High-performance multiple-reflection time-of-flight mass spectrometers for research with exotic nuclei and for analytical mass spectrometry

被引:19
|
作者
Plass, Wolfgang R. [1 ,2 ]
Dickel, Timo [1 ,2 ]
San Andres, Samuel Ayet [1 ,2 ]
Ebert, Jens [1 ]
Greiner, Florian [1 ]
Hornung, Christine [1 ]
Jesch, Christian [1 ]
Lang, Johannes [1 ]
Lippert, Wayne [1 ]
Majoros, Tamas [3 ]
Short, Devin [4 ]
Geissel, Hans [1 ,2 ]
Haettner, Emma [2 ]
Reiter, Moritz P. [1 ]
Rink, Ann-Kathrin [1 ]
Scheidenberger, Christoph [1 ,2 ]
Yavor, Mikhail I. [5 ]
机构
[1] Univ Giessen, Inst Phys 2, D-35392 Giessen, Germany
[2] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[3] Budapest Univ Technol & Econ, Dept Atom Phys, H-1111 Budapest, Hungary
[4] TRIUMF, Vancouver, BC V6T 2A3, Canada
[5] Russian Acad Sci, Inst Analyt Instrumentat, St Petersburg 198103, Russia
关键词
multiple-reflection time-of-flight mass spectrometer; isobar separator; direct mass measurement; exotic nuclei; mobile mass spectrometer; HIGH-PRECISION EXPERIMENTS; CRYOGENIC STOPPING CELL; ISOBAR-SEPARATION; SUPER-FRS; BEAM; FRAGMENTS; ISOTOPES; SYSTEM; IONS; FAIR;
D O I
10.1088/0031-8949/2015/T166/014069
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A class of multiple-reflection time-of-flight mass spectrometers (MR-TOF-MSs) has been developed for research with exotic nuclei at present and future accelerator facilities such as GSI and FAIR (Darmstadt), and TRIUMF (Vancouver). They can perform highly accurate mass measurements of exotic nuclei, serve as high-resolution, high-capacity mass separators and be employed as diagnostics devices to monitor the production, separation and manipulation of beams of exotic nuclei. In addition, a mobile high-resolution MR-TOF-MS has been developed for in situ applications in analytical mass spectrometry ranging from environmental research to medicine. Recently, the MR-TOF-MS for GSI and FAIR has been further developed. A novel RF quadrupole-based ion beam switchyard has been developed that allows merging and splitting of ion beams as well as transport of ions into different directions. It efficiently connects a test and reference ion source and an auxiliary detector to the system. Due to an increase in the kinetic energy of the ions in the time-of-flight analyzer of the MR-TOF-MS, a given mass resolving power is now achieved in less than half the time-of-flight. Conversely, depending on the time-of-flight, the mass resolving power has been increased by a factor of more than two.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A high-performance multiple-reflection time-of-flight mass spectrometer and isobar separator for the research with exotic nuclei
    Dickel, T.
    Plass, W. R.
    Becker, A.
    Czok, U.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Kinsel, W.
    Petrick, M.
    Scheidenberger, C.
    Simon, A.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 777 : 172 - 188
  • [2] Multiple-reflection time-of-flight mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 134 - 144
  • [3] Multiple-reflection time-of-flight mass spectrometry for in situ applications
    Dickel, T.
    Plass, W. R.
    Lang, J.
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Lippert, W.
    Petrick, M.
    Scheidenberger, C.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 779 - 784
  • [4] Dynamical time focus shift in multiple-reflection time-of-flight mass spectrometers
    Dickel, Timo
    Yavor, Mikhail I.
    Lang, Johannes
    Plass, Wolfgang R.
    Lippert, Wayne
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 412 : 1 - 7
  • [5] Unveiling nuclear isomers through multiple-reflection time-of-flight mass spectrometry
    Dickel, Timo
    Mollaebrahimi, Ali
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2024, 233 (05): : 1181 - 1190
  • [6] Ion-optical design of a high-performance multiple-reflection time-of-flight mass spectrometer and isobar separator
    Yavor, Mikhail I.
    Plass, Wolfgang R.
    Dickel, Timo
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 381 : 1 - 9
  • [7] THE EXPANDING ROLE OF TIME-OF-FLIGHT MASS SPECTROMETERS IN ANALYTICAL MASS-SPECTROMETRY
    RUSSELL, DH
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 113 - ANYL
  • [8] Time-of-flight mass measurements of exotic nuclei
    Matos, M.
    Estrade, A.
    Schatz, H.
    Bazin, D.
    Famiano, M.
    Gade, A.
    George, S.
    Lynch, W. G.
    Meisel, Z.
    Portillo, M.
    Rogers, A.
    Shapira, D.
    Stolz, A.
    Wallace, M.
    Yurkon, J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 696 : 171 - 179
  • [9] Recent upgrades of the multiple-reflection time-of-flight mass spectrometer at TITAN, TRIUMF
    Dickel, Timo
    San Andres, Samuel Ayet
    Beck, Soenke
    Bergmann, Julian
    Dilling, Jens
    Greiner, Florian
    Hornung, Christine
    Jacobs, Andrew
    Kripko-Koncz, Gabriella
    Kwiatkowski, Ania
    Leistenschneider, Erich
    Pikthtelev, Alexander
    Plass, Wolfgang R.
    Reiter, Moritz P.
    Scheidenberger, Christoph
    Will, Christian
    [J]. HYPERFINE INTERACTIONS, 2019, 240 (1):
  • [10] Design of a multiple-reflection time-of-flight mass spectrometer for barium-tagging
    K. Murray
    J. Dilling
    R. Gornea
    Y. Ito
    T. Koffas
    A. A. Kwiatkowski
    Y. Lan
    M. P. Reiter
    V. Varentsov
    T. Brunner
    [J]. Hyperfine Interactions, 2019, 240