Determination of Clonidine by Potentiometry Using PVC Membrane Electrode

被引:0
|
作者
Ganjali, Mohammad Reza [1 ,2 ]
Karimi, Anahita [1 ]
Shahtaheri, Sayed Jamaleddin [3 ]
Norouzi, Parviz [1 ,2 ]
机构
[1] Univ Tehran, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Environm Res Ctr, Tehran, Iran
来源
关键词
Clonidine; Potentiometric Sensor; PVC membrane Electrode; Ion-Pair; COMPOSITE CARBON-PASTE; ION-SELECTIVE ELECTRODE; PHARMACEUTICAL FORMULATION; LANTHANIDE RECOGNITION; QUANTITATIVE-ANALYSIS; ANION RECOGNITION; SENSING MATERIAL; SENSOR; HYDROCHLORIDE; CONSTRUCTION;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
PVC membrane potentiometric sensor was made for determination of Clonidine in pharmaceutical formulations. The electrode respond based on ion-exchange mechanism. The ion-pair used as a sensing element in PVC membrane composition was synthesized by interaction of Clonidine hydrochloride and tetraphenyl borate. The best PVC membrane sensor response was obtained by a membrane composition of 30% PVC, 62% DBP, 6% ion-pair and 2% ionic liquid. The proposed method was successfully applied in determination of Clonidine in some formulations. The proposed sensor showed a linear dynamic range between 7.0x10(-6)-1.0x10(-2) M of Clonidine with a Nernstian slope of (58.3+/-0.4) mV decade(-1) and a detection limit of 6.5x10(-6) M. The proposed electrode displayed fast response time about 10 s, and lifetime of about six weeks without any significant change in its performance.
引用
收藏
页码:1999 / 2008
页数:10
相关论文
共 50 条
  • [41] Determination of total fluoride in oral products by using of potentiometry with ion selective electrode:: A critical study
    Cassella, RJ
    Araújo, HD
    da Silva, AI
    Cruz, MB
    Campos, MD
    ANALYTICAL LETTERS, 2000, 33 (05) : 819 - 829
  • [42] ELECTRODE MEMBRANE AND SOLVENT-EXTRACTION PARAMETERS RELATING TO THE POTENTIOMETRY OF POLYALKOXYLATES
    ALEXANDER, PHV
    MOODY, GJ
    THOMAS, JDR
    ANALYST, 1987, 112 (02) : 113 - 120
  • [43] LIQUID MEMBRANE-ELECTRODE FOR DIRECT POTENTIOMETRY AND POTENTIOMETRIC TITRATION OF STRYCHNINE
    HASSAN, SSM
    ELSAYES, MB
    ANALYTICAL CHEMISTRY, 1979, 51 (11) : 1651 - 1654
  • [44] Determination of Erbium Ions in Water Samples by a PVC Membrane Erbium-Ion Selective Electrode
    Zamani, Hassan Ali
    Mohammadhosseini, Majid
    Nekoei, Mehdi
    Ganjali, Mohammad Reza
    SENSOR LETTERS, 2010, 8 (02) : 303 - 307
  • [45] Molecularly Imprinted Polymer Based PVC-Membrane-Coated Graphite Electrode for the Determination of Metoprolol
    Tehrani, Mohammad Saber
    Vardini, Mohammad Taghi
    Azar, Parviz Abroomand
    Husain, Syed Waqif
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 88 - 104
  • [46] Molecularly Imprinted Polymer Based PVC-Membrane-Coated Graphite Electrode for the Determination of Metoprolol
    Tehrani, M. Saber
    Vardini, M. T.
    Azar, P. Abroomand
    Husain, S. W.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2010, 7 (03) : 759 - 769
  • [47] PVC Membrane Electrode Modified by Lawson as Synthetic Derivative Ionophore for Determination of Cadmium in Alloy and Wastewater
    Peyman, Hossein
    Roshanfekr, Hamideh
    Babakhanian, Arash
    Jafari, Hadi
    CHEMICAL METHODOLOGIES, 2021, 5 (05): : 446 - 453
  • [48] DETERMINATION OF PYRIDINEMONOCARBOXYLIC ACIDS USING A LIQUID MEMBRANE ELECTRODE
    CAMPANELLA, L
    GOZZI, D
    ANNALI DI CHIMICA, 1977, 67 (5-6) : 345 - 351
  • [49] PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine
    Amini, MK
    Shahrokhian, S
    Tangestaninejad, S
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2502 - 2505
  • [50] PVC Membrane Selective Electrode for Determination of Isoproterenol based on Naphthylethylenediamine Dihydrochloride-Tetraphenyl Boranuide
    Ensafi, Ali A.
    Allafchian, Alireza
    Rezaei, Behzad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 569 - 581