Determination of Clonidine by Potentiometry Using PVC Membrane Electrode

被引:0
|
作者
Ganjali, Mohammad Reza [1 ,2 ]
Karimi, Anahita [1 ]
Shahtaheri, Sayed Jamaleddin [3 ]
Norouzi, Parviz [1 ,2 ]
机构
[1] Univ Tehran, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Environm Res Ctr, Tehran, Iran
来源
关键词
Clonidine; Potentiometric Sensor; PVC membrane Electrode; Ion-Pair; COMPOSITE CARBON-PASTE; ION-SELECTIVE ELECTRODE; PHARMACEUTICAL FORMULATION; LANTHANIDE RECOGNITION; QUANTITATIVE-ANALYSIS; ANION RECOGNITION; SENSING MATERIAL; SENSOR; HYDROCHLORIDE; CONSTRUCTION;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
PVC membrane potentiometric sensor was made for determination of Clonidine in pharmaceutical formulations. The electrode respond based on ion-exchange mechanism. The ion-pair used as a sensing element in PVC membrane composition was synthesized by interaction of Clonidine hydrochloride and tetraphenyl borate. The best PVC membrane sensor response was obtained by a membrane composition of 30% PVC, 62% DBP, 6% ion-pair and 2% ionic liquid. The proposed method was successfully applied in determination of Clonidine in some formulations. The proposed sensor showed a linear dynamic range between 7.0x10(-6)-1.0x10(-2) M of Clonidine with a Nernstian slope of (58.3+/-0.4) mV decade(-1) and a detection limit of 6.5x10(-6) M. The proposed electrode displayed fast response time about 10 s, and lifetime of about six weeks without any significant change in its performance.
引用
收藏
页码:1999 / 2008
页数:10
相关论文
共 50 条
  • [21] An Ion-Selective Plasticized PVC Membrane Electrode for Tc(VII) Determination
    A. V. Dorokhov
    K. E. German
    V. F. Peretrukhin
    A. V. Kopytin
    E. N. Pyatova
    M. Yu. Burtsev
    M. Simonoff
    A. Yu. Tsivadze
    Doklady Physical Chemistry, 2003, 393 : 331 - 333
  • [22] A novel tetraiodocadmate(II) - PVC membrane electrode for the potentiometric determination of cadmium(II)
    Wang, Fu Chang
    Chai, Ya Qin
    Yuan, Ruo
    CHINESE CHEMICAL LETTERS, 2006, 17 (07) : 941 - 944
  • [23] Ion selective PVC membrane electrode for the determination of methacycline hydrochloride in pharmaceutical formulation
    Aboul-Enein, HY
    Sun, XX
    Sun, CJ
    SENSORS, 2002, 2 (10): : 424 - 431
  • [24] An ion-selective plasticized PVC membrane electrode for Tc(VII) determination
    Dorokhov, AV
    German, KE
    Peretrukhin, VF
    Kopytin, AV
    Pyatova, EN
    Burtsev, MY
    Simonoff, M
    Tsivadze, AY
    DOKLADY PHYSICAL CHEMISTRY, 2003, 393 (4-6) : 331 - 333
  • [25] PVC Membrane Electrode for Trinitrobenzenesulfonate and its Use for Indirect Determination of Amino Acids
    Issa, Yousry M.
    Badawy, Sayed S.
    Tag-Eldin, Ahmed S.
    Mikrochimica Acta, 1997, 126 (03): : 319 - 324
  • [26] PVC membrane electrode for trinitrobenzenesulfonate and its use for indirect determination of amino acids
    Issa, YM
    Badawy, SS
    TagEldin, AS
    MIKROCHIMICA ACTA, 1997, 126 (3-4) : 319 - 324
  • [27] The study on a PVC membrane electrode for gemfibrozil
    Xu, F
    Sun, LX
    Matsuda, N
    Okada, T
    Tan, ZC
    Liang, JG
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (02) : 165 - 167
  • [28] Determination of copper(II) in wastewater by electroplating samples using a PVC-membrane copper(II)-selective electrode
    H. A. Zamani
    G. Rajabzadeh
    A. Firouz
    M. R. Ganjali
    Journal of Analytical Chemistry, 2007, 62 : 1080 - 1087
  • [29] Determination of copper(II) in wastewater by electroplating samples using a PVC-membrane copper(II)-selective electrode
    Zamani, H. A.
    Rajabzadeh, G.
    Firouz, A.
    Ganjali, M. R.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (11) : 1080 - 1087
  • [30] Determination of forchlorfenuron by zero current potentiometry using poly-β-cyclodextrin modified electrode
    Mingming, M.A.
    Chengyi, H.E.
    Shuai, S.H.I.
    Shuhui, C.U.I.
    Jia, L.I.U.
    Chinese Journal of Analysis Laboratory, 2024, 43 (01) : 64 - 69