Implant-related infections are disastrous complications in the clinic, and there are no effective therapies. In this preliminary study, gentamicin-loaded coating on titanium implants was prepared using the electrospinning technique, and some properties of the coating titanium implants were studied. We adopted the electrospinning technique to prepare gentamicin-coated titanium implants. The surface structure of the coating implants was observed using scanning electron microscope. An elution study was performed to determine the release behavior of the gentamicin from the coating. The antibacterial efficacy and quantitative analysis of the bacterial adhesion of were evaluated in vitro, and the cytotoxicity of the coated titanium implants on osteoblasts was investigated in vitro. The morphology of the gentamicin-coated titanium implants exhibited nanofibers, and the release of gentamicin showed an initial gentamicin burst followed by a slow release. The gentamicin-coated titanium implants had a persistent antibacterial efficacy for 1 week and significantly reduced the adhesion of the compared with bare titanium implants in vitro. There was no cytotoxicity observed in vitro for the gentamicin-coated implants. The gentamicin-coated titanium implants, which were prepared using an electrospinning technique, present many advantages and may be considered to prevent and treat the implant-related infections.
引用
收藏
页码:897 / 903
页数:7
相关论文
共 50 条
  • [1] Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro
    Liang-liang Li
    Li-ming Wang
    Yan Xu
    Lan-xin Lv
    [J]. Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 897 - 903
  • [2] Novel bilayer coating on gentamicin-loaded titanium nanotube for orthopedic implants applications
    Shaygani, Hossein
    Seifi, Saeed
    Shamloo, Amir
    Golizadeh, Mortaza
    Rahnamaee, Seyed Yahya
    Alishiri, Mojgan
    Ebrahimi, Sina
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 636
  • [3] Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium
    Stevanovic, Milena
    Dosic, Marija
    Jankovic, Ana
    Kojic, Vesna
    Vukasinovic-Sekulic, Maja
    Stojanovic, Jovica
    Odovic, Jadranka
    Sakasc, Milkica Crevar
    Rhee, Kyong Yop
    Miskovic-Stankovic, Vesna
    [J]. ACS BIOMATERIALS SCIENCE & ENGINEERING, 2018, 4 (12): : 3994 - 4007
  • [4] Electrophoretic Deposition of Gentamicin-Loaded ZnHNTs-Chitosan on Titanium
    Humayun, Ahmed
    Luo, Yangyang
    Mills, David K.
    [J]. COATINGS, 2020, 10 (10) : 1 - 18
  • [5] BIODEGRADABLE GENTAMICIN-LOADED CONTROLLED RELEASE IMPLANTS MADE OF BETA-TRICALCIUM PHOSPHATE CERAMICS .2. PREPARATION AND INVITRO EVALUATION OF GENTAMICIN-LOADED CONTROLLED RELEASE PELLETS
    THOMA, K
    ALEX, R
    [J]. PHARMAZIE, 1991, 46 (03): : 198 - 202
  • [6] Physical Properties and Antimicrobial Release Ability of Gentamicin-Loaded Apatite Cement/α-TCP Composites: An In Vitro Study
    Sasaki, Kazuki
    Ninomiya, Yoshiaki
    Takechi, Masaaki
    Tsuru, Kanji
    Ishikawa, Kunio
    Shigeishi, Hideo
    Ohta, Kouji
    Aikawa, Tomonao
    [J]. MATERIALS, 2023, 16 (03)
  • [7] Gentamicin-loaded discs and microspheres and their modifications: characterization and in vitro release
    Naraharisetti, PK
    Lew, MDN
    Fu, YC
    Lee, DJ
    Wang, CH
    [J]. JOURNAL OF CONTROLLED RELEASE, 2005, 102 (02) : 345 - 359
  • [8] Gentamicin-loaded bioresorbable films for prevention of bacterial infections associated with orthopedic implants
    Aviv, Moran
    Berdicevsky, Israela
    Zilberman, Meital
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 83A (01) : 10 - 19
  • [9] Corrosion resistance and antibacterial properties of hydroxyapatite coating induced by gentamicin-loaded polymeric multilayers on magnesium alloys
    Ji, Xiao-Jing
    Gao, Ling
    Liu, Jia-Cheng
    Wang, Jing
    Cheng, Qiang
    Li, Jian-Peng
    Li, Shuo-Qi
    Zhi, Ke-Qian
    Zeng, Rong-Chang
    Wang, Zhen-Lin
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 179 : 429 - 436
  • [10] Bactericidal properties and biocompatibility of a gentamicin-loaded Fe3O4/carbonated hydroxyapatite coating
    Tian, Bo
    Tang, Sha
    Wang, Chuan-Dong
    Wang, Wen-Gang
    Wu, Chuan-Long
    Guo, Ya-Jun
    Guo, Ya-Ping
    Zhu, Zhen-An
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 123 : 403 - 412