Analysis of the influence of implant shape on primary stability using the correlation of multiple methods

被引:33
|
作者
da Costa Valente, Mariana Lima [1 ]
de Castro, Denise Tornavoi [1 ]
Shimano, Antonio Carlos [2 ]
Lepri, Cesar Penazzo [3 ]
dos Reis, Andrea Candido [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, BR-14040904 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Dept Biomech Med & Rehabil Locomot Apparat, Sch Med Ribeirao Preto, BR-14040904 Ribeirao Preto, SP, Brazil
[3] Sch Dent Uberaba, Dept Biomat, Uberaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Osseointegration; Bone substitutes; Torque; Scanning electron microscopy; INSERTION TORQUE; DENTAL-IMPLANTS; BIOMECHANICAL EVALUATION; RESONANCE FREQUENCY; SURFACE; DESIGN;
D O I
10.1007/s00784-015-1417-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The purpose of this study was to analyze the influence of the shape of various implants and the density of substrate on primary stability using a combination of methods. Materials and methods Fifty-four NeodentA (R) brand cylindrical and conical implants with different prosthetic platforms were used. Implants were inserted into a pork rib bone and polyurethane blocks. Primary stability was assessed by insertion torque (IT), resonance frequency analysis (RFA), and pullout strength. Screws were also analyzed by scanning electron microscopy (SEM) before insertion and after removal to justify their use for inserting in different substrates. Results The conical cone morse implant had the highest average for all of the assays performed and was significantly different (p < 0.05) from the cylindrical implants for IT in the bone, pullout strength in the 40 per cubic foot (PCF) polyurethane, and the bone. The internal hex cylindrical implant had the lowest averages, which were significantly different (p < 0.05) from the conical implants for IT and RFA in the bone, pullout strength in the 40 PCF polyurethane, and the bone. The IT, RFA, and pullout strength assays were moderately correlated, and the photomicrographs did not reveal changes in the implants. Conclusions The analysis of different implants showed a better primary stability of tapered implants; the density of the substrate influences the primary stability and the 15 PCF polyurethane was not adequate to evaluate primary stability; correlation was obtained between the different methodologies of analysis of primary stability.
引用
收藏
页码:1861 / 1866
页数:6
相关论文
共 50 条
  • [31] A Comparative Assessment of Primary Implant Stability Using Osseodensification vs. Conventional Drilling Methods: A Systematic Review
    Althobaiti, Abdulrahman K.
    Ashour, Abdulrahman W.
    Halteet, Firas A.
    Alghamdi, Sulaiman I.
    Aboshetaih, Mohamed M.
    Al-Hayazi, Ali Mosa
    Saaduddin, Ahmed M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [32] Correlation of Implant Stability Between Two Noninvasive Methods Using Submerged and Nonsubmerged Healing Protocols: A Randomized Clinical Trial
    Aal, Marwa Abdel
    El Far, Mahmoud
    Sheta, Nora Mohamed
    Fayyad, Ahmed
    El Desouky, Eman
    Nabi, Nouran Mahmoud Abdel
    Ibrahim, Magdy
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (06) : 571 - 579
  • [33] Influence of different implant materials on the primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    Yang, Yi-Hsin
    Wu, Chao-Yi
    Lan, Ting-Hsun
    Liu, Pao-Hsin
    Chang, Hong-Po
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (12): : 673 - 678
  • [34] Influence of bone architecture on the primary stability of different mini-implant designs
    da Cunha, Amanda Carneiro
    Marquezan, Mariana
    Lima, Inaya
    Lopes, Ricardo Tadeu
    Nojima, Lincoln Issamu
    Sant'Anna, Eduardo Franzotti
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (01) : 45 - 51
  • [35] In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems
    Andres-Garcia, Rodrigo
    Garcia Vives, Nuria
    Herrero Climent, Federico
    Fernandez Palacin, Ana
    Rios Santos, Vicente
    Herrero Climent, Mariano
    Bullon, Pedro
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (02): : E93 - E97
  • [36] Correlation between peri-implant bone mineral density and primary implant stability based on artificial intelligence classification
    Xiao, Yanjun
    Lv, Lingfeng
    Xu, Zonghe
    Zhou, Lin
    Lin, Yanjun
    Lin, Yue
    Guo, Jianbin
    Chen, Jiang
    Ou, Yanjing
    Lin, Lin
    Wu, Dong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [37] Evaluation of postoperative dental implant primary stability using 3D finite element analysis
    Pammer, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 280 - 287
  • [38] ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD
    Vayron, Romain
    Mathieu, Vincent
    Michel, Adrien
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12): : 2885 - 2894
  • [39] Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets
    Cehreli, Murat Cavit
    Kokat, Ali Murat
    Comert, Ayhan
    Akkocaoglu, Murat
    Tekdemir, Ibrahim
    Akca, Kwanc
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1163 - 1169
  • [40] QUANTITATIVE MARKET ANALYSIS - MULTIPLE CORRELATION; ACCURACY OF THE METHODS
    Brown, Lyndon O.
    HARVARD BUSINESS REVIEW, 1937, 16 (01) : 62 - 73