Thermodynamic analysis of usage of R134a, R1234yf, R450A, R513A and R515B in the mechanical vapor compression refrigeration system

被引:0
|
作者
Bilen, Kemal [1 ]
Isik, Bilal [1 ]
Dagidir, Kayhan [2 ]
Arcaklioglu, Erol [1 ]
机构
[1] Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Dept Mech Engn, TR-06010 Ankara, Turkiye
[2] Tarsus Univ, Fac Engn, Dept Mech Engn, TR-33400 Mersin, Turkiye
关键词
R134a; Global warming potential; Alternative refrigerants; Refrigeration system; Thermodynamic analysis; LOWER GWP; REPLACEMENT; PERFORMANCE;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
R134a, which is used as a working fluid in Vapor Compression Refrigeration Systems (VCRS), is one of the refrigerants that is planned to be discontinued the usage due to the global warming. For this reason, researchers have tended to developing alternatives to R134a. In this context, in this study, the usage of R134a and its alternatives R1234yf, R450A, R513A, and R515B refrigerants were theoretically examined with the help of a theoretical model developed in the Engineering Equation Solver (EES) program using experimental data in terms of first and second laws of thermodynamics in a mechanical vapor compression refrigeration system. Analyses were performed for constant cooling capacity at various evaporation and condensation temperatures. In this study, the effects of the refrigerant type on the compressor power, heat rejection rate from the condenser, Coefficient of Performance (COP), second law efficiency, and mass flow rate of the refrigerant were determined. In addition, the results obtained under the same conditions for R134a and its alternatives were compared. As a result, compressor power increased by 5.62% for R1234yf, 2.35% for R450A, 3.41% for R513A, and 2.88% for R515B compared to R134a. Thus, it was observed that COP decreased by 5.32% for R1234yf, 2.30% for R450A, 3.30% for R513A, and 2.80% for R515B compared to R134a. Similarly, it was observed that the second law efficiency decreased by 5.32% in case of the usage of R1234yf, 2.30% in case of the usage of R450A, 3.29% in case of the usage of R513A, and 2.80% in case of the usage of R515B compared to R134a. Hence, it has been determined that the closest refrigerant to R134a in terms of the COP and the second law efficiency is R450A.
引用
收藏
页码:161 / 175
页数:15
相关论文
共 50 条
  • [1] Thermodynamic analysis of usage of R134a, R1234yf, R450A, R513A, and R515B in the mechanical vapor compression refrigeration system
    Bilen K.
    Işık B.
    Dağıdır K.
    Arcaklıoğlu E.
    Journal of the Faculty of Engineering and Architecture of Gazi University, 2023, 39 (01): : 161 - 175
  • [2] Thermodynamic performance comparison and experimental study of mixed refrigerant R134a/R1234yf (R513A) and R134a
    Yang, Meng
    Zhang, Hua
    Qin, Yanbin
    Meng, Zhaofeng
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (03): : 1182 - 1189
  • [3] EXPERIMENTAL STUDY ON R1234yf/R134a MIXTURE (R513a) AS R134a REPLACEMENT IN HEAT PIPES
    Kumar, Vivek
    Kabir, Raihanul
    Shannon, Zachary
    Waghmare, Prashant R.
    Flynn, M. R.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2025, 32 (04) : 1 - 23
  • [4] Experimental study on R1234yf/R134a mixture (R513A) as R134a replacement in a domestic refrigerator
    Yang, Meng
    Zhang, Hua
    Meng, Zhaofeng
    Qin, Yanbin
    APPLIED THERMAL ENGINEERING, 2019, 146 : 540 - 547
  • [5] Investigation of using R134a, R1234yf and R513A as refrigerant in a heat pump
    Yildiz, A.
    Yildirim, R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2021, 18 (05) : 1201 - 1210
  • [6] Investigation of using R134a, R1234yf and R513A as refrigerant in a heat pump
    A. Yıldız
    R. Yıldırım
    International Journal of Environmental Science and Technology, 2021, 18 : 1201 - 1210
  • [7] Theoretical analysis of R1234yf and R1234yf/R125 mixture as replacement of R134a in vapor compression system
    Lin, Yongmei
    Meng, Zhaofeng
    Huo, Ziheng
    Ding, Chuangchuang
    Wang, Song
    Wang, Longji
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 490 - 496
  • [8] PERFORMANCE OF R1234yf AND R513A AS ALTERNATIVES TO R134a IN AUTOMOTIVE AIR CONDITIONING SYSTEMS IN WINTER
    Meng, Zhaofeng
    Cui, Xiangna
    Liu, Yin
    Wang, Shun
    DU, Chenyang
    Hu, Rusheng
    THERMAL SCIENCE, 2023, 27 (3A): : 1937 - 1946
  • [9] Performance improvement strategies of R1234yf in vapor compression refrigeration system as a R134a replacement: A review
    Sharif, M. Z.
    Azmi, W. H.
    Ghazali, M. F.
    Samykano, M.
    Ali, Hafiz Muhammad
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [10] Exergy analysis of vapor compression refrigeration system using R450A as a replacement of R134a
    Gill, Jatinder
    Singh, Jagdev
    Ohunakin, Olayinka S.
    Adelekan, Damola S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (02) : 857 - 872