摘要
A new method is presented for making the overall flight path of ions in a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) isochronous. Here, the ions undergo an arbitrary number of turns in a TOF analyzer, which itself is tuned to be isochronous from turn to turn. The overall isochronicity from the ion source or injection trap to the detector is established by changing the voltage settings of the analyzer dynamically to a different mode for one turn. This approach combines the advantages of an MR-TOF-MS with a time focus shift reflector with the simplicity of an MR-TOF-MS with only the TOF analyzer as an isochronous tool. Measurements have been performed, in which an MR-TOF-MS was operated with this dynamical time focus shift. These are compared to measurements, in which the time focus was shifted onto the detector using a variation of the extraction field strength in the injection trap. A mass resolving power was achieved that is up to three times larger for the same time-of-flight. For Cs ions, mass resolving powers of 100,000 and 200,000 were obtained after flight times of 1.7 ms and 4.9 ms, respectively. These flight times are a factor of 3 shorter than those with the time focus shift with the injection trap. The smaller number of turns required for a given mass resolving power results in a larger unambiguous mass range, a higher transmission efficiency, a higher ion capacity and a shorter measurement time. This yields advantages in precision experiments in nuclear physics and for applications in analytical mass spectrometry. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [41] ANGULAR AND TIME RESOLUTION OF NEUTRON TIME-OF-FLIGHT SPECTROMETERS
    CREVECOEUR, R
    DESCHEPPER, I
    DEGRAAF, L
    MONTFROOIJ, W
    SVENSSON, E
    CARLILE, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 356 (2-3): : 415 - 421
  • [42] Tandem and very high mass time-of-flight mass spectrometers for proteome research
    Cotter, Robert J.
    Iltchenko, Serguei
    Gundry, Rebekah
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S124 - S124
  • [43] Mass-correlated delayed extraction in linear time-of-flight mass spectrometers
    Kovtoun, SV
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (07) : 810 - 815
  • [44] Design of high performance time-of-flight (TOF) and tandem time-of-flight (TOF-TOF) mass spectrometers.
    Vestal, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U149 - U149
  • [45] THE EXPANDING ROLE OF TIME-OF-FLIGHT MASS SPECTROMETERS IN ANALYTICAL MASS-SPECTROMETRY
    RUSSELL, DH
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 113 - ANYL
  • [46] New technologies for time-of-flight and ion trap mass spectrometers.
    Cotter, RJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U89 - U89
  • [47] NEW METHOD FOR FOCUSING ION BUNCHES IN TIME-OF-FLIGHT MASS SPECTROMETERS
    KARATAEV, VI
    SHMIKK, DV
    MAMYRIN, BA
    [J]. SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1972, 16 (07): : 1177 - &
  • [48] Multi-turn time-of-flight mass spectrometers with electrostatic sectors
    Toyoda, M
    Okumura, D
    Ishihara, M
    Katakuse, I
    [J]. JOURNAL OF MASS SPECTROMETRY, 2003, 38 (11): : 1125 - 1142
  • [49] Detection and registration of ion clots in laser time-of-flight mass spectrometers
    Silnikov, E. E.
    Sysoev, Alexey A.
    Sysoev, Alexander A.
    Fatyushina, E. V.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2008, 51 (04) : 574 - 582
  • [50] Time-Of-Flight Mass Spectrometers Made in Switzerland: Examples of Mobile Applications
    Hutterli, Manuel A.
    Pospisilova, Veronika
    Gonin, Marc
    [J]. CHIMIA, 2022, 76 (1-2) : 60 - 67