Comparison Between Closed-Loop Insulin Delivery System (the Artificial Pancreas) and Sensor-Augmented Pump Therapy: A Randomized-Controlled Crossover Trial

被引:14
|
作者
Haidar, Ahmad [1 ,2 ]
Legault, Laurent [3 ,4 ]
Raffray, Marie [5 ]
Gouchie-Provencher, Nikita [2 ]
Jacobs, Peter G. [6 ]
El-Fathi, Anas [1 ]
Rutkowski, Joanna [1 ]
Messier, Virginie [5 ]
Rabasa-Lhoret, Remi [5 ,7 ,8 ,9 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[2] McGill Univ, Ctr Translat Biol, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[3] McGill Univ, Dept Pediat, Div Endocrinol & Metab, Hlth Ctr, Montreal, PQ, Canada
[4] McGill Univ, Ctr Outcomes Res & Evaluat, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[5] Inst Rech Clin Montreal, Metab Dis Res Unit, 110 Ave Pins Ouest, Montreal, PQ H2W 1R7, Canada
[6] Oregon Hlth & Sci Univ, Dept Biomed Engn, Portland, OR 97201 USA
[7] Univ Montreal, Fac Med, Nutr Dept, Montreal, PQ, Canada
[8] Montreal Diabet Res Ctr, Montreal, PQ, Canada
[9] Endocrinol Div, Montreal, PQ, Canada
关键词
Closed-loop; Artificial pancreas; Randomized-controlled trial; Sensor-augmented pump therapy; OPEN-LABEL; GLUCOSE CONTROL; TYPE-1; ADULTS; ADOLESCENTS;
D O I
10.1089/dia.2020.0365
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Several studies have shown that closed-loop automated insulin delivery (the artificial pancreas) improves glucose control compared with sensor-augmented pump therapy. We aimed to confirm these findings using our automated insulin delivery system based on the iPancreas platform. Research Design and Methods: We conducted a two-center, randomized crossover trial comparing automated insulin delivery with sensor-augmented pump therapy in 36 adults with type 1 diabetes. Each intervention lasted 12 days in outpatient free-living conditions with no remote monitoring. The automated insulin delivery system used a model predictive control algorithm that was a less aggressive version of our earlier dosing algorithm to emphasize safety. The primary outcome was time in the range 3.9-10.0 mmol/L. Results: The automated insulin delivery system was operational 90.2% of the time. Compared with the sensor-augmented pump therapy, automated insulin delivery increased time in range (3.9-10.0 mmol/L) from 61% (interquartile range 53-74) to 69% (60-73; P = 0.006) and increased time in tight target range (3.9-7.8 mmol/L) from 37% (30-49) to 45% (35-51; P = 0.011). Automated insulin delivery also reduced time spent below 3.9 and 3.3 mmol/L from 3.5% (0.8-5.4) to 1.6% (1.1-2.7; P = 0.0021) and from 0.9% (0.2-2.1) to 0.5% (0.2-1.1; P = 0.0122), respectively. Time spent below 2.8 mmol/L was 0.2% (0.0-0.6) with sensor-augmented pump therapy and 0.1% (0.0-0.4; P = 0.155) with automated insulin delivery. Conclusions: Our study confirms findings that automated insulin delivery improves glucose control compared with sensor-augmented pump therapy. ClinicalTrials.gov no. NCT02846831.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [1] Closed-Loop Insulin Delivery Versus Sensor-Augmented Pump Therapy in Older Adults With Type 1 Diabetes (ORACL): A Randomized, Crossover Trial
    McAuley, Sybil A. A.
    Trawley, Steven
    Vogrin, Sara
    Ward, Glenn M. M.
    Fourlanos, Spiros
    Grills, Charlotte A. A.
    Lee, Melissa H. H.
    Alipoor, Andisheh Mohammad
    O'Neal, David N. N.
    O'Regan, Niamh A. A.
    Sundararajan, Vijaya
    Colman, Peter G. G.
    MacIsaac, Richard J. J.
    DIABETES CARE, 2022, 45 (02) : 381 - 390
  • [2] Randomized Trial of Assisted Hybrid Closed-Loop Therapy Versus Sensor-Augmented Pump Therapy in Pregnancy
    Polsky, Sarit
    Buschur, Elizabeth
    Dungan, Kathleen
    Garcetti, Rachel
    Nease, Emily
    Malecha, Emily
    Bartholomew, Anna
    Johnson, Carly
    Pyle, Laura
    Snell-Bergeon, Janet
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (08) : 547 - 555
  • [3] Closed-Loop Increases Time-in-Range in Older Adults with Type 1 Diabetes Compared with Sensor-Augmented Pump Therapy: A Randomized Crossover Trial
    Mcauley, Sybil A.
    Vogrin, Sara
    Trawley, Steven
    Colman, Peter G.
    Fourlanos, Spiros
    Grills, Charlotte
    Lee, Melissa H.
    Alipoor, Andisheh Mohammad
    O'Neal, David N.
    O'Regan, Niamh A.
    Sundararajan, Vijaya
    Ward, Glenn M.
    Macisaac, Richard
    DIABETES, 2021, 70
  • [4] Efficacy and safety of closed-loop insulin delivery versus sensor-augmented pump in the treatment of adults with type 1 diabetes: a systematic review and meta-analysis of randomized-controlled trials
    Z. Fang
    M. Liu
    J. Tao
    C. Li
    F. Zou
    W. Zhang
    Journal of Endocrinological Investigation, 2022, 45 : 471 - 481
  • [5] Efficacy and safety of closed-loop insulin delivery versus sensor-augmented pump in the treatment of adults with type 1 diabetes: a systematic review and meta-analysis of randomized-controlled trials
    Fang, Z.
    Liu, M.
    Tao, J.
    Li, C.
    Zou, F.
    Zhang, W.
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2022, 45 (03) : 471 - 481
  • [6] A randomised clinical trial comparing the efficacy of a hybrid closed-loop automated insulin delivery system with a sensor-augmented disposable patch pump in type 1 diabetes
    Kim, J.
    Jin, S. -M.
    Kang, E.
    Kwak, S.
    Yang, Y.
    Yoo, J.
    Bae, J.
    Moon, J.
    Jung, C.
    Bae, J.
    Suh, S.
    Moon, S.
    Song, S.
    Chon, S.
    Kim, J.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S388 - S388
  • [7] Outpatient Randomized Crossover Comparison of Zone Model Predictive Control Automated Insulin Delivery with Weekly Data Driven Adaptation Versus Sensor-Augmented Pump: Results from the International Diabetes Closed-Loop Trial 4
    Pinsker, Jordan E.
    Dassau, Eyal
    Deshpande, Sunil
    Raghinaru, Dan
    Buckingham, Bruce A.
    Kudva, Yogish C.
    Laffel, Lori M.
    Levy, Carol J.
    Church, Mei Mei
    Desrochers, Hannah
    Ekhlaspour, Laya
    Kaur, Ravinder Jeet
    Levister, Camilla
    Shi, Dawei
    Lum, John W.
    Kollman, Craig
    Doyle, Francis J.
    iDCL Trial Res Grp
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (09) : 635 - 642
  • [8] A Randomised Controlled Cross-Over Trial of the Hybrid Closed-Loop Insulin Delivery System Diabeloop vs. Sensor-Augmented Pump Therapy in Children Aged 6-12 Years
    Kariyawasam, Dulanjalee
    Morin, Carole
    Casteels, Kristina
    Le Tallec, Claire
    Sfez, Annie
    Godot, Cecile
    Huneker, Erik
    Garrec, Nathalie
    Polak, Michel
    Charpentier, Guillaume
    Franc, Sylvia
    Beltrand, Jacques
    HORMONE RESEARCH IN PAEDIATRICS, 2021, 94 (SUPPL 1): : 37 - 37
  • [9] HYPOGLYCAEMIA OCCURENCE AND RECOVERY DURING HOME USE OF CLOSED-LOOP INSULIN DELIVERY AND SENSOR-AUGMENTED PUMP THERAPY IN ADULTS WITH TYPE 1 DIABETES
    Ruan, Y.
    Bally, L.
    Thabit, H.
    Mader, J.
    Kojzar, H.
    Dellweg, S.
    Benesch, C.
    Hartnell, S.
    Leelarathna, L.
    Wilinska, M.
    Evans, M.
    Arnolds, S.
    Pieber, T.
    Hovorka, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A59 - A60
  • [10] Changes to insulin pump settings throughout pregnancy for individuals using assisted hybrid closed-loop therapy versus sensor-augmented pump therapy
    King, Jocelynn
    Buschur, Elizabeth
    Garcetti, Rachel
    Pyle, Laura
    Sakamoto, Casey
    Snell-Bergeon, Janet
    Nease, Emily
    Bartholomew, Anna
    Dungan, Kathleen
    Polsky, Sarit
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2025, 39 (04)