Wear at the taper-trunnion junction of contemporary ceramic-on-ceramic hips shown in a multistation hip simulator

被引:13
|
作者
Bhalekar, Rohan M. [1 ]
Smith, Simon L. [1 ]
Joyce, Thomas J. [1 ]
机构
[1] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
total hip replacement; ceramic-on-ceramic; hip simulator; taper-trunnion junction; wear; TITANIUM-ALLOY; IN-VITRO; METAL; FAILURE; HEAD; PROSTHESES; UHMWPE; DEBRIS; MICROSEPARATION; BEARINGS;
D O I
10.1002/jbm.b.34213
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ceramic-on-ceramic (CoC) total hip replacements (THR) have a substantially lower wear rate than metal-on-polyethylene (MoP) hips, as shown by hip simulator testing. However, the revision rates of CoC and MoP hips are comparable. To try and explain this discrepancy the wear, at both the bearing surfaces and taper-trunnion interface of 36 mm BIOLOXdelta CoC THRs, mounted on 12/14 titanium (Ti6Al4V) trunnions was investigated using a hip simulator (n = 3) and a dynamically loaded CoC sample in a separate test station. Wear was assessed gravimetrically and surface roughness measurements of the articulating and taper surfaces taken at regular intervals. Scanning electron microscopy, surface roughness, and gravimetric measurements of trunnions was performed. After 5 million cycles, the mean total wear from the ceramic articulating surfaces was 0.25 mm(3) from the hip simulator test, and that from the titanium trunnions was 0.29 mm(3). This metal wear may provide an explanation for adverse reaction to metal debris found in contemporary CoC hip joints. It is therefore vital to consider taper-trunnion wear in preclinical testing of artificial hip joints. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1199-1209, 2019.
引用
收藏
页码:1199 / 1209
页数:11
相关论文
共 50 条
  • [41] Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design and orientation as influence parameters
    Bader, R
    Steinhauser, E
    Gradinger, R
    Willmann, G
    Mittelmeier, W
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2002, 140 (03): : 310 - 316
  • [42] Hip-simulator ranking of polyethylene wear - Comparisons between ceramic heads of different sizes
    Clarke, IC
    Gustafson, A
    Jung, H
    Fujisawa, A
    ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02): : 128 - 132
  • [43] Ceramic-on-ceramic vs. metal-on-metal in total hip arthroplasty (THA): do 36-mm diameters exhibit comparable wear performance?
    Spinelli, M.
    Affatat, S.
    Corvil, A.
    Viceconti, M.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2009, 40 (1-2) : 94 - 97
  • [44] Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system
    Brock, Timothy M.
    Sidaginamale, Raghavendra
    Rushton, Steven
    Nargol, Antoni V. F.
    Bowsher, John G.
    Savisaar, Christina
    Joyce, Tom J.
    Deehan, David J.
    Lord, James K.
    Langton, David J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (12) : 1868 - 1874
  • [45] Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up
    Niu, Erlong
    Fu, Jun
    Li, Hao
    Ni, Ming
    Hao, Libo
    Zhou, Yonggang
    Xu, Chi
    Chen, Jiying
    JOURNAL OF ARTHROPLASTY, 2023, 38 (08): : 1539 - 1544
  • [46] Influence of Metallic Deposition on Ceramic Femoral Heads on the Wear Behavior of Artificial Hip Joints: A Simulator Study
    Hembus, Jessica
    Roessler, Lisa
    Jackszis, Mario
    Klinder, Annett
    Bader, Rainer
    Zietz, Carmen
    MATERIALS, 2020, 13 (16)
  • [47] The influence of acetabular cup angle on the wear of “BIOLOX Forte” alumina ceramic bearing couples in a hip joint simulator
    J. E. Nevelos
    E. Ingham
    C. Doyle
    A. B. Nevelos
    J. Fisher
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 141 - 144
  • [48] The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
    Nevelos, JE
    Ingham, E
    Doyle, C
    Nevelos, AB
    Fisher, J
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (02) : 141 - 144
  • [49] Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation
    Ashkanfar, Ariyan
    Langton, David J.
    Joyce, Thomas J.
    JOURNAL OF BIOMECHANICS, 2017, 63 : 47 - 54
  • [50] Comparison of standard model and HIP-simulator examinations on wear and tear protection coats for metal-ceramic matchings in hip joint endoprosthesis
    Hartelt, M.
    Wäsche, R.
    Djahanbaksh, M.
    Österle, W.
    Tribologie und Schmierungstechnik, 2008, 55 (01): : 21 - 25