An experimental study is in process aimed at enhancing the signal line spread function (LSF) of a novel imaging sensor which utilizes gas and semiconductor detector volumes. Preliminary results indicate the presence of general space charge nonlinearities which are partially reduced by adding small amount of methane. A significant improvement of the signal LSF is expected by adding traces of polar molecules with low ionization potential. The final goal of this study is to develop a high resolution imaging sensor for dual-energy medical imaging.
引用
收藏
页码:1431 / 1436
页数:6
相关论文
共 50 条
  • [21] 6 MVp x-ray imaging with a transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Rasmussen, J
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 388 - 394
  • [22] The development of x-ray imaging to study renal function
    Lerman, LO
    Rodriguez-Porcel, M
    Romero, JC
    KIDNEY INTERNATIONAL, 1999, 55 (02) : 400 - 416
  • [23] X-ray imaging with a silicon microstrip detector
    Mali, T
    Cindro, V
    Mikuz, M
    Zdesar, U
    DIGITAL MAMMOGRAPHY, 1998, 13 : 509 - 510
  • [24] Optimizing detector size in X-ray imaging
    Kachelriess, Marc
    Kalender, Willi A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2736 - 2740
  • [25] The pin pixel detector - X-ray imaging
    Bateman, JE
    Connolly, JF
    Derbyshire, GE
    Duxbury, DM
    Marsh, AS
    Simmons, JE
    Stephenson, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 482 (03): : 707 - 714
  • [26] Digital X-ray microscopy with a microfocal X-ray generation and an MWPC area detector
    Bateman, J.E.
    Moss, G.R.
    Rockett, P.
    Webb, S.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 767 - 772
  • [27] DIGITAL X-RAY MICROSCOPY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    MOSS, GR
    ROCKETT, P
    WEBB, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 767 - 772
  • [28] Characterization of an x-ray imaging setup for digital mammography based on a silicon microstrip detector
    Mali, T
    Cindro, V
    Mikuz, M
    Krizaj, D
    Vrtacnik, D
    Zdesar, U
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 89 - 94
  • [29] An X-ray imaging device based on a GEM detector with delay-line readout
    Zhou Yi
    Li Cheng
    Sun Yong-Jie
    Shao Ming
    CHINESE PHYSICS C, 2010, 34 (01) : 78 - 82
  • [30] An X-ray imaging device based on a GEM detector with delay-line readout
    周意
    李澄
    孙勇杰
    邵明
    中国物理C, 2010, (01) : 78 - 82