摘要
Ceramic-on-ceramic (CoC) total hip replacements (THR) have a substantially lower wear rate than metal-on-polyethylene (MoP) hips, as shown by hip simulator testing. However, the revision rates of CoC and MoP hips are comparable. To try and explain this discrepancy the wear, at both the bearing surfaces and taper-trunnion interface of 36 mm BIOLOXdelta CoC THRs, mounted on 12/14 titanium (Ti6Al4V) trunnions was investigated using a hip simulator (n = 3) and a dynamically loaded CoC sample in a separate test station. Wear was assessed gravimetrically and surface roughness measurements of the articulating and taper surfaces taken at regular intervals. Scanning electron microscopy, surface roughness, and gravimetric measurements of trunnions was performed. After 5 million cycles, the mean total wear from the ceramic articulating surfaces was 0.25 mm(3) from the hip simulator test, and that from the titanium trunnions was 0.29 mm(3). This metal wear may provide an explanation for adverse reaction to metal debris found in contemporary CoC hip joints. It is therefore vital to consider taper-trunnion wear in preclinical testing of artificial hip joints. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1199-1209, 2019.
引用
收藏
页码:1199 / 1209
页数:11
相关论文
共 50 条
  • [31] Uncemented third-generation ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner
    Tsukada, Sachiyuki
    Wakui, Motohiro
    Matsueda, Munenori
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 861 - 868
  • [32] Ceramic-on-ceramic bearing surfaces:: A complete solution to 3rd-body wear problem in total hip arthroplasty
    Wang, A
    Chopra, A
    Schmidig, G
    BIOCERAMICS 14, 2002, 218-2 : 669 - 672
  • [33] Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions
    Al-Hajjar, Mazen
    Fisher, John
    Tipper, Joanne L.
    Williams, Sophie
    Jennings, Louise M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 535 - 542
  • [34] Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants - A 12-year follow-up study
    Jazrawi, LM
    Bogner, E
    Della Valle, CJ
    Chen, FS
    Pak, KI
    Stuchin, SA
    Frankel, VH
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 1999, 14 (07): : 781 - 787
  • [35] Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement
    Al-Hajjar, Mazen
    Leslie, Ian J.
    Tipper, Joanne
    Williams, Sophie
    Fisher, John
    Jennings, Louise M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (02) : 263 - 268
  • [36] Minimum 10-Year Results of Cementless Ceramic-On-Ceramic Total Hip Arthroplasty Performed With Transverse Subtrochanteric Osteotomy in Crowe Type IV Hips
    Caylak, Remzi
    Ors, Cagri
    Togrul, Emre
    JOURNAL OF ARTHROPLASTY, 2021, 36 (10): : 3519 - 3526
  • [37] WEAR OF THE POLYETHYLENE ACETABULAR CUP - METALLIC AND CERAMIC HEADS COMPARED IN A HIP SIMULATOR
    SAIKKO, VO
    PAAVOLAINEN, PO
    SLATIS, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (04): : 391 - 402
  • [38] Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surface
    Yamamoto, T
    Saito, M
    Ueno, M
    Hananouchi, T
    Tokugawa, Y
    Yonenobu, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 73B (02) : 301 - 307
  • [39] Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    Clarke, IC
    Gustafson, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) : 34 - 40
  • [40] Investigation of the wear properties of ceramic total hip prostheses made of alumina and zirconia combination: A hip simulator study
    Ueno, M
    Ikeuchi, K
    BIOCERAMICS 15, 2003, 240-2 : 809 - 812