Line spread function (LSF) study of a multimedia detector for x-ray digital imaging

被引:0
|
作者
Chowdhury, S [1 ]
Giakos, GC [1 ]
机构
[1] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An experimental study is in process aimed at enhancing the signal line spread function (LSF) of a novel imaging sensor which utilizes gas and semiconductor detector volumes. Preliminary results indicate the presence of general space charge nonlinearities which are partially reduced by adding small amount of methane. A significant improvement of the signal LSF is expected by adding traces of polar molecules with low ionization potential. The final goal of this study is to develop a high resolution imaging sensor for dual-energy medical imaging.
引用
收藏
页码:1431 / 1436
页数:6
相关论文
共 50 条
  • [31] Study of the X-ray energy utilization efficiency of the X-ray digital imaging systems in industrial applications
    Li Ruihong
    Han Yueping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 368 - 372
  • [32] Development of an X-ray imaging detector for high-energy X-ray microtomography
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 934 - 940
  • [33] Computer modeling of digital X-ray detector response
    Jensen, T
    Xu, J
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 507 - 514
  • [34] X-RAY BREMSSTRAHLUNG DETECTOR FOR DIGITAL KILOVOLT METERS
    AKATKIN, OA
    PELIPENKO, BF
    FEDOROV, VP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1992, 35 (04) : 613 - 614
  • [35] DESIGN PRACTICE OF AN AFFORDABLE DIGITAL X-RAY DETECTOR
    Alekseychuk, O.
    Fratzscher, D.
    Zscherpel, U.
    Ewert, U.
    10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 1173 - 1173
  • [36] Calibration and filtering of X-ray line array detector
    Geng L.
    Ma X.
    Xiao Z.
    Zhang F.
    Rong F.
    Peng X.
    Xiao, Zhitao (xiaozhitao@tjpu.edu.cn), 1600, Chinese Society of Astronautics (46):
  • [37] POINT SPREAD FUNCTION ESTIMATION IN X-RAY IMAGING WITH PARTIALLY COLLAPSED GIBBS SAMPLING
    Joyce, Kevin T.
    Bardsley, Johnathan M.
    Luttman, Aaron
    SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2018, 40 (03): : B766 - B787
  • [38] Monte Carlo investigation of backscatter point spread function for X-ray imaging examinations
    Xiong, Zhenyu
    Vijayan, Sarath
    Rudin, Stephen
    Bednarek, Daniel R.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [39] Application of charge-injection devices for digital X-ray imaging using a planar gas-type X-ray detector
    Oh, K.
    Shin, J.
    Yun, M.
    Park, H.
    Park, J.
    Nam, S.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [40] Soft X-ray microscope using an imaging detector
    Inoue, Soichi
    Ogawa, Yoji
    Ueda, Katsunobu
    Sumiya, Mitsuo
    Takigawa, Tadahiro
    Aoki, Sadao
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1990, 29 (01): : 176 - 178