Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography

被引:17
|
作者
Athanasiou, Lambros [1 ,2 ]
Nezami, Farhad Rikhtegar [1 ]
Galon, Micheli Zanotti [3 ]
Lopes, Augusto Celso [4 ]
Lemos, Pedro Alves [3 ]
de la Torre Hernandez, Jose M. [1 ]
Ben-Assa, Eyal [1 ]
Edelman, Elazer R. [1 ,2 ]
机构
[1] MIT, Inst Med Engn & Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Harvard Med Sch, Brigham & Womens Hosp, Cardiovasc Div, Boston, MA 02115 USA
[3] Univ Sao Paulo, Heart Inst Incor, BR-05508020 Sao Paulo, Brazil
[4] Monte Klinikum Hosp, BR-60160140 Fortaleza, Ceara, Brazil
基金
美国国家卫生研究院;
关键词
Lumen detection; optical coherence tomography; 3D reconstruction; ENDOTHELIAL SHEAR-STRESS; INTRAVASCULAR ULTRASOUND; CORONARY-ARTERIES; ATHEROSCLEROTIC PLAQUE; QUANTITATIVE-ANALYSIS; METHODOLOGY; VIVO; ANGIOGRAPHY; ACQUISITION; PREDICTION;
D O I
10.1109/JBHI.2017.2762520
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We present a novel and time-efficient method for intracoronary lumen detection, which produces three-dimensional (3-D) coronary arteries using optical coherence tomographic (OCT) images. OCT images are acquired for multiple patients and longitudinal cross-section (LOCS) images are reconstructed using different acquisition angles. The lumen contours for each LOCS image are extracted and translated to 2-D cross-sectional images. Using two angiographic projections, the centerline of the coronary vessel is reconstructed in 3-D, and the detected 2-D contours are transformed to 3-D and placed perpendicular to the centerline. To validate the proposed method, 613 manual annotations from medical experts were used as gold standard. The 2-D detected contours were compared with the annotated contours, and the 3-D reconstructed models produced using the detected contours were compared to the models produced by the annotated contours. Wall shear stress (WSS), as dominant hemodynamics factor, was calculated using computational fluid dynamics and 844 consecutive 2-mm segments of the 3-D models were extracted and compared with each other. High Pearson's correlation coefficients were obtained for the lumen area ( r = 0.98) and local WSS (r = 0.97) measurements, while no significant bias with good limits of agreement was shown in the Bland-Altman analysis. The overlapping and nonoverlapping areas ratio between experts' annotations and presented method was 0.92 and 0.14, respectively. The proposed computer-aided lumen extraction and 3-D vessel reconstruction method is fast, accurate, and likely to assist in a number of research and clinical applications.
引用
收藏
页码:1168 / 1176
页数:9
相关论文
共 50 条
  • [1] Computer-aided three-dimensional reconstruction of main vessels in hemangiomas
    Wang, Guanghuan
    Zhong, Jun
    Li, Jianhong
    Zhang, Xuan
    Duan, Shouxing
    Fu, Maxian
    Wang, Fusheng
    Jiang, Xuewu
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (02): : 1747 - 1767
  • [2] Single cardiac cycle three-dimensional intracoronary optical coherence tomography
    Kim, Tae Shik
    Park, Hyun-Sang
    Jang, Sun-Joo
    Song, Joon Woo
    Cho, Han Saem
    Kim, Sunwon
    Bouma, Brett E.
    Kim, Jin Won
    Oh, Wang-Yuhl
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 4847 - 4858
  • [3] COMPUTER-AIDED THREE-DIMENSIONAL RECONSTRUCTION AND MEASUREMENT OF BONY AND MEMBRANOUS LABYRINTH
    戴朴
    姜泗长
    顾瑞
    方耀云
    [J]. 中华医学杂志(英文版), 1994, (09) : 77 - 80
  • [4] COMPUTER-AIDED THREE-DIMENSIONAL RECONSTRUCTION AND MEASUREMENT OF BONY AND MEMBRANOUS LABYRINTH
    戴朴
    姜泗长
    顾瑞
    方耀云
    [J]. ChineseMedicalJournal, 1994, (09)
  • [5] Computer-aided interactive three-dimensional reconstruction of the embryonic human heart
    Whiten, S
    Smart, SD
    McLachlan, JC
    Aiton, JF
    [J]. JOURNAL OF ANATOMY, 1998, 193 : 337 - 345
  • [6] Three-dimensional Reconstruction of Optical Coherence Tomography Images of Esophagus
    Nao, Sihan
    Zhang, Miao
    Wang, Lirong
    Xu, Yongjin
    Chen, Xiaohe
    [J]. PROCEEDINGS OF 2019 4TH INTERNATIONAL CONFERENCE ON BIOMEDICAL SIGNAL AND IMAGE PROCESSING (ICBIP 2019), 2019, : 77 - 82
  • [7] Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography
    Hori, Y
    Yasuno, Y
    Sakai, S
    Matsumoto, M
    Sugawara, T
    Madjarova, VD
    Yamanari, M
    Makita, S
    Araki, T
    Itoh, M
    Yatagai, T
    [J]. OPTICS EXPRESS, 2006, 14 (05) : 1862 - 1877
  • [8] Three-dimensional endomicroscopy using optical coherence tomography
    Adler, Desmond C.
    Chen, Yu
    Huber, Robert
    Schmitt, Joseph
    Connolly, James
    Fujimoto, James G.
    [J]. NATURE PHOTONICS, 2007, 1 (12) : 709 - 716
  • [9] Three-dimensional endomicroscopy using optical coherence tomography
    Desmond C. Adler
    Yu Chen
    Robert Huber
    Joseph Schmitt
    James Connolly
    James G. Fujimoto
    [J]. Nature Photonics, 2007, 1 : 709 - 716
  • [10] Computer-aided modeling of three-dimensional microcomponents
    Germer, C
    Hansen, U
    Franke, HJ
    [J]. INFORMATION PROCESSING IN PRODUCTION DEVELOPMENT: EFFICIENT 3D MODELING - ADVANCES AND PITFALLS, 2001, 1614 : 349 - 360