Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa

被引:25
|
作者
Chibel, Ron [1 ,2 ]
Sher, Ifat [1 ,2 ]
Ben Ner, Daniel [1 ,2 ]
Mhajna, Mohamad O. [1 ]
Achiron, Asaf [3 ]
Hajyahia, Soad [1 ]
Skaat, Alon [1 ,2 ]
Berchenko, Yakir [4 ]
Oberman, Bernice [4 ]
Kalter-Leibovici, Ofra [2 ,5 ]
Freedman, Laurence [4 ]
Rotenstreich, Ygal [1 ,2 ]
机构
[1] Sheba Med Ctr, Goldschleger Eye Inst, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Wolfson Med Ctr, Dept Ophthalmol, Holon, Israel
[4] Gertner Inst Epidemiol & Hlth Policy Res, Biostat Unit, Ramat Gan, Israel
[5] Gertner Inst Epidemiol & Hlth Policy Res, Unit Cardiovasc Epidemiol, Ramat Gan, Israel
关键词
VISUAL-FIELD SENSITIVITY; PUPIL CAMPIMETRY; GLAUCOMA DETECTION; NORMAL EYES; RATES; ELECTRORETINOGRAM; VARIABILITY; THRESHOLD; STANDARD; REFLEX;
D O I
10.1016/j.ophtha.2016.05.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual field (VF) defects and retinal function objectively in healthy participants and patients with retinitis pigmentosa (RP) using a chromatic multifocal pupillometer. Design: Cross-sectional study. Participants: The right eyes of 16 healthy participants and 13 RP patients. Methods: Pupil responses to red and blue light (peak, 485 and 625 nm, respectively) presented by 76 light-emitting diodes, 1.8-mm spot size at different locations of a 16.2 degrees VF were recorded. Subjective VFs of RP patients were determined using chromatic dark-adapted Goldmann VFs (CDA-GVFs). Six healthy participants underwent 2 pupillometer examinations to determine test-retest reliability. Main Outcome Measures: Three parameters of pupil contraction were determined automatically: percentage of change of pupil size (PPC), maximum contraction velocity (MCV; in pixels per second), and latency of MCV (LMCV; in seconds). The fraction of functional VF was determined by CDA-GVF. Results: In healthy participants, higher PPC and MCV were measured in response to blue compared with red light. The LMCV in response to blue light was relatively constant throughout the VF. Healthy participants demonstrated higher PPC and MCV and shorter LMCV in central compared with peripheral test points in response to red light. Test-retest correlation coefficients were 0.7 for PPC and 0.5 for MCV. In RP patients, test point in which the PPC and MCV were lower than 4 standard errors from the mean of healthy participants correlated with areas that were indicated as nonseeing by CDA-GVF. The mean absolute deviation in LMCV parameter in response to the red light between different test point was significantly higher in RP patients (range, 0.16-0.47) than in healthy participants (range, 0.02-0.16; P < 0.0001) and indicated its usefulness as a diagnostic tool with high sensitivity and specificity (area under the receiver operating characteristic curve (AUC), 0.97, Mann-Whitney-Wilcoxon analysis). Randomly reducing the number of test points to a total of 15 points did not significantly reduce the AUC in RP diagnosis based on this parameter. Conclusions: This study demonstrates the feasibility of using a chromatic multifocal pupillometer for objective diagnosis of RP and assessment of VF defects. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:1898 / 1911
页数:14
相关论文
共 50 条
  • [41] The effect of cataract on accumap multifocal objective perimetry
    Whitehouse, GM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (01) : 209 - 212
  • [42] Diagnostic power of multifocal objective perimetry in concussion
    Rohan, Emilie Marie Francoise
    Carle, Corinne
    Maddess, Ted
    van Kleef, Josh
    Rai, Bhim Bahadur
    Sabeti, Faran
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [43] Clinical Characteristics at Initial Diagnosis of Korean Patients with Retinitis Pigmentosa
    Hwang, Jae Hyeong
    Nah, Seung Kwan
    Lew, Young Ju
    Kim, Chul Gu
    Kim, Jong Woo
    Kim, Jae Hui
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (04): : 352 - 360
  • [44] Visual acuity and 10° automated static perimetry in eyes with retinitis pigmentosa
    Abe, K
    Iijima, H
    Hirakawa, H
    Tsukahara, Y
    Toda, Y
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (05) : 581 - 585
  • [45] Test–retest reliability of the multifocal electroretinogram and Humphrey visual fields in patients with retinitis pigmentosa
    William Seiple
    Colleen J. Clemens
    Vivienne C. Greenstein
    Ronald E. Carr
    Karen Holopigian
    Documenta Ophthalmologica, 2004, 109 : 255 - 272
  • [46] Long-term follow-up of retinitis pigmentosa patients with multifocal electroretinography
    Nagy, Ditta
    Schoenfisch, Birgitt
    Zrenner, Eberhart
    Jaegle, Herbert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4664 - 4671
  • [47] Multifocal visual evoked potentials to cone specific stimuli in patients with retinitis pigmentosa (RP)
    Shuwairi, SM
    Holopigian, K
    Greenstein, VC
    Zhang, X
    Hood, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U271 - U271
  • [48] Pupillary responses evoked by chromatic stimulus in objective perimetry
    Tapia, J
    Suaste, E
    HUMAN VISION AND ELECTRONIC IMAGING IV, 1999, 3644 : 598 - 605
  • [49] Assessment of retinal function in patients with hiv without infectious retinitis by multifocal electroretinogram and automated perimetry
    Falkenstein, Iryna
    Kozak, Igor
    Kayikcioglu, Ozcan
    Cheng, Lingyun
    Bartsch, Dirk U.
    Azen, Stanley P.
    Labree, Laurie D.
    Freeman, William R.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (08): : 928 - 934
  • [50] Clustered Volleys Stimulus Presentation for Multifocal Objective Perimetry
    Carle, Corinne F.
    James, Andrew C.
    Sabeti, Faran
    Kolic, Maria
    Essex, Rohan W.
    Shean, Chris
    Jeans, Rhiannon
    Saikal, Aiasha
    Licinio, Alice
    Maddess, Ted
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (02):