Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for Caesarean delivery

被引:51
|
作者
Ngan Kee, W. D. [1 ]
Khaw, K. S. [1 ]
Ng, F. F. [1 ]
Tam, Y. H. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
关键词
anaesthesia; spinal; arterial pressure; hypotension; Caesarean delivery; BLOOD-PRESSURE; PERFORMANCE; HYPOTENSION;
D O I
10.1093/bja/aes339
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Closed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for Caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system. We randomly allocated 222 healthy subjects having spinal anaesthesia for scheduled Caesarean delivery to have systolic AP maintained near baseline with phenylephrine (100 g ml(1)) by computer-controlled infusion utilizing a proportional algorithm or manual-controlled infusion utilizing an onoff algorithm. AP control was assessed by comparing the proportion of systolic AP measurements within 20 of baseline and by performance error (PE) calculations. A total of 212 subjects finished the study. In the computer-control group, 97 of systolic AP recordings fell within 20 of baseline compared with 95 in the manual-control group (P0.0004). For computer-control compared with manual-control, wobble was smaller [median 3.5 (inter-quartile range 2.54.8) vs 4.2 (3.35.9), P0.003], but there was no difference in the median PE [2.9 (0.34.7) vs 1.9 (04.2)], median absolute PE [4.7 (3.55.6) vs 4.7 (3.86.7)], or divergence [0.01 (0.030) vs 0.06 (0.260.08)]. Fewer interventions per subject for controlling AP were required in the computer-control group [2 (22) vs 10 (813), P0.001]. There were no differences in measured clinical outcomes. Within the constraints of the studied algorithms, closed-loop feedback computer-controlled phenylephrine infusion provided better AP control with fewer interventions required compared with manual-controlled infusion.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [41] Manually Controlled, Continuous Infusion of Phenylephrine or Norepinephrine for Maintenance of Blood Pressure and Cardiac Output During Spinal Anesthesia for Cesarean Delivery: A Double-Blinded Randomized Study
    Belin, Olivier
    Casteres, Charlotte
    Alouini, Souhail
    Le Pape, Marc
    Dupont, Abderrahmane
    Boulain, Thierry
    ANESTHESIA AND ANALGESIA, 2023, 136 (03): : 540 - 550
  • [42] Comparison of carbetocin as a bolus or an infusion with prophylactic phenylephrine on maternal heart rate during Cesarean delivery under spinal anesthesia: a double-blinded randomized controlled trial
    Boisselle, Marie-Eve
    Zaphiratos, Valerie Vasiliki
    Fortier, Annik
    Richebe, Philippe
    Loubert, Christian
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2022, 69 (06): : 715 - 725
  • [43] A Randomized Controlled Trial of Variable Rate Phenylephrine Infusion With Rescue Phenylephrine Boluses Versus Rescue Boluses Alone on Physician Interventions During Spinal Anesthesia for Elective Cesarean Delivery
    Siddik-Sayyid, Sahar M.
    Taha, Samar K.
    Kanazi, Ghassan E.
    Aouad, Marie T.
    ANESTHESIA AND ANALGESIA, 2014, 118 (03): : 611 - 618
  • [44] Six Months of Hybrid Closed-Loop Versus Manual Insulin Delivery With Fingerprick Blood Glucose Monitoring in Adults With Type 1 Diabetes: A Randomized, Controlled Trial
    McAuley, Sybil A.
    Lee, Melissa H.
    Paldus, Barbora
    Vogrin, Sara
    de Bock, Martin I.
    Abraham, Mary B.
    Bach, Leon A.
    Burt, Morton G.
    Cohen, Neale D.
    Colman, Peter G.
    Davis, Elizabeth A.
    Hendrieckx, Christel
    Holmes-Walker, D. Jane
    Kaye, Joey
    Keech, Anthony C.
    Kumareswaran, Kavita
    MacIsaac, Richard J.
    McCallum, Roland W.
    Sims, Catriona M.
    Speight, Jane
    Stranks, Stephen N.
    Sundararajan, Vijaya
    Trawley, Steven
    Ward, Glenn M.
    Jenkins, Alicia J.
    Jones, Timothy W.
    O'Neal, David N.
    DIABETES CARE, 2020, 43 (12) : 3024 - 3033
  • [45] Hemodynamics of Phenylephrine Infusion Versus Lower Extremity Compression During Spinal Anesthesia for Cesarean Delivery: A Randomized, Double-Blind, Placebo-Controlled Study
    Kuhn, Jana Christine
    Hauge, Tor Hugo
    Rosseland, Leiv Arne
    Dahl, Vegard
    Langesaeter, Eldrid
    ANESTHESIA AND ANALGESIA, 2016, 122 (04): : 1120 - 1129
  • [46] Comparison of Cambridge closed-loop algorithm (CAM) performance in automated and manual control centres during 23h of day and night closed-loop insulin delivery in a randomized crossover study in subjects with Type 1 diabetes
    Leelarathna, L.
    Avogaro, A.
    Benesch, C.
    Bruttomesso, D.
    Caldwell, K.
    Cobelli, C.
    DeVries, J. H.
    Evans, M. L.
    Hovorka, R.
    DIABETIC MEDICINE, 2013, 30 : 15 - 15
  • [47] Comparison Between Closed-Loop Insulin Delivery System (the Artificial Pancreas) and Sensor-Augmented Pump Therapy: A Randomized-Controlled Crossover Trial
    Haidar, Ahmad
    Legault, Laurent
    Raffray, Marie
    Gouchie-Provencher, Nikita
    Jacobs, Peter G.
    El-Fathi, Anas
    Rutkowski, Joanna
    Messier, Virginie
    Rabasa-Lhoret, Remi
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (03) : 168 - 174
  • [48] Comparison of Two Isoflurane Delivery Systems for Maintaining Anesthesia in Horses: End-Tidal Closed-Loop Target-Controlled Versus Out-Of-Circuit Vaporizer
    Levorato, Silvia
    Franci, Paolo
    Contiero, Barbara
    Busetto, Roberto
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2016, 37 : 63 - 70
  • [49] Tight control of mean arterial pressure using a closed loop system for norepinephrine infusion after high-risk abdominal surgery: a randomized controlled trial
    Sean Coeckelenbergh
    Maxim Soucy-Proulx
    Philippe Van der Linden
    Matthieu Clanet
    Joseph Rinehart
    Maxime Cannesson
    Jacques Duranteau
    Alexandre Joosten
    Journal of Clinical Monitoring and Computing, 2024, 38 : 19 - 24
  • [50] Tight control of mean arterial pressure using a closed loop system for norepinephrine infusion after high-risk abdominal surgery: a randomized controlled trial
    Coeckelenbergh, Sean
    Soucy-Proulx, Maxim
    van der Linden, Philippe
    Clanet, Matthieu
    Rinehart, Joseph
    Cannesson, Maxime
    Duranteau, Jacques
    Joosten, Alexandre
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 19 - 24