Experimental evaluation of low-GWP refrigerants R513A, R1234yf and R436A as alternatives for R134a in a cascade refrigeration cycle with R744

被引:17
|
作者
Ojeda, Frank William Adolfo Blanco [1 ]
Queiroz, Marcus Vinicius Almeida [1 ]
Pico, David Fernando Marcucci [1 ]
Parise, Jose Alberto dos Reis [2 ]
Bandarra Filho, Enio Pedone [1 ]
机构
[1] Univ Fed Uberlandia, Sch Mech Engn, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, Brazil
[2] Pontif Catholic Univ Rio Janeiro, Dept Mech Engn, Rua Marques Sao Vicente,225 Gavea, BR-22453900 Rio De Janeiro, Brazil
关键词
Cascade; Refrigeration; Carbon dioxide; Low-GWP; TEWI; INTERNAL HEAT-EXCHANGER; PERFORMANCE EVALUATION; ENERGY PERFORMANCE; SYSTEM; R152A; R1234ZE(E); R290; CO2;
D O I
10.1016/j.ijrefrig.2022.08.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents an experimental analysis of the energy and environmental performance of low-GWP re-frigerants R513A, R1234yf and R436A as alternatives for R134a in a cascade refrigeration system that operates with R744 in low-temperature cycle. An apparatus was built using a well-insulated room, where tests were carried out in a steady state condition. In addition to the typical components of a cascade cycle, an intermediate heat exchanger was used to thermally communicate the low and high temperature cycles, thus providing additional superheating and subcooling, respectively. The cooling capacity of the system ranged from 2.2 to 3.8 kW, the evaporation temperature varied from-34 to-24.5 degrees C and the air temperature inside the cold room ranged from-23.1 to-9.4 degrees C. The results revealed that the alternative refrigerants are potential substitutes for R134a in cascade refrigeration systems, showing an average increase in the CRC coefficient of performance of 3.1% for R436A, while R1234yf and R513A exhibited a reduction of 3.7% and 4.4%, respectively. The environmental impact analysis considered the scenarios of Chicago (USA) and Curitiba (Brazil), the latter being a southern Brazilian city with a wet climate throughout the year, a warm and mostly cloudy summer, and a short and cold winter. Total TEWI values, compared to those obtained with the originally designed R134a system, showed reductions in CO2 equivalent emission of 46%, 42.1% and 22.5% for refrigerants R436A, R1234yf and R513A, respectively, for the Curitiba scenario, while the values for Chicago were increments of 0.3%, 2.4% and 5.8%, respectively.
引用
收藏
页码:175 / 187
页数:13
相关论文
共 50 条
  • [31] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    International Journal of Refrigeration, 2022, 135 : 139 - 147
  • [32] Assessment of a mini-channel condenser at high ambient temperatures based on experimental measurements working with R134a, R513A and R1234yf
    Lopez-Belchi, Alejandro
    APPLIED THERMAL ENGINEERING, 2019, 155 : 341 - 353
  • [33] R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 348 - 365
  • [34] Experimental analysis of the low-GWP refrigerant R1234yf as a drop-in replacement for R134a in a typical mobile air conditioning system
    Zhao, Yu
    Qi, Zhaogang
    Chen, Jiangping
    Xu, Baixing
    He, Bin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2012, 226 (C11) : 2713 - 2725
  • [35] Energy Analysis of R1234yf/R134a as Replacement of R134a in a Domestic Refrigerator
    Raveendran, P. Saji
    Murugan, P. C.
    Darwin, T.
    Glivin, Godwin
    Dwivedi, Gaurav
    ADVANCEMENT IN MATERIALS, MANUFACTURING AND ENERGY ENGINEERING, VOL. II, ICAMME 2021, 2022, : 495 - 502
  • [36] 混合制冷剂R134a/R1234yf(R513A)与R134a热力学性能对比及实验
    杨梦
    张华
    秦延斌
    孟照峰
    化工进展, 2019, 38 (03) : 1182 - 1189
  • [37] Experimental comparison of an air-to-water refrigeration system working with R134a and R1234yf
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 124 - 131
  • [38] R1234yf and R1234ze as alternatives to R134a in Organic Rankine Cycles for low temperature heat sources
    Moles, Francisco
    Navarro-Esbri, Joaquin
    Peris, Bernardo
    Mota-Babiloni, Adrian
    Mateu-Royo, Carlos
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1192 - 1198
  • [39] Performance analysis of refrigerants R134a and R1234yf two stage compression cycle with two condensers
    Wang, Hongli
    Tang, Qilong
    Jia, Ning
    Zhang, Qinghua
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2778 - +
  • [40] Experimental and Numerical Studies on an Automobile Air Conditioning System With the Refrigerants R134a, R1234yf, and R1234ze(E)
    Gurudatt, H. M.
    Narasimham, G. S. V. L.
    Sadashive Gowda, B.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)