Thermodynamic analysis of usage of R134a, R1234yf, R450A, R513A and R515B in the mechanical vapor compression refrigeration system

被引:0
|
作者
Bilen, Kemal [1 ]
Isik, Bilal [1 ]
Dagidir, Kayhan [2 ]
Arcaklioglu, Erol [1 ]
机构
[1] Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Dept Mech Engn, TR-06010 Ankara, Turkiye
[2] Tarsus Univ, Fac Engn, Dept Mech Engn, TR-33400 Mersin, Turkiye
关键词
R134a; Global warming potential; Alternative refrigerants; Refrigeration system; Thermodynamic analysis; LOWER GWP; REPLACEMENT; PERFORMANCE;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
R134a, which is used as a working fluid in Vapor Compression Refrigeration Systems (VCRS), is one of the refrigerants that is planned to be discontinued the usage due to the global warming. For this reason, researchers have tended to developing alternatives to R134a. In this context, in this study, the usage of R134a and its alternatives R1234yf, R450A, R513A, and R515B refrigerants were theoretically examined with the help of a theoretical model developed in the Engineering Equation Solver (EES) program using experimental data in terms of first and second laws of thermodynamics in a mechanical vapor compression refrigeration system. Analyses were performed for constant cooling capacity at various evaporation and condensation temperatures. In this study, the effects of the refrigerant type on the compressor power, heat rejection rate from the condenser, Coefficient of Performance (COP), second law efficiency, and mass flow rate of the refrigerant were determined. In addition, the results obtained under the same conditions for R134a and its alternatives were compared. As a result, compressor power increased by 5.62% for R1234yf, 2.35% for R450A, 3.41% for R513A, and 2.88% for R515B compared to R134a. Thus, it was observed that COP decreased by 5.32% for R1234yf, 2.30% for R450A, 3.30% for R513A, and 2.80% for R515B compared to R134a. Similarly, it was observed that the second law efficiency decreased by 5.32% in case of the usage of R1234yf, 2.30% in case of the usage of R450A, 3.29% in case of the usage of R513A, and 2.80% in case of the usage of R515B compared to R134a. Hence, it has been determined that the closest refrigerant to R134a in terms of the COP and the second law efficiency is R450A.
引用
收藏
页码:161 / 175
页数:15
相关论文
共 50 条
  • [31] THERMODYNAMIC ANALYSES OF MULTIPLE EVAPORATORS VAPOR COMPRESSION REFRIGERATION SYSTEMS WITH R410A, R290, R1234YF, R502, R404A, R152A AND R134A
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (01)
  • [32] Experimental comparison of an air-to-water refrigeration system working with R134a and R1234yf
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 124 - 131
  • [33] Optimal design and environmental, energy and exergy analysis of a vapor compression refrigeration system using R290, R1234yf, and R744 as alternatives to replace R134a
    de Paula, Cleison Henrique
    Duarte, Willian Moreira
    Martins Rocha, Thiago Torres
    de Oliveira, Raphael Nunes
    Torres Maia, Antonio Augusto
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 (113) : 10 - 20
  • [34] Usage of R513A as an alternative to R134a in a refrigeration system: An experimental investigation based on the Kigali amendment
    Dağıdır K.
    Bilen K.
    International Journal of Thermofluids, 2024, 21
  • [35] Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan-Cervera, Angel
    Moles, Francisco
    Peris, Bernardo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 52 - 58
  • [36] Assessment of a mini-channel condenser at high ambient temperatures based on experimental measurements working with R134a, R513A and R1234yf
    Lopez-Belchi, Alejandro
    APPLIED THERMAL ENGINEERING, 2019, 155 : 341 - 353
  • [37] R450A and R513A as lower GWP mixtures for high ambient temperature countries: Experimental comparison with R134a
    Makhnatch, Pavel
    Mota-Babiloni, Adrian
    Lopez-Belchi, Alejandro
    Khodabandeh, Rahmatollah
    ENERGY, 2019, 166 : 223 - 235
  • [38] R515B和R513A直接替代R134a冷水机组性能试验研究
    沈中将
    王俊
    制冷与空调, 2023, 23 (07) : 91 - 97
  • [39] ENERGY AND EXERGY INVESTIGATIONS OF R1234yf AND R1234ze AS R134a REPLACEMENTS IN MECHANICALLY SUBCOOLED VAPOUR COMPRESSION REFRIGERATION CYCLE
    Agarwal, Shyam
    Arora, Akhilesh
    Arora, B. B.
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (01): : 109 - 132
  • [40] Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system
    Mota-Babiloni, Adrian
    Belman-Flores, J. M.
    Makhnatch, Pavel
    Navarro-Esbri, Joaquin
    Barroso-Maldonado, J. M.
    ENERGY, 2018, 162 : 99 - 110