Petal resonator surface coil with a circular envelope for high field magnetic resonance imaging

被引:0
|
作者
Hidalgo, S. S. [1 ]
Cuellar, G. [1 ]
Solis, S. E. [1 ]
Alejski, A.
Rodriguez, A. O. [1 ]
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Ctr Invest & Instrumentac & Imagenol Med, Mexico City 09340, DF, Mexico
来源
MEDICAL PHYSICS | 2008年 / 1032卷
关键词
PERES coil; magnetic resonance imaging; electromagnetic simulation; high field;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
A modified version of the petal resonator surface (PERES) coil is proposed in which the petal coils are located inside a circular-shaped coil as opposed to the previous PERES version which did not have a circular envelope. An 8-petal coil was simulated using a finite element method and the quasi-static approach to numerically investigate its electromagnetic characteristics. Numerical simulations showed that the field uniformity is not greatly affected by the use of circular-shaped coil inside in the circular envelope. A coil prototype was developed using the same coil configuration as above and tested on a commercial 3 T imager and a General Electric phantom. Phantom images also demonstrated that the mutual inductance between petals does not alter the coil performance. Standard pulse sequences were used to acquire phantom images with the petal resonator surface coil. It was shown that this prototype resonator coil is fully compatible with clinical high field MR imagers and clinical pulse sequences.
引用
收藏
页码:225 / 228
页数:4
相关论文
共 50 条
  • [31] Surface Head Coil for 10.5 Tesla Magnetic Resonance Imaging (MRI)
    Motovilova, Elizaveta
    Huang, Shao Ying
    Su, Jiasheng
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON ADVANCED MATERIALS AND PROCESSES FOR RF AND THZ APPLICATIONS (IMWS-AMP), 2015, : 86 - 88
  • [32] CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING
    BREY, WW
    NARAYANA, PA
    MEDICAL PHYSICS, 1988, 15 (02) : 241 - 245
  • [33] MAGNETIC-RESONANCE IMAGING OF THE ORBITS USING A BINOCULAR SURFACE COIL
    DEANS, HE
    REDPATH, TW
    SMITH, FW
    PAREKH, S
    FORRESTER, JV
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 665 - 672
  • [34] Magnetic resonance imaging of cervical carcinoma using an endorectal surface coil
    Brocker, Kerstin A.
    Alt, Celine D.
    Gebauer, Gerhard
    Sohn, Christof
    Hallscheidt, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1030 - 1035
  • [35] Surface coil intensity correction in magnetic resonance imaging in spinal metastases
    Ren, Hong
    Lin, Wei
    Ding, Xianjun
    OPEN MEDICINE, 2017, 12 (01): : 138 - 143
  • [36] COMPENSATION FOR SURFACE COIL SENSITIVITY VARIATION IN MAGNETIC-RESONANCE IMAGING
    NARAYANA, PA
    BREY, WW
    KULKARNI, MV
    SIEVENPIPER, CL
    MAGNETIC RESONANCE IMAGING, 1988, 6 (03) : 271 - 274
  • [37] High-Field Magnetic Resonance Imaging
    Kangarlu, Alayar
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (01) : 113 - +
  • [38] A Comparative Study of Birdcage RF Coil Configurations for Ultra-High Field Magnetic Resonance Imaging
    Seo, Jeung-Hoon
    Han, Yeji
    Chung, Jun-Young
    SENSORS, 2022, 22 (05)
  • [39] Dual-Band Transceiver High Impedance Coil Array for Ultrahigh Field Magnetic Resonance Imaging
    Mollaei, Masoud Sharifian Mazraeh
    Mollaei, Ali Sharifian Mazraeh
    Simovski, Constantin R.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2022, 70 (02) : 1033 - 1044
  • [40] A dual RF resonator system for high-field functional magnetic resonance imaging of small animals
    Ludwig, R
    Bodgdanov, G
    King, J
    Allard, A
    Ferris, CF
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 132 (02) : 125 - 135