florfenicol in animal tissues
    Ge, Shenguang
    Yan, Mei
    Cheng, Xiaoliang
    Zhang, Congcong
    Yu, Jinghua
    Zhao, Peini
    Gao, Weigiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) : 615 - 619
  • [8] Using on-line solid phase extraction for simultaneous determination of ascorbic acid and rutin trihydrate by sequential injection analysis
    Legnerová, Z
    Satínsky, D
    Solich, P
    ANALYTICA CHIMICA ACTA, 2003, 497 (1-2) : 165 - 174
  • [9] On-line solid-phase extraction and determination of paclitaxel in human plasma
    Mader, RM
    Rizovski, B
    Steger, GG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02): : 357 - 361
  • [10] On-line preconcentration and determination of tetracycline residues in milk using solid-phase extraction in conjunction with flow injection spectrophotometry
    Masawat, Prinya
    Mekprayoon, Sutthinee
    Liawruangrath, Saisunee
    Upalee, Suphachock
    Youngvises, Napaporn
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2008, 2 (02) : 418 - 430