Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for Caesarean delivery

被引:51
|
作者
Ngan Kee, W. D. [1 ]
Khaw, K. S. [1 ]
Ng, F. F. [1 ]
Tam, Y. H. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
关键词
anaesthesia; spinal; arterial pressure; hypotension; Caesarean delivery; BLOOD-PRESSURE; PERFORMANCE; HYPOTENSION;
D O I
10.1093/bja/aes339
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Closed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for Caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system. We randomly allocated 222 healthy subjects having spinal anaesthesia for scheduled Caesarean delivery to have systolic AP maintained near baseline with phenylephrine (100 g ml(1)) by computer-controlled infusion utilizing a proportional algorithm or manual-controlled infusion utilizing an onoff algorithm. AP control was assessed by comparing the proportion of systolic AP measurements within 20 of baseline and by performance error (PE) calculations. A total of 212 subjects finished the study. In the computer-control group, 97 of systolic AP recordings fell within 20 of baseline compared with 95 in the manual-control group (P0.0004). For computer-control compared with manual-control, wobble was smaller [median 3.5 (inter-quartile range 2.54.8) vs 4.2 (3.35.9), P0.003], but there was no difference in the median PE [2.9 (0.34.7) vs 1.9 (04.2)], median absolute PE [4.7 (3.55.6) vs 4.7 (3.86.7)], or divergence [0.01 (0.030) vs 0.06 (0.260.08)]. Fewer interventions per subject for controlling AP were required in the computer-control group [2 (22) vs 10 (813), P0.001]. There were no differences in measured clinical outcomes. Within the constraints of the studied algorithms, closed-loop feedback computer-controlled phenylephrine infusion provided better AP control with fewer interventions required compared with manual-controlled infusion.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [31] Oxygen delivery, oxygen consumption, and gastric intramucosal pH are not improved by a computer-controlled, closed-loop, vecuronium infusion in severe sepsis and septic shock
    Freebairn, RC
    Derrick, J
    Gomersall, CD
    Young, RJ
    Joynt, GM
    CRITICAL CARE MEDICINE, 1997, 25 (01) : 72 - 77
  • [32] COMPARISON OF TARGET CONTROL INFUSION AND MANUAL INFUSION FOR DELIVERY OF PROPOFOL MAINTAINED ANAESTHESIA IN CHILDREN: A PROSPECTIVE RANDOMIZED CONTROLLED STUDY
    Jingjing, M.
    Yuen, V. M.
    Irwin, M. G.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 318 - 319
  • [33] BIS feedback closed-loop target-controlled infusion of propofol or etomidate in elderly patients with spinal surgery
    Zheng, Zhonglei
    Su, Yuqiang
    Fan, Xiaoying
    Zhang, Wanping
    Li, Jing
    Xue, Sha
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (02): : 1231 - 1238
  • [34] Control of mean arterial pressure using a closed-loop system for norepinephrine infusion in severe brain injury patients: the COMAT randomized controlled trial
    Joosten, Alexandre
    Rinehart, Joseph
    Cannesson, Maxime
    Coeckelenbergh, Sean
    Pochard, Jonas
    Vicaut, Eric
    Duranteau, Jacques
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 25 - 30
  • [35] Control of mean arterial pressure using a closed-loop system for norepinephrine infusion in severe brain injury patients: the COMAT randomized controlled trial
    Alexandre Joosten
    Joseph Rinehart
    Maxime Cannesson
    Sean Coeckelenbergh
    Jonas Pochard
    Eric Vicaut
    Jacques Duranteau
    Journal of Clinical Monitoring and Computing, 2024, 38 : 25 - 30
  • [36] Closed-loop control of propofol anaesthesia using bispectral index™:: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanil infusions for minor surgery
    Absalom, AR
    Kenny, GNC
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (06) : 737 - 741
  • [37] Randomised double-blinded comparison of phenylephrine vs ephedrine for maintaining blood pressure during spinal anaesthesia for non-elective Caesarean section
    Ngan Kee, W. D.
    Khaw, K. S.
    Lau, T. K.
    Ng, F. F.
    Chui, K.
    Ng, K. L.
    ANAESTHESIA, 2008, 63 (12) : 1319 - 1326
  • [38] HYPERTENSIVE CRISIS MANAGED BY COMPUTER-CONTROLLED INFUSION OF SODIUM-NITROPRUSSIDE - MODEL FOR THE CLOSED-LOOP ADMINISTRATION OF SHORT-ACTING VASOACTIVE AGENTS
    HAMMOND, JJ
    KIRKENDALL, WM
    CALFEE, RV
    COMPUTERS AND BIOMEDICAL RESEARCH, 1979, 12 (02): : 97 - 108
  • [39] An open-label randomized controlled clinical trial for comparison of continuous phenylephrine versus norepinephrine infusion in prevention of spinal hypotension during cesarean delivery
    Vallejo, M. C.
    Attaallah, A. F.
    Elzamzamy, O. M.
    Cifarelli, D. T.
    Phelps, A. L.
    Hobbs, G. R.
    Shapiro, R. E.
    Ranganathan, P.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2017, 29 : 18 - 25
  • [40] Comparison of Prophylactic Norepinephrine and Phenylephrine Infusions During Spinal Anaesthesia for Primary Caesarean Delivery in Twin Pregnancies: A Randomized Double-Blinded Clinical Study
    Du, Weijia
    Song, Yujie
    Li, Jiang
    Zhou, Xianjin
    Xu, Zhendong
    Liu, Zhiqiang
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2022, 16 : 789 - 798