Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa

被引:25
|
作者
Chibel, Ron [1 ,2 ]
Sher, Ifat [1 ,2 ]
Ben Ner, Daniel [1 ,2 ]
Mhajna, Mohamad O. [1 ]
Achiron, Asaf [3 ]
Hajyahia, Soad [1 ]
Skaat, Alon [1 ,2 ]
Berchenko, Yakir [4 ]
Oberman, Bernice [4 ]
Kalter-Leibovici, Ofra [2 ,5 ]
Freedman, Laurence [4 ]
Rotenstreich, Ygal [1 ,2 ]
机构
[1] Sheba Med Ctr, Goldschleger Eye Inst, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Wolfson Med Ctr, Dept Ophthalmol, Holon, Israel
[4] Gertner Inst Epidemiol & Hlth Policy Res, Biostat Unit, Ramat Gan, Israel
[5] Gertner Inst Epidemiol & Hlth Policy Res, Unit Cardiovasc Epidemiol, Ramat Gan, Israel
关键词
VISUAL-FIELD SENSITIVITY; PUPIL CAMPIMETRY; GLAUCOMA DETECTION; NORMAL EYES; RATES; ELECTRORETINOGRAM; VARIABILITY; THRESHOLD; STANDARD; REFLEX;
D O I
10.1016/j.ophtha.2016.05.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual field (VF) defects and retinal function objectively in healthy participants and patients with retinitis pigmentosa (RP) using a chromatic multifocal pupillometer. Design: Cross-sectional study. Participants: The right eyes of 16 healthy participants and 13 RP patients. Methods: Pupil responses to red and blue light (peak, 485 and 625 nm, respectively) presented by 76 light-emitting diodes, 1.8-mm spot size at different locations of a 16.2 degrees VF were recorded. Subjective VFs of RP patients were determined using chromatic dark-adapted Goldmann VFs (CDA-GVFs). Six healthy participants underwent 2 pupillometer examinations to determine test-retest reliability. Main Outcome Measures: Three parameters of pupil contraction were determined automatically: percentage of change of pupil size (PPC), maximum contraction velocity (MCV; in pixels per second), and latency of MCV (LMCV; in seconds). The fraction of functional VF was determined by CDA-GVF. Results: In healthy participants, higher PPC and MCV were measured in response to blue compared with red light. The LMCV in response to blue light was relatively constant throughout the VF. Healthy participants demonstrated higher PPC and MCV and shorter LMCV in central compared with peripheral test points in response to red light. Test-retest correlation coefficients were 0.7 for PPC and 0.5 for MCV. In RP patients, test point in which the PPC and MCV were lower than 4 standard errors from the mean of healthy participants correlated with areas that were indicated as nonseeing by CDA-GVF. The mean absolute deviation in LMCV parameter in response to the red light between different test point was significantly higher in RP patients (range, 0.16-0.47) than in healthy participants (range, 0.02-0.16; P < 0.0001) and indicated its usefulness as a diagnostic tool with high sensitivity and specificity (area under the receiver operating characteristic curve (AUC), 0.97, Mann-Whitney-Wilcoxon analysis). Randomly reducing the number of test points to a total of 15 points did not significantly reduce the AUC in RP diagnosis based on this parameter. Conclusions: This study demonstrates the feasibility of using a chromatic multifocal pupillometer for objective diagnosis of RP and assessment of VF defects. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:1898 / 1911
页数:14
相关论文
共 50 条
  • [31] Multifocal objective perimetry compared with Humphrey full-threshold perimetry in patients with optic neuritis
    Pakrou, Nima
    Casson, Robert
    Kaines, Andrew
    Selva, Dinesh
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 562 - 567
  • [32] A Preliminary Evaluation of a Pupillometer-Based Objective Chromatic Primetry
    Skaat, A.
    Kolker, A.
    Melamed, S.
    Belkin, M.
    Rotenstreich, Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] A comparison of multifocal and full-field photopic electroretinograms in patients with retinitis pigmentosa
    Wynn, P
    Holopigian, K
    Carr, RE
    Hood, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U576 - U576
  • [34] Reliability of multifocal electroretinograms and Humphrey visual field thresholds in patients with retinitis pigmentosa
    Clemens, CJ
    Seiple, W
    Holopigian, K
    Carr, RE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U577 - U577
  • [35] The Multifocal Electroretinograms and Optical Coherence Tomography Findings in Advanced Retinitis Pigmentosa Patients
    Jang, S.
    Ohn, Y. -H.
    Park, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] Multifocal visual evoked potentials to cone specific stimuli in patients with retinitis pigmentosa
    Holopigian, K
    Shuwairi, SM
    Greenstein, VC
    Winn, BJ
    Zhang, X
    Carr, RE
    Hood, DC
    VISION RESEARCH, 2005, 45 (25-26) : 3244 - 3252
  • [37] Assessing concussion with multifocal pupillographic objective perimetry
    Maddess, Ted
    Jaros, Rachel
    Sabeti, Faran
    Rohan, Emilie
    Carle, Corinne F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [38] Principal components' analysis of multifocal electroretinogram in retinitis pigmentosa
    Maiti, Aniruddha
    Uparkar, Mahesh
    Natarajan, Sundaram
    Borse, Nishikanth
    Walinjkar, Jaydeep
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2011, 59 (05) : 353 - 357
  • [39] Blue Multifocal Pupillographic Objective Perimetry in Glaucoma
    Carle, Corinne F.
    James, Andrew C.
    Kolic, Maria
    Essex, Rohan W.
    Maddess, Ted
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (11) : 6394 - 6403
  • [40] Stimulus Parameters for Multifocal Pupillographic Objective Perimetry
    James, Andrew Charles
    Kolic, Maria
    Bedford, Suzanne Margaret
    Maddess, Ted
    JOURNAL OF GLAUCOMA, 2012, 21 (09) : 571 - 578