Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro

被引:36
|
作者
Li, Liang-liang [1 ]
Wang, Li-ming [1 ]
Xu, Yan [1 ]
Lv, Lan-xin [2 ]
机构
[1] Nanjing Med Univ, Dept Orthopaed, Nanjing Hosp 1, Nanjing 210006, Jiangsu, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Sch Biol Sci & Med Engn, Nanjing, Jiangsu, Peoples R China
关键词
Electrospinning; Gentamicin; Implant; Infection; NANOFIBROUS SCAFFOLDS; KNEE ARTHROPLASTY; INFECTION; BIOFILMS; RISK; HIP;
D O I
10.1007/s00402-012-1490-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Implant-related infections are disastrous complications in the clinic, and there are no effective therapies. In this preliminary study, gentamicin-loaded coating on titanium implants was prepared using the electrospinning technique, and some properties of the coating titanium implants were studied. We adopted the electrospinning technique to prepare gentamicin-coated titanium implants. The surface structure of the coating implants was observed using scanning electron microscope. An elution study was performed to determine the release behavior of the gentamicin from the coating. The antibacterial efficacy and quantitative analysis of the bacterial adhesion of were evaluated in vitro, and the cytotoxicity of the coated titanium implants on osteoblasts was investigated in vitro. The morphology of the gentamicin-coated titanium implants exhibited nanofibers, and the release of gentamicin showed an initial gentamicin burst followed by a slow release. The gentamicin-coated titanium implants had a persistent antibacterial efficacy for 1 week and significantly reduced the adhesion of the compared with bare titanium implants in vitro. There was no cytotoxicity observed in vitro for the gentamicin-coated implants. The gentamicin-coated titanium implants, which were prepared using an electrospinning technique, present many advantages and may be considered to prevent and treat the implant-related infections.
引用
收藏
页码:897 / 903
页数:7
相关论文
共 50 条
  • [31] In vitro anti-biofilm activity of a biphasic gentamicin-loaded calcium sulfate/hydroxyapatite bone graft substitute
    Butini, Maria Eugenia
    Cabric, Sabrina
    Trampuz, Andrej
    Di Luca, Mariagrazia
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2018, 161 : 252 - 260
  • [32] Tantalum-incorporated hydroxyapatite coating on titanium implants: its mechanical and in vitro osteogenic properties
    Lu, Rong-Jian
    Wang, Xing
    He, Hui-Xia
    E, Ling-Ling
    Li, Ying
    Zhang, Gui-Lan
    Li, Chuan-Jie
    Ning, Cheng-Yun
    Liu, Hong-Chen
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2019, 30 (10)
  • [33] Tantalum-incorporated hydroxyapatite coating on titanium implants: its mechanical and in vitro osteogenic properties
    Rong-Jian Lu
    Xing Wang
    Hui-Xia He
    Ling-Ling E
    Ying Li
    Gui-Lan Zhang
    Chuan-Jie Li
    Cheng-Yun Ning
    Hong-Chen Liu
    [J]. Journal of Materials Science: Materials in Medicine, 2019, 30
  • [34] Influence of lactose addition to gentamicin-loaded acrylic bone cement on the kinetics of release of the antibiotic and the cement properties
    Frutos, Gloria
    Ygnacio Pastor, Jose
    Martinez, Noelia
    Rosa Virto, Maria
    Torrado, Susana
    [J]. ACTA BIOMATERIALIA, 2010, 6 (03) : 804 - 811
  • [35] Gelatin-enhanced porous titanium loaded with gentamicin sulphate and in vitro release behavior
    Li, Qiuyan
    He, Guo
    [J]. MATERIALS & DESIGN, 2016, 99 : 459 - 466
  • [36] Preparation, characterization and in vitro release of chitosan nanoparticles loaded with gentamicin and salicylic acid
    Ji, Jingou
    Hao, Shilei
    Wu, Danjun
    Huang, Rui
    Xu, Yi
    [J]. CARBOHYDRATE POLYMERS, 2011, 85 (04) : 803 - 808
  • [37] BIODEGRADABLE GENTAMICIN-LOADED CONTROLLED RELEASE IMPLANTS MADE OF BETA-TRICALCIUM PHOSPHATE CERAMICS .1. STUDIES ON THE PREPARATION AND CHARACTERIZATION OF POROUS CERAMIC BETA-TRICALCIUM PHOSPHATE MATRICES
    THOMA, K
    ALEX, R
    [J]. PHARMAZIE, 1991, 46 (03): : 193 - 197
  • [38] Biocompatibility and antibacterial properties of zirconium nitride coating on titanium abutments: An in vitro study
    Brunello, Giulia
    Brun, Paola
    Gardin, Chiara
    Ferroni, Letizia
    Bressan, Eriberto
    Meneghello, Roberto
    Zavan, Barbara
    Sivolella, Stefano
    [J]. PLOS ONE, 2018, 13 (06):
  • [39] Multilayered coating of titanium implants promotes coupled osteogenesis and angiogenesis in vitro and in vivo
    Chen, Weizhen
    Xu, Kui
    Tao, Bailong
    Dai, Liangliang
    Yu, Yonglin
    Mu, Caiyun
    Shen, Xinkun
    Hu, Yan
    He, Ye
    Cai, Kaiyong
    [J]. ACTA BIOMATERIALIA, 2018, 74 : 489 - 504
  • [40] Coating titanium implants with bioglass and with hydroxyapatite -: A comparative study in sheep
    Lopez-Sastre, A
    Gonzalo-Orden, JM
    Altónaga, JAR
    Altónaga, JR
    Orden, MA
    [J]. INTERNATIONAL ORTHOPAEDICS, 1998, 22 (06) : 380 - 383