Dynamical time focus shift in multiple-reflection time-of-flight mass spectrometers

被引:31
|
作者
Dickel, Timo [1 ,2 ]
Yavor, Mikhail I. [3 ]
Lang, Johannes [1 ]
Plass, Wolfgang R. [1 ,2 ]
Lippert, Wayne [1 ]
Geissel, Hans [1 ,2 ]
Scheidenberger, Christoph [1 ,2 ]
机构
[1] Justus Liebig Univ Giessen, Phys Inst 2, D-35392 Giessen, Germany
[2] GSI Helmholtzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany
[3] Russian Acad Sci, Inst Analyt Instrumentat, St Petersburg 190103, Russia
关键词
Multiple-reflection time-of-flight mass spectrometer; Time focus; Ion reflector; Isochronicity; HIGH-RESOLUTION; SEPARATION; BEAM; ANALYZER; ISOTOPES; NUCLEI; MODE;
D O I
10.1016/j.ijms.2016.11.005
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A new method is presented for making the overall flight path of ions in a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) isochronous. Here, the ions undergo an arbitrary number of turns in a TOF analyzer, which itself is tuned to be isochronous from turn to turn. The overall isochronicity from the ion source or injection trap to the detector is established by changing the voltage settings of the analyzer dynamically to a different mode for one turn. This approach combines the advantages of an MR-TOF-MS with a time focus shift reflector with the simplicity of an MR-TOF-MS with only the TOF analyzer as an isochronous tool. Measurements have been performed, in which an MR-TOF-MS was operated with this dynamical time focus shift. These are compared to measurements, in which the time focus was shifted onto the detector using a variation of the extraction field strength in the injection trap. A mass resolving power was achieved that is up to three times larger for the same time-of-flight. For Cs ions, mass resolving powers of 100,000 and 200,000 were obtained after flight times of 1.7 ms and 4.9 ms, respectively. These flight times are a factor of 3 shorter than those with the time focus shift with the injection trap. The smaller number of turns required for a given mass resolving power results in a larger unambiguous mass range, a higher transmission efficiency, a higher ion capacity and a shorter measurement time. This yields advantages in precision experiments in nuclear physics and for applications in analytical mass spectrometry. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Multiple-reflection time-of-flight mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 134 - 144
  • [2] Multiple-reflection time-of-flight mass spectrometry for in situ applications
    Dickel, T.
    Plass, W. R.
    Lang, J.
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Lippert, W.
    Petrick, M.
    Scheidenberger, C.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 779 - 784
  • [3] High-performance multiple-reflection time-of-flight mass spectrometers for research with exotic nuclei and for analytical mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    San Andres, Samuel Ayet
    Ebert, Jens
    Greiner, Florian
    Hornung, Christine
    Jesch, Christian
    Lang, Johannes
    Lippert, Wayne
    Majoros, Tamas
    Short, Devin
    Geissel, Hans
    Haettner, Emma
    Reiter, Moritz P.
    Rink, Ann-Kathrin
    Scheidenberger, Christoph
    Yavor, Mikhail I.
    [J]. PHYSICA SCRIPTA, 2015, T166
  • [4] Recent upgrades of the multiple-reflection time-of-flight mass spectrometer at TITAN, TRIUMF
    Dickel, Timo
    San Andres, Samuel Ayet
    Beck, Soenke
    Bergmann, Julian
    Dilling, Jens
    Greiner, Florian
    Hornung, Christine
    Jacobs, Andrew
    Kripko-Koncz, Gabriella
    Kwiatkowski, Ania
    Leistenschneider, Erich
    Pikthtelev, Alexander
    Plass, Wolfgang R.
    Reiter, Moritz P.
    Scheidenberger, Christoph
    Will, Christian
    [J]. HYPERFINE INTERACTIONS, 2019, 240 (1):
  • [5] Design of a multiple-reflection time-of-flight mass spectrometer for barium-tagging
    K. Murray
    J. Dilling
    R. Gornea
    Y. Ito
    T. Koffas
    A. A. Kwiatkowski
    Y. Lan
    M. P. Reiter
    V. Varentsov
    T. Brunner
    [J]. Hyperfine Interactions, 2019, 240
  • [6] Recent upgrades of the multiple-reflection time-of-flight mass spectrometer at TITAN, TRIUMF
    Timo Dickel
    Samuel Ayet San Andrés
    Sönke Beck
    Julian Bergmann
    Jens Dilling
    Florian Greiner
    Christine Hornung
    Andrew Jacobs
    Gabriella Kripko-Koncz
    Ania Kwiatkowski
    Erich Leistenschneider
    Alexander Pikthtelev
    Wolfgang R. Plaß
    Moritz P. Reiter
    Christoph Scheidenberger
    Christian Will
    [J]. Hyperfine Interactions, 2019, 240
  • [7] Design of a multiple-reflection time-of-flight mass spectrometer for barium-tagging
    Murray, K.
    Dilling, J.
    Gornea, R.
    Ito, Y.
    Koffas, T.
    Kwiatkowski, A. A.
    Lan, Y.
    Reiter, M. P.
    Varentsov, V.
    Brunner, T.
    [J]. HYPERFINE INTERACTIONS, 2019, 240 (01):
  • [8] Unveiling nuclear isomers through multiple-reflection time-of-flight mass spectrometry
    Dickel, Timo
    Mollaebrahimi, Ali
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2024, 233 (05): : 1181 - 1190
  • [9] NONMAGNETIC TIME-OF-FLIGHT MASS SPECTROMETERS
    PAVLENKO, VA
    OZEROV, LN
    RAFALSON, AE
    [J]. SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1968, 13 (04): : 431 - &
  • [10] Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping
    Dickel, Timo
    Plass, Wolfgang R.
    Lippert, Wayne
    Lang, Johannes
    Yavor, Mikhail I.
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (06) : 1079 - 1090