Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa

被引:25
|
作者
Chibel, Ron [1 ,2 ]
Sher, Ifat [1 ,2 ]
Ben Ner, Daniel [1 ,2 ]
Mhajna, Mohamad O. [1 ]
Achiron, Asaf [3 ]
Hajyahia, Soad [1 ]
Skaat, Alon [1 ,2 ]
Berchenko, Yakir [4 ]
Oberman, Bernice [4 ]
Kalter-Leibovici, Ofra [2 ,5 ]
Freedman, Laurence [4 ]
Rotenstreich, Ygal [1 ,2 ]
机构
[1] Sheba Med Ctr, Goldschleger Eye Inst, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Wolfson Med Ctr, Dept Ophthalmol, Holon, Israel
[4] Gertner Inst Epidemiol & Hlth Policy Res, Biostat Unit, Ramat Gan, Israel
[5] Gertner Inst Epidemiol & Hlth Policy Res, Unit Cardiovasc Epidemiol, Ramat Gan, Israel
关键词
VISUAL-FIELD SENSITIVITY; PUPIL CAMPIMETRY; GLAUCOMA DETECTION; NORMAL EYES; RATES; ELECTRORETINOGRAM; VARIABILITY; THRESHOLD; STANDARD; REFLEX;
D O I
10.1016/j.ophtha.2016.05.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual field (VF) defects and retinal function objectively in healthy participants and patients with retinitis pigmentosa (RP) using a chromatic multifocal pupillometer. Design: Cross-sectional study. Participants: The right eyes of 16 healthy participants and 13 RP patients. Methods: Pupil responses to red and blue light (peak, 485 and 625 nm, respectively) presented by 76 light-emitting diodes, 1.8-mm spot size at different locations of a 16.2 degrees VF were recorded. Subjective VFs of RP patients were determined using chromatic dark-adapted Goldmann VFs (CDA-GVFs). Six healthy participants underwent 2 pupillometer examinations to determine test-retest reliability. Main Outcome Measures: Three parameters of pupil contraction were determined automatically: percentage of change of pupil size (PPC), maximum contraction velocity (MCV; in pixels per second), and latency of MCV (LMCV; in seconds). The fraction of functional VF was determined by CDA-GVF. Results: In healthy participants, higher PPC and MCV were measured in response to blue compared with red light. The LMCV in response to blue light was relatively constant throughout the VF. Healthy participants demonstrated higher PPC and MCV and shorter LMCV in central compared with peripheral test points in response to red light. Test-retest correlation coefficients were 0.7 for PPC and 0.5 for MCV. In RP patients, test point in which the PPC and MCV were lower than 4 standard errors from the mean of healthy participants correlated with areas that were indicated as nonseeing by CDA-GVF. The mean absolute deviation in LMCV parameter in response to the red light between different test point was significantly higher in RP patients (range, 0.16-0.47) than in healthy participants (range, 0.02-0.16; P < 0.0001) and indicated its usefulness as a diagnostic tool with high sensitivity and specificity (area under the receiver operating characteristic curve (AUC), 0.97, Mann-Whitney-Wilcoxon analysis). Randomly reducing the number of test points to a total of 15 points did not significantly reduce the AUC in RP diagnosis based on this parameter. Conclusions: This study demonstrates the feasibility of using a chromatic multifocal pupillometer for objective diagnosis of RP and assessment of VF defects. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:1898 / 1911
页数:14
相关论文
共 50 条
  • [11] Dark-Adapted Chromatic Perimetry for Measuring Rod Visual Fields in Patients with Retinitis Pigmentosa
    Bennett, Lea D.
    Klein, Martin
    Locke, Kirsten G.
    Kiser, Kelly
    Birch, David G.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (04):
  • [12] Chromatic multifocal pupilloperimetry for objective perimetry in retinal and optic nerve neurodegeneration
    Sher-Rosenthal, Ifat
    Gurevich, Maya
    Rotenstreich, Ygal
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [13] COMPUTERIZED PERIMETRY IN RETINITIS-PIGMENTOSA
    PERDICCHI, A
    PANNARALE, L
    AMODEO, S
    RISPOLI, M
    VINGOLO, EM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2159 - 2159
  • [14] Flicker perimetry in retinitis pigmentosa.
    Paranhos, FRI
    Nehemy, MB
    Arai, M
    Hirose, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S890 - S890
  • [15] Multifocal electroretinography in retinitis pigmentosa
    Seeliger, M
    Kretschmann, U
    Apfelstedt-Sylla, E
    Rüther, K
    Zrenner, E
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (02) : 214 - 226
  • [16] Intersession repeatability of humphrey perimetry measurements in patients with retinitis pigmentosa
    Kim, Linda S.
    McAnany, J. Jason
    Alexander, Kenneth R.
    Fishman, Gerald A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (10) : 4720 - 4724
  • [17] Chromatic multifocal pupillometry for objective perimetry in patients with Best's vitelliform macular dystrophy (Conference Presentation)
    Rotenstreich, Ygal
    Ben-Ner, Daniel
    Chibel, Ron
    Mahajna, Mohamad O.
    Sher, Ifat
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [18] Assessing migraine patients with multifocal pupillographic objective perimetry
    Eman N. Ali
    Corinne F. Carle
    Christian J. Lueck
    Maria Kolic
    Ted Maddess
    BMC Neurology, 21
  • [19] Multifocal electroretinography in segmental retinitis pigmentosa
    Palmowski, AM
    Allgayer, R
    Heinemann-Vernaleken, B
    Scherer, V
    Eich, W
    Ruprecht, KW
    OPHTHALMOLOGE, 2001, 98 (03): : 294 - 299
  • [20] Assessing migraine patients with multifocal pupillographic objective perimetry
    Ali, Eman N.
    Carle, Corinne F.
    Lueck, Christian J.
    Kolic, Maria
    Maddess, Ted
    BMC NEUROLOGY, 2021, 21 (01)