Shimoda, Tomofumi [1 ]
Kokuyama, Wataru [1 ]
Nozato, Hideaki [1 ]
机构
[1] Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
关键词
seismometer; calibration; traceability; low-frequency vibration; tilt coupling;
D O I
10.1088/1361-6501/ac9077
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Broadband seismometers have been widely employed in geophysical observation and disaster prevention. To ensure the reliability of the measurement, traceable calibration of their sensitivities following ISO 16063-11 down to 8 mHz is required. However, the calibration accuracy generally degrades below 0.1 Hz due to tilt-coupling error. In this paper, two tilt-coupling correction methods are investigated: one is a dynamic tilt measurement method using an autocollimator, and the other is a comparison method using a reference accelerometer. These methods were introduced to the primary calibration system to calibrate a seismometer between 5 mHz and 200 Hz. As a result, the tilt-coupling error was corrected with an estimated uncertainty of less than 2% at 5 mHz, and the bandpass response of the seismometer sensitivity was confirmed with the traceable method.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Traceable calibration of ultraviolet meters used with broadband, extended sources
    Coleman, AJ
    Collins, M
    Saunders, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 185 - 196
  • [2] On the calibration of feedback broadband seismometer FBS-3A with current signal
    刘庆伟
    庄灿涛
    Acta Seismologica Sinica, 2001, (02) : 203 - 215
  • [3] On the calibration of feedback broadband seismometer FBS-3A with current signal
    Liu, Qing-Wei
    Acta Seismologica Sinica English Edition, 2001, 14 (02): : 203 - 215
  • [4] Wideband Current Transducer Traceable Calibration up to 10 A and 1 MHz
    Ouameur, Mohamed
    Istrate, Daniela
    Ziade, Francois
    SENSORS, 2024, 24 (08)
  • [5] An experimental setup for traceable measurement and calibration of liquid flow rates down to 5 nl/min
    Ahrens, Martin
    Nestler, Bodo
    Klein, Stephan
    Lucas, Peter
    Petter, Harm Tido
    Damiani, Christian
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2015, 60 (04): : 337 - 345
  • [6] Setup of a Broadband High-Current Measuring System for the Traceable Calibration of Current Transducers
    Ohlrogge, Matthias
    Hoenninger, Roman
    Kult, Michael
    Jurgeit, Stefan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [7] Setup of a Broadband High-Current Measuring System for the Traceable Calibration of Current Transducers
    Ohlrogge, Matthias
    Hoenninger, Roman
    Kult, Michael
    Jurgeit, Stefan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [8] Design and simulation of a vertical broadband seismometer
    E. Habbak
    H. Nofal
    E. Lotfy
    S. El-Sabban
    Z. Nossair
    Arabian Journal of Geosciences, 2016, 9
  • [9] Design and simulation of a vertical broadband seismometer
    Habbak, E.
    Nofal, H.
    Lotfy, E.
    El-Sabban, S.
    Nossair, Z.
    ARABIAN JOURNAL OF GEOSCIENCES, 2016, 9 (05)
  • [10] A SIMPLE SHAKER TABLE FOR SEISMOMETER CALIBRATION
    DUENNEBIER, FK
    SUTTON, GH
    HARRIS, D
    BYRNE, DA
    MARINE GEOPHYSICAL RESEARCHES, 1984, 6 (03) : 311 - 328