Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro

被引:36
|
作者
Li, Liang-liang [1 ]
Wang, Li-ming [1 ]
Xu, Yan [1 ]
Lv, Lan-xin [2 ]
机构
[1] Nanjing Med Univ, Dept Orthopaed, Nanjing Hosp 1, Nanjing 210006, Jiangsu, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Sch Biol Sci & Med Engn, Nanjing, Jiangsu, Peoples R China
关键词
Electrospinning; Gentamicin; Implant; Infection; NANOFIBROUS SCAFFOLDS; KNEE ARTHROPLASTY; INFECTION; BIOFILMS; RISK; HIP;
D O I
10.1007/s00402-012-1490-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Implant-related infections are disastrous complications in the clinic, and there are no effective therapies. In this preliminary study, gentamicin-loaded coating on titanium implants was prepared using the electrospinning technique, and some properties of the coating titanium implants were studied. We adopted the electrospinning technique to prepare gentamicin-coated titanium implants. The surface structure of the coating implants was observed using scanning electron microscope. An elution study was performed to determine the release behavior of the gentamicin from the coating. The antibacterial efficacy and quantitative analysis of the bacterial adhesion of were evaluated in vitro, and the cytotoxicity of the coated titanium implants on osteoblasts was investigated in vitro. The morphology of the gentamicin-coated titanium implants exhibited nanofibers, and the release of gentamicin showed an initial gentamicin burst followed by a slow release. The gentamicin-coated titanium implants had a persistent antibacterial efficacy for 1 week and significantly reduced the adhesion of the compared with bare titanium implants in vitro. There was no cytotoxicity observed in vitro for the gentamicin-coated implants. The gentamicin-coated titanium implants, which were prepared using an electrospinning technique, present many advantages and may be considered to prevent and treat the implant-related infections.
引用
收藏
页码:897 / 903
页数:7
相关论文
共 50 条
  • [21] In vitro study of collagen coating of titanium implants for initial cell attachment
    Nagai, M
    Hayakawa, T
    Fukatsu, A
    Yamamoto, M
    Fukumoto, M
    Nagahama, F
    Mishima, H
    Yoshinari, M
    Nemoto, K
    Kato, T
    [J]. DENTAL MATERIALS JOURNAL, 2002, 21 (03) : 250 - 260
  • [22] In vitro testing of chitosan in gentamicin-loaded bone cement No antimicrobial effect and reduced mechanical performance
    Dunne, Nicholas
    Buchanan, Fraser
    Hill, Janet
    Newe, Caroline
    Tunney, Michael
    Brady, Aaron
    Walker, Gavin
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (06) : 851 - 860
  • [23] Preparation and biological properties of BCZT/TiO2 electrokinetic conversion coating on titanium surface in vitro for dental implants
    Wu, Cong
    Zhang, Chun
    Yan, Xianyi
    Cheng, Junhua
    Chen, Lei
    Tang, Yufei
    Zhao, Kang
    [J]. SURFACE & COATINGS TECHNOLOGY, 2023, 468
  • [24] Gentamicin-Loaded Thermosetting Hydrogel and Moldable Composite Scaffold: Formulation Study and Biologic Evaluation
    Dorati, Rossella
    De Trizio, Antonella
    Genta, Ida
    Merelli, Alessia
    Modena, Tiziana
    Conti, Bice
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (06) : 1596 - 1607
  • [25] Rhamnolipid coating reduces microbial biofilm formation on titanium implants: an in vitro study
    Tambone, Erica
    Bonomi, Emiliana
    Ghensi, Paolo
    Maniglio, Devid
    Ceresa, Chiara
    Agostinacchio, Francesca
    Caciagli, Patrizio
    Nollo, Giandomenico
    Piccoli, Federico
    Caola, Iole
    Fracchia, Letizia
    Tessarolo, Francesco
    [J]. BMC ORAL HEALTH, 2021, 21 (01)
  • [26] Rhamnolipid coating reduces microbial biofilm formation on titanium implants: an in vitro study
    Erica Tambone
    Emiliana Bonomi
    Paolo Ghensi
    Devid Maniglio
    Chiara Ceresa
    Francesca Agostinacchio
    Patrizio Caciagli
    Giandomenico Nollo
    Federico Piccoli
    Iole Caola
    Letizia Fracchia
    Francesco Tessarolo
    [J]. BMC Oral Health, 21
  • [27] A functional coating to enhance antibacterial and bioactivity properties of titanium implants and its performance in vitro
    Doymus, Burcu
    Kerem, Gizem
    Yazgan Karatas, Ayten
    Kok, Fatma Nese
    Onder, Sakip
    [J]. JOURNAL OF BIOMATERIALS APPLICATIONS, 2021, 35 (06) : 655 - 669
  • [28] Gentamicin-loaded carbonated hydroxyapatite coatings with hierarchically porous structures: drug delivery properties, bactericidal properties and biocompatibility
    Tang, Sha
    Tian, Bo
    Ke, Qin-Fei
    Zhu, Zhen-An
    Guo, Ya-Ping
    [J]. RSC ADVANCES, 2014, 4 (78): : 41500 - 41509
  • [29] PHARMACOKINETIC STUDY OF GENTAMICIN-LOADED CEMENT IN TOTAL HIP REPLACEMENTS - COMPARATIVE EFFECTS OF VARYING DOSAGE
    WAHLIG, H
    DINGELDEIN, E
    BUCHHOLZ, HW
    BUCHHOLZ, M
    BACHMANN, F
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (02): : 175 - 179
  • [30] Preparation and antibacterial properties of BCZT-Ag piezoelectric coating on titanium surface for orthopedic implants
    Wu, Cong
    Zhang, Chun
    Yan, Xianyi
    Liang, Qian
    Zhao, Kang
    Tang, Yufei
    [J]. CERAMICS INTERNATIONAL, 2024, 50 (03) : 4296 - 4306