摘要
This work presents an experimental analysis of the energy and environmental performance of low-GWP re-frigerants R513A, R1234yf and R436A as alternatives for R134a in a cascade refrigeration system that operates with R744 in low-temperature cycle. An apparatus was built using a well-insulated room, where tests were carried out in a steady state condition. In addition to the typical components of a cascade cycle, an intermediate heat exchanger was used to thermally communicate the low and high temperature cycles, thus providing additional superheating and subcooling, respectively. The cooling capacity of the system ranged from 2.2 to 3.8 kW, the evaporation temperature varied from-34 to-24.5 degrees C and the air temperature inside the cold room ranged from-23.1 to-9.4 degrees C. The results revealed that the alternative refrigerants are potential substitutes for R134a in cascade refrigeration systems, showing an average increase in the CRC coefficient of performance of 3.1% for R436A, while R1234yf and R513A exhibited a reduction of 3.7% and 4.4%, respectively. The environmental impact analysis considered the scenarios of Chicago (USA) and Curitiba (Brazil), the latter being a southern Brazilian city with a wet climate throughout the year, a warm and mostly cloudy summer, and a short and cold winter. Total TEWI values, compared to those obtained with the originally designed R134a system, showed reductions in CO2 equivalent emission of 46%, 42.1% and 22.5% for refrigerants R436A, R1234yf and R513A, respectively, for the Curitiba scenario, while the values for Chicago were increments of 0.3%, 2.4% and 5.8%, respectively.
引用
收藏
页码:175 / 187
页数:13
相关论文
共 50 条
  • [21] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [22] Optimal design and environmental, energy and exergy analysis of a vapor compression refrigeration system using R290, R1234yf, and R744 as alternatives to replace R134a
    de Paula, Cleison Henrique
    Duarte, Willian Moreira
    Martins Rocha, Thiago Torres
    de Oliveira, Raphael Nunes
    Torres Maia, Antonio Augusto
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 (113) : 10 - 20
  • [23] Thermodynamic analysis of usage of R134a, R1234yf, R450A, R513A and R515B in the mechanical vapor compression refrigeration system
    Bilen, Kemal
    Isik, Bilal
    Dagidir, Kayhan
    Arcaklioglu, Erol
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2024, 39 (01): : 161 - 175
  • [24] Thermodynamic analysis of usage of R134a, R1234yf, R450A, R513A, and R515B in the mechanical vapor compression refrigeration system
    Bilen K.
    Işık B.
    Dağıdır K.
    Arcaklıoğlu E.
    Journal of the Faculty of Engineering and Architecture of Gazi University, 2023, 39 (01): : 161 - 175
  • [25] Energy assessment and environmental impact analysis of an R134a/R744 cascade refrigeration plant upgraded with the low-GWP refrigerants R152a, R1234ze(E), propane (R290) and propylene (R1270)
    Sanchez, D.
    Cabello, R.
    Llopis, R.
    Catalan-Gil, J.
    Nebot-Andres, L.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 321 - 334
  • [26] Numerical Investigation During Condensation of R134a Inside a Smooth and Dimpled Tube: Comparison with low-GWP Alternatives R1234yf, R1234ze and R290
    N. V. S. M. Reddy
    K. Satyanarayana
    S. Venugopal
    Theoretical Foundations of Chemical Engineering, 2022, 56 : 791 - 801
  • [27] Numerical Investigation During Condensation of R134a Inside a Smooth and Dimpled Tube: Comparison with low-GWP Alternatives R1234yf, R1234ze and R290
    Reddy, N. V. S. M.
    Satyanarayana, K.
    Venugopal, S.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2022, 56 (05) : 791 - 801
  • [28] Experimental evaluation of a cascade refrigeration system with the natural refrigerants R290/R744, R1270/R744 and R600a/R744
    Cabello, R.
    Sanchez, D.
    Andreu-Nacher, A.
    Llopis, R.
    Nebot-Andres, L.
    Calleja-Anta, D.
    Vidan-Falomir, F.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 616 - 626
  • [29] Experimental assessment of R134a and its lower GWP alternative R513A
    Mota-Babiloni, Adrian
    Makhnatch, Pavel
    Khodabandeh, Rahmatollah
    Navarro-Esbri, Joaquin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 74 : 682 - 688
  • [30] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 139 - 147