Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis

被引:6
|
作者
Mendonca, Debora Sartori [1 ]
Fernandes Moron, Rafael Fontoura [1 ]
Louzada Maldonado, Andre Luiz [1 ,2 ]
Araujo Junior, Edward [1 ]
Machado Nardozza, Luciano Marcondes [1 ]
Moron, Antonio Fernandes [1 ]
机构
[1] Fed Univ Sao Paulo UNIFESP, Dept Obstet, Sao Paulo, Brazil
[2] Fed Univ Sao Paulo UNIFESP, Dept Diagnost Imaging, Sao Paulo, Brazil
来源
BMC VETERINARY RESEARCH | 2012年 / 8卷
关键词
Pregnant bitches; Renal volume; Two-dimensional ultrasound; Three-dimensional ultrasound; VOCAL; ULTRASOUND; KIDNEY; DOG;
D O I
10.1186/1746-6148-8-102
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: To assess and to compare the renal volume evolution in bitches during pregnancy by two-dimensional (2D) ultrasonography using the ellipsoid technique (volume = length x width x depth x 0.523) and three-dimensional (3D) ultrasonography using the Virtual Organ Computer-aided AnaLysis (VOCAL) method. A longitudinal prospective study was performed with 17 normal Golden Retrievers bitches during pregnancy from heat to the last third of gestation. The ultrasound scans were performed by two veterinarians. The left and right kidneys were assessed in three moments (day 0 = non-pregnant bitches; days 1st to 20th of pregnancy and days 21st to 40th of pregnancy) by three techniques (ellipsoid; VOCAL 12 degrees and VOCAL 30 degrees). For reproducibility calculations, we used the intraclass correlation coefficient (ICC). Results: The inferential result of the volumes in ANOVA revealed the interaction effect between side and moment (p = 0.009). The 3D techniques showed, in average, the same renal volumes (p = 0.137) regardless of the side and moment. Considering the right side, the renal volume in the day 0 was smaller than the day 21st to 40th (p = 0.029). Considering the left side, the renal volume at day 0 was smaller than the day 1st to 20th (p = 0.020) and day 21st to 40th (p = 0.007). It was found good intra observer reproducibility (ICC > 0.9) and none of the three techniques showed a good inter observer reproducibility (ICC < 0.7). Conclusion: The renal volume bitches by 3D ultrasonography using the VOCAL method (12 degrees and 30 degrees) had good correlation with the volume obtained by 2D ultrasonography method.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Use of virtual organ computer-aided analysis (VOCAL) for volume calculation compared to traditional volume calculations of fetal thoracic tumors
    Ehrig, Jessica
    Paulsen, Karen
    Tong, Suhong
    Meier, Maxene R.
    Lagueux, Megan
    Galan, Henry L.
    Zaretsky, Michael V.
    Behrendt, Nicholas
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (01) : S257 - S257
  • [42] Reference Range of Fetal Renal Volume by Three-Dimensional Ultrasonography Using the Vocal Method
    Tedesco, Giselle Darahem
    de Silva Bussamra, Luiz Claudio
    Araujo Junior, Edward
    Werneck Britto, Ingrid Schwach
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    Aoki, Tsutomu
    [J]. FETAL DIAGNOSIS AND THERAPY, 2009, 25 (04) : 385 - 391
  • [43] Volume-Doubling Time of Pulmonary Nodules with Ground Glass Opacity at Multidetector CT: Assessment with Computer-Aided Three-Dimensional Volumetry
    Oda, Seitaro
    Awai, Kazuo
    Murao, Kohei
    Ozawa, Akio
    Utsunomiya, Daisuke
    Yanaga, Yumi
    Kawanaka, Koichi
    Yamashita, Yasuyuki
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (01) : 63 - 69
  • [44] Computer-Aided Detection of Metastatic Brain Tumors Using Automated Three-Dimensional Template Matching
    Ambrosini, Robert D.
    Wang, Peng
    O'Dell, Walter G.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 85 - 93
  • [45] Measurement of guinea pig basilar membrane using computer-aided three-dimensional reconstruction system
    Wada, H
    Sugawara, M
    Kobayashi, T
    Hozawa, K
    Takasaka, T
    [J]. HEARING RESEARCH, 1998, 120 (1-2) : 1 - 6
  • [46] Three-dimensional carpal alignment: computer-aided CT analysis of carpal axes and normal ranges
    Hoglund, Theresa E. K.
    Sippo, Robert M. J.
    Waris, Eero
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (08) : 792 - 797
  • [47] Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography
    Athanasiou, Lambros
    Nezami, Farhad Rikhtegar
    Galon, Micheli Zanotti
    Lopes, Augusto Celso
    Lemos, Pedro Alves
    de la Torre Hernandez, Jose M.
    Ben-Assa, Eyal
    Edelman, Elazer R.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1168 - 1176
  • [48] Usefulness of three-dimensional fractal analysis for breast cancer detection in computer-aided diagnosis of mammograms
    Murase, K
    Tanki, N
    Kubota, H
    Yamazaki, Y
    Nagao, M
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1351 - 1351
  • [49] Narrowest (isthmus) portion of eustachian tube: A computer-aided three-dimensional reconstruction and measurement study
    Sudo, M
    Sando, I
    Ikui, A
    Suzuki, C
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1997, 106 (07): : 583 - 588
  • [50] Novel Arch Bar Fabricated With a Computer-Aided Design and Three-Dimensional Printing: A Feasibility Study
    He, Wei
    Sun, Yuchun
    Tian, Kaiyue
    Xie, Xiaoyan
    Wang, Xiaoxia
    Li, Zili
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (11) : 2162 - 2168