Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis

被引:6
|
作者
Mendonca, Debora Sartori [1 ]
Fernandes Moron, Rafael Fontoura [1 ]
Louzada Maldonado, Andre Luiz [1 ,2 ]
Araujo Junior, Edward [1 ]
Machado Nardozza, Luciano Marcondes [1 ]
Moron, Antonio Fernandes [1 ]
机构
[1] Fed Univ Sao Paulo UNIFESP, Dept Obstet, Sao Paulo, Brazil
[2] Fed Univ Sao Paulo UNIFESP, Dept Diagnost Imaging, Sao Paulo, Brazil
来源
BMC VETERINARY RESEARCH | 2012年 / 8卷
关键词
Pregnant bitches; Renal volume; Two-dimensional ultrasound; Three-dimensional ultrasound; VOCAL; ULTRASOUND; KIDNEY; DOG;
D O I
10.1186/1746-6148-8-102
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: To assess and to compare the renal volume evolution in bitches during pregnancy by two-dimensional (2D) ultrasonography using the ellipsoid technique (volume = length x width x depth x 0.523) and three-dimensional (3D) ultrasonography using the Virtual Organ Computer-aided AnaLysis (VOCAL) method. A longitudinal prospective study was performed with 17 normal Golden Retrievers bitches during pregnancy from heat to the last third of gestation. The ultrasound scans were performed by two veterinarians. The left and right kidneys were assessed in three moments (day 0 = non-pregnant bitches; days 1st to 20th of pregnancy and days 21st to 40th of pregnancy) by three techniques (ellipsoid; VOCAL 12 degrees and VOCAL 30 degrees). For reproducibility calculations, we used the intraclass correlation coefficient (ICC). Results: The inferential result of the volumes in ANOVA revealed the interaction effect between side and moment (p = 0.009). The 3D techniques showed, in average, the same renal volumes (p = 0.137) regardless of the side and moment. Considering the right side, the renal volume in the day 0 was smaller than the day 21st to 40th (p = 0.029). Considering the left side, the renal volume at day 0 was smaller than the day 1st to 20th (p = 0.020) and day 21st to 40th (p = 0.007). It was found good intra observer reproducibility (ICC > 0.9) and none of the three techniques showed a good inter observer reproducibility (ICC < 0.7). Conclusion: The renal volume bitches by 3D ultrasonography using the VOCAL method (12 degrees and 30 degrees) had good correlation with the volume obtained by 2D ultrasonography method.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Renal parenchymal volume increases after contralateral nephrectomy: Assessment using three-dimensional ultrasonography
    Funahashi, Yasuhito
    Hattori, Ryohei
    Yamamoto, Tokunori
    Aoki, Shigeyuki
    Majima, Tsuyoshi
    Gotoh, Momokazu
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2011, 18 (12) : 857 - 860
  • [22] Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis
    Munusamy, S. M.
    Yap, A. U.
    Ching, H. L.
    Yahya, N. A.
    [J]. OPERATIVE DENTISTRY, 2020, 45 (04) : E176 - E184
  • [23] Comparison of gestational sac volume by 3D-sonography using planimetric, virtual organ computer-aided analysis and extended imaging virtual organ computer-aided analysis methods between 7 and 11 weeks of pregnancy
    Machado Nardozza, Luciano Marcondes
    Rolo, Liliam Cristine
    Araujo Junior, Edward
    Nowak, Paulo Martin
    Bortoletti Filho, Joao
    Moron, Antonio Fernandes
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2010, 89 (03) : 328 - 334
  • [24] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    S. C. Chiou
    M. H. Hsieh
    H. Y. Chen
    J. D. Lin
    C. C. Chen
    W. H. Hsu
    L. B. Jeng
    C. T. Chang
    R. H. Chen
    T. Y. Wang
    W. L. Haung
    [J]. Journal of Endocrinological Investigation, 2009, 32 : 139 - 146
  • [25] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    Chiou, S. -C.
    Hsieh, M. -H.
    Chen, H. -Y.
    Lin, J. -D.
    Chen, C. -C.
    Hsu, W. -H.
    Jeng, L. -B.
    Chang, C. -T.
    Chen, R. -H.
    Wang, T. -Y.
    Haung, W. -L.
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2009, 32 (02) : 139 - 146
  • [26] Dental implant placement using computer-aided three-dimensional navigated procedures
    Nitsche, Tobias
    Menzebach, Marc
    Wiltfang, Joerg
    [J]. IMPLANTOLOGIE, 2011, 19 (03): : 243 - 250
  • [27] Three-Dimensional Computer-Aided Human Factors Engineering Analysis of a Grafting Robot
    Chiu, Y. C.
    Chen, S.
    Wu, G. J.
    Lin, Y. H.
    [J]. JOURNAL OF AGRICULTURAL SAFETY AND HEALTH, 2012, 18 (03): : 181 - 194
  • [28] A New Proposal for Three-Dimensional Positioning of the Chin Using a Single Computer-Aided Design/Computer-Aided Manufacturing Surgical Guide
    Cavalcante Costa, Pedro Jorge
    Demetrio, Mauricio Silva
    Bernardo Carvalho Nogueira, Pedro Thalles
    Rodrigues, Larissa Raposo
    Ribeiro Junior, Paulo Domingos
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) : 1963 - 1964
  • [29] Postnatal development of static volume of the eustachian tube lumen - A computer-aided three-dimensional reconstruction and measurement study
    Ishijima, K
    Sando, I
    Miura, M
    Balaban, CD
    Takasaki, K
    Sudo, M
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (09): : 832 - 835
  • [30] Computer-aided locoregional assessment of soft tissue sarcoma and three-dimensional simulator surgery
    DiSomma, C
    Cicchetti, E
    Casolino, D
    Canavese, G
    Toma, S
    Raposio, E
    Badellino, F
    [J]. MEDICINE MEETS VIRTUAL REALITY: HEALTH CARE IN THE INFORMATION AGE, 1996, 29 : 618 - 622