Petal resonator surface coil with a circular envelope for high field magnetic resonance imaging

被引:0
|
作者
Hidalgo, S. S. [1 ]
Cuellar, G. [1 ]
Solis, S. E. [1 ]
Alejski, A.
Rodriguez, A. O. [1 ]
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Ctr Invest & Instrumentac & Imagenol Med, Mexico City 09340, DF, Mexico
来源
MEDICAL PHYSICS | 2008年 / 1032卷
关键词
PERES coil; magnetic resonance imaging; electromagnetic simulation; high field;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
A modified version of the petal resonator surface (PERES) coil is proposed in which the petal coils are located inside a circular-shaped coil as opposed to the previous PERES version which did not have a circular envelope. An 8-petal coil was simulated using a finite element method and the quasi-static approach to numerically investigate its electromagnetic characteristics. Numerical simulations showed that the field uniformity is not greatly affected by the use of circular-shaped coil inside in the circular envelope. A coil prototype was developed using the same coil configuration as above and tested on a commercial 3 T imager and a General Electric phantom. Phantom images also demonstrated that the mutual inductance between petals does not alter the coil performance. Standard pulse sequences were used to acquire phantom images with the petal resonator surface coil. It was shown that this prototype resonator coil is fully compatible with clinical high field MR imagers and clinical pulse sequences.
引用
收藏
页码:225 / 228
页数:4
相关论文
共 50 条
  • [21] Primary adenosquamous cell carcinoma of the male distal urethra: Magnetic resonance imaging using a circular surface coil
    Kageyama, S
    Ueda, T
    Kushima, R
    Sakamoto, T
    JOURNAL OF UROLOGY, 1997, 158 (05): : 1913 - 1914
  • [22] The magnetic field of a circular cylindrical coil
    Dwight, HB
    PHILOSOPHICAL MAGAZINE, 1931, 11 (72): : 948 - 957
  • [23] Staging of cervical carcinomas - Comparison of body-coil magnetic resonance imaging and endorectal surface coil magnetic resonance imaging with histopathologic correlation
    Preidler, KW
    Tamussino, K
    Szolar, DM
    Ranner, G
    Ebner, F
    INVESTIGATIVE RADIOLOGY, 1996, 31 (07) : 458 - 462
  • [24] Novel Multi-channel Transmission Line Coil for High Field Magnetic Resonance Imaging
    Akgun, Can Eyup
    DelaBarre, Lance
    Sohn, Sung-Min
    Snyder, Carl
    Adriany, Gregor
    Ugurbil, Kamil
    Vaughan, John Thomas
    Gopinath, Anand
    2009 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, VOLS 1-3, 2009, : 1425 - +
  • [25] High-resolution magnetic resonance imaging of esophageal cancer using an endoluminal surface coil
    Ozawa, S
    Imai, Y
    Ando, N
    Shinozaki, H
    Kitajima, M
    RECENT ADVANCES IN DISEASES OF THE ESOPHAGUS: SELECTED PAPERS IN 6TH WORLD CONGRESS OF THE INTERNATIONAL SOCIETY FOR DISEASES OF THE ESOPHAGUS, 1996, : 165 - 175
  • [26] ANALYSIS OF A FLEXIBLE SURFACE-COIL-TYPE RESONATOR FOR MAGNETIC-RESONANCE MEASUREMENTS
    HIRATA, H
    IWAI, H
    ONO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (09): : 4529 - 4534
  • [27] Design and implementation of uniplanar gradient field coil for magnetic resonance imaging
    Lemdiasov, RA
    Ludwig, R
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 1939 - 1943
  • [28] Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging
    Lemdiasov, R
    Ludwig, R
    Brevard, M
    Ferris, C
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 20B (01) : 17 - 29
  • [29] Imaging of the dielectric resonance effect in high field magnetic resonance imaging
    Mihara, H., 1600, American Institute of Physics Inc. (97):
  • [30] Imaging of the dielectric resonance effect in high field magnetic resonance imaging
    Mihara, H
    Iriguchi, N
    Ueno, S
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (10)