Recent upgrades of the multiple-reflection time-of-flight mass spectrometer at TITAN, TRIUMF

被引:0
|
作者
Timo Dickel
Samuel Ayet San Andrés
Sönke Beck
Julian Bergmann
Jens Dilling
Florian Greiner
Christine Hornung
Andrew Jacobs
Gabriella Kripko-Koncz
Ania Kwiatkowski
Erich Leistenschneider
Alexander Pikthtelev
Wolfgang R. Plaß
Moritz P. Reiter
Christoph Scheidenberger
Christian Will
机构
[1] Justus Liebig Universität Gießen,II. Physikalisches Institut
[2] GSI Helmholtzzentrum für Schwerionenforschung GmbH,Institute for Energy Problems of Chemical Physics
[3] TRIUMF,undefined
[4] RAS,undefined
来源
Hyperfine Interactions | 2019年 / 240卷
关键词
Mass measurements; MR-TOF-MS; Exotic nuclides; Isomers; Instrument control; On- and offline data-analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been installed and integrated into the TITAN experiment at TRIUMF. The MR-TOF-MS extends the capabilities and improves the performance of the TITAN experiment, for instance it provides fast isobar separation, short measurement cycles, yield measurements and broad-band beam diagnosis, and enhanced rate capabilities and dynamic range. Thereby, even more exotic nuclides become accessible at TITAN for experiments. Such improved capabilities of TITAN have been used in first experiments to investigate the sub-shell closure of neutron-rich nuclides at N = 32 and the r-process nucleo-synthesis for masses at A ∼ 85. The vacuum system, electronics and data-acquisition hardware and software have been recently upgraded. For the first time an isomeric state has been measured with TITAN′s MR-TOF-MS, 84mRb (excitation energy: 464 keV). The accurate measurement of excitation energies of low-lying isomeric states is possible due to the high mass resolving power of TITAN′s MR-TOF-MS and a specialized data-analysis procedure.
引用
收藏
相关论文
共 50 条
  • [1] Recent upgrades of the multiple-reflection time-of-flight mass spectrometer at TITAN, TRIUMF
    Dickel, Timo
    San Andres, Samuel Ayet
    Beck, Soenke
    Bergmann, Julian
    Dilling, Jens
    Greiner, Florian
    Hornung, Christine
    Jacobs, Andrew
    Kripko-Koncz, Gabriella
    Kwiatkowski, Ania
    Leistenschneider, Erich
    Pikthtelev, Alexander
    Plass, Wolfgang R.
    Reiter, Moritz P.
    Scheidenberger, Christoph
    Will, Christian
    [J]. HYPERFINE INTERACTIONS, 2019, 240 (1):
  • [2] Commissioning and performance of TITAN's Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator
    Reiter, M. P.
    San Andres, S. Ayet
    Bergmann, J.
    Dickel, T.
    Dilling, J.
    Jacobs, A.
    Kwiatkowski, A. A.
    Plass, W. R.
    Scheidenberger, C.
    Short, D.
    Will, C.
    Babcock, C.
    Dunling, E.
    Finlay, A.
    Hornung, C.
    Jesch, C.
    Klawitter, R.
    Kootte, B.
    Lascar, D.
    Leistenschneider, E.
    Murboeck, T.
    Paul, S. F.
    Yavor, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1018
  • [3] Multiple-reflection time-of-flight mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 134 - 144
  • [4] Design of a multiple-reflection time-of-flight mass spectrometer for barium-tagging
    K. Murray
    J. Dilling
    R. Gornea
    Y. Ito
    T. Koffas
    A. A. Kwiatkowski
    Y. Lan
    M. P. Reiter
    V. Varentsov
    T. Brunner
    [J]. Hyperfine Interactions, 2019, 240
  • [5] Design of a multiple-reflection time-of-flight mass spectrometer for barium-tagging
    Murray, K.
    Dilling, J.
    Gornea, R.
    Ito, Y.
    Koffas, T.
    Kwiatkowski, A. A.
    Lan, Y.
    Reiter, M. P.
    Varentsov, V.
    Brunner, T.
    [J]. HYPERFINE INTERACTIONS, 2019, 240 (01):
  • [6] Multiple-reflection time-of-flight mass spectrometry for in situ applications
    Dickel, T.
    Plass, W. R.
    Lang, J.
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Lippert, W.
    Petrick, M.
    Scheidenberger, C.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 779 - 784
  • [7] Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping
    Dickel, Timo
    Plass, Wolfgang R.
    Lippert, Wayne
    Lang, Johannes
    Yavor, Mikhail I.
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (06) : 1079 - 1090
  • [8] Adaptive Online Optimization of Multiple-Reflection Time-of-Flight Mass Spectrometer Performance Based on Genetic Algorithm
    Zhang, Tao
    Chen, Yi
    Chen, Ping
    Cao, Yi-Xue
    Tian, Di
    Hua, Lei
    Li, Hai-Yang
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (07) : 1105 - 1111
  • [9] Dynamical time focus shift in multiple-reflection time-of-flight mass spectrometers
    Dickel, Timo
    Yavor, Mikhail I.
    Lang, Johannes
    Plass, Wolfgang R.
    Lippert, Wayne
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 412 : 1 - 7
  • [10] A high-performance multiple-reflection time-of-flight mass spectrometer and isobar separator for the research with exotic nuclei
    Dickel, T.
    Plass, W. R.
    Becker, A.
    Czok, U.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Kinsel, W.
    Petrick, M.
    Scheidenberger, C.
    Simon, A.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 777 : 172 - 188