Analysis of the influence of implant shape on primary stability using the correlation of multiple methods

被引:33
|
作者
da Costa Valente, Mariana Lima [1 ]
de Castro, Denise Tornavoi [1 ]
Shimano, Antonio Carlos [2 ]
Lepri, Cesar Penazzo [3 ]
dos Reis, Andrea Candido [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, BR-14040904 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Dept Biomech Med & Rehabil Locomot Apparat, Sch Med Ribeirao Preto, BR-14040904 Ribeirao Preto, SP, Brazil
[3] Sch Dent Uberaba, Dept Biomat, Uberaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Osseointegration; Bone substitutes; Torque; Scanning electron microscopy; INSERTION TORQUE; DENTAL-IMPLANTS; BIOMECHANICAL EVALUATION; RESONANCE FREQUENCY; SURFACE; DESIGN;
D O I
10.1007/s00784-015-1417-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The purpose of this study was to analyze the influence of the shape of various implants and the density of substrate on primary stability using a combination of methods. Materials and methods Fifty-four NeodentA (R) brand cylindrical and conical implants with different prosthetic platforms were used. Implants were inserted into a pork rib bone and polyurethane blocks. Primary stability was assessed by insertion torque (IT), resonance frequency analysis (RFA), and pullout strength. Screws were also analyzed by scanning electron microscopy (SEM) before insertion and after removal to justify their use for inserting in different substrates. Results The conical cone morse implant had the highest average for all of the assays performed and was significantly different (p < 0.05) from the cylindrical implants for IT in the bone, pullout strength in the 40 per cubic foot (PCF) polyurethane, and the bone. The internal hex cylindrical implant had the lowest averages, which were significantly different (p < 0.05) from the conical implants for IT and RFA in the bone, pullout strength in the 40 PCF polyurethane, and the bone. The IT, RFA, and pullout strength assays were moderately correlated, and the photomicrographs did not reveal changes in the implants. Conclusions The analysis of different implants showed a better primary stability of tapered implants; the density of the substrate influences the primary stability and the 15 PCF polyurethane was not adequate to evaluate primary stability; correlation was obtained between the different methodologies of analysis of primary stability.
引用
收藏
页码:1861 / 1866
页数:6
相关论文
共 50 条
  • [21] Reliability and Correlation of Different Devices for the Evaluation of Primary Implant Stability: An In Vitro Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Peleg, Maia
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2021, 14 (19)
  • [22] Influence of Implant Thread Morphology on Primary Stability: A Prospective Clinical Study
    Menini, Maria
    Bagnasco, Francesco
    Calimodio, Ivan
    Di Tullio, Nicolo
    Delucchi, Francesca
    Baldi, Domenico
    Pera, Francesco
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [23] Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    O'Sullivan, D
    Sennerby, L
    Meredith, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 474 - 480
  • [24] Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis
    Stoilov, Milan
    Shafaghi, Ramin
    Stark, Helmut
    Marder, Michael
    Kraus, Dominik
    Enkling, Norbert
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (09)
  • [25] Influence of Implant Geometry on Primary Insertion Stability and Simulated Pen-implant Bone Loss: An In Vitro Study Using Resonance Frequency Analysis and Damping Capacity Assessment
    Lachmann, Stefan
    Laval, Johannes Yves
    Axmann, Detlef
    Weber, Heiner
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 347 - 355
  • [26] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [27] Three-Dimensional Evaluation of Implant Bed Preparation and the Influence on Primary Implant Stability After Using 2 Different Surgical Techniques
    Moehlhenrich, Stephan Christian
    Heussen, Nicole
    Loberg, Christina
    Goloborodko, Evgeny
    Hoelzle, Frank
    Modabber, Ali
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (09) : 1723 - 1732
  • [28] GRAPHIC METHODS OF PRESENTING MULTIPLE CORRELATION ANALYSIS
    Card, Dana G.
    JOURNAL OF FARM ECONOMICS, 1943, 25 (04): : 881 - 889
  • [29] Analysis of tannins in red wine using multiple methods: Correlation with perceived astringency
    Kennedy, James A.
    Ferrier, Jordan
    Harbertson, James F.
    Peyrot des Gachons, Catherine
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 2006, 57 (04): : 481 - 485
  • [30] Meta-analysis of Methods Used to Assess Implant Stability
    Cehreli, Murat Cavit
    Karasoy, Durdu
    Akca, Kivanc
    Eckert, Steven E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1015 - 1032