Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium

被引:62
|
作者
Stevanovic, Milena [1 ]
Dosic, Marija [2 ]
Jankovic, Ana [1 ]
Kojic, Vesna [3 ]
Vukasinovic-Sekulic, Maja [1 ]
Stojanovic, Jovica [2 ]
Odovic, Jadranka [4 ]
Sakasc, Milkica Crevar [4 ]
Rhee, Kyong Yop [5 ]
Miskovic-Stankovic, Vesna [1 ,5 ]
机构
[1] Univ Belgrade, Fac Technol & Met, Karnegijeva 4, Belgrade 11000, Serbia
[2] Inst Technol Nucl & Other Mineral Raw Mat ITNMS, Bulevar Frans dEperea 86, Belgrade 11000, Serbia
[3] Univ Novi Sad, Fac Med, Oncol Inst Vojvodina, Put Dr Goldmana 4, Sremska Kamenica 21204, Serbia
[4] Univ Belgrade, Fac Pharm, 450 Vojvode Stepe St, Belgrade 11000, Serbia
[5] Kyung Hee Univ, Dept Mech Engn, Yongin 449701, South Korea
来源
关键词
biocomposite; coatings; electrophoretic deposition; surface analysis; antibacterial activity; SILK FIBROIN COATINGS; ELECTROPHORETIC DEPOSITION; CARBONATED HYDROXYAPATITE; NANOCOMPOSITE COATINGS; STRUCTURAL-ANALYSIS; THERMAL-STABILITY; CHITOSAN COATINGS; BONE SUBSTITUTES; DRUG-RELEASE; CELL LINES;
D O I
10.1021/acsbiomaterials.8b00859
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed against Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic.
引用
收藏
页码:3994 / 4007
页数:27
相关论文
共 50 条
  • [1] Electrophoretic Deposition of Gentamicin-Loaded Bioactive Glass/Chitosan Composite Coatings for Orthopaedic Implants
    Pishbin, Fatemehsadat
    Mourino, Viviana
    Flor, Sabrina
    Kreppel, Stefan
    Salih, Vehid
    Ryan, Mary P.
    Boccaccini, Aldo R.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (11) : 8796 - 8806
  • [2] Electrophoretic Deposition of Gentamicin-Loaded ZnHNTs-Chitosan on Titanium
    Humayun, Ahmed
    Luo, Yangyang
    Mills, David K.
    [J]. COATINGS, 2020, 10 (10) : 1 - 18
  • [3] Assessing the Bioactivity of Gentamicin-Preloaded Hydroxyapatite/Chitosan Composite Coating on Titanium Substrate
    Stevanovic, Milena
    Djosic, Marija
    Jankovic, Ana
    Nesovic, Katarina
    Kojic, Vesna
    Stojanovic, Jovica
    Grujic, Svetlana
    Bujagic, Ivana Matic
    Rhee, Kyong Yop
    Miskovic-Stankovic, Vesna
    [J]. ACS OMEGA, 2020, 5 (25): : 15433 - 15445
  • [4] Novel bilayer coating on gentamicin-loaded titanium nanotube for orthopedic implants applications
    Shaygani, Hossein
    Seifi, Saeed
    Shamloo, Amir
    Golizadeh, Mortaza
    Rahnamaee, Seyed Yahya
    Alishiri, Mojgan
    Ebrahimi, Sina
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 636
  • [5] Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro
    Li, Liang-liang
    Wang, Li-ming
    Xu, Yan
    Lv, Lan-xin
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (06) : 897 - 903
  • [6] Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro
    Liang-liang Li
    Li-ming Wang
    Yan Xu
    Lan-xin Lv
    [J]. Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 897 - 903
  • [7] In Situ Potentiostatic Deposition of Calcium Phosphate with Gentamicin-Loaded Chitosan Nanoparticles on Titanium Alloy Surfaces
    Thomas, Midhun B.
    Metoki, Noah
    Mandler, Daniel
    Eliaz, Noam
    [J]. ELECTROCHIMICA ACTA, 2016, 222 : 355 - 360
  • [8] The chitosan-based bioactive composite coating on titanium
    Stevanovic, Milena
    Djosic, Marija
    Jankovic, Ana
    Kojic, Vesna
    Stojanovic, Jovica
    Grujic, Svetlana
    Bujagic, Ivana Matic
    Rhee, Kyong Yop
    Miskovic-Stankovic, Vesna
    [J]. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2021, 15 : 4461 - 4474
  • [9] Corrosion resistance and antibacterial properties of hydroxyapatite coating induced by gentamicin-loaded polymeric multilayers on magnesium alloys
    Ji, Xiao-Jing
    Gao, Ling
    Liu, Jia-Cheng
    Wang, Jing
    Cheng, Qiang
    Li, Jian-Peng
    Li, Shuo-Qi
    Zhi, Ke-Qian
    Zeng, Rong-Chang
    Wang, Zhen-Lin
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 179 : 429 - 436
  • [10] Gentamicin-loaded strontium-containing hydroxyapatite bioactive bone cement-An efficient bioactive antibiotic drug delivery system
    Liu, W. C.
    Wong, C. T.
    Fong, M. K.
    Cheung, W. S.
    Kao, R. Y. T.
    Luk, K. D. K.
    Lu, W. W.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (02) : 397 - 406