Failure analysis of isolation valve stems in steam generator blow down system

被引:5
|
作者
Jung, Yong Chan [1 ]
Lee, Tae Hee [1 ]
Kim, Min Tae [1 ]
机构
[1] Korea Elect Power Res Inst, Taejon 305380, South Korea
关键词
Isolation valve; Stem failure; Full annealing; Mechanical properties;
D O I
10.1016/j.engfailanal.2013.03.006
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Two isolation valves failed prematurely in the steam generator blow down system of a nuclear power plant. Metallurgical analysis of the damaged stems in the isolation valves was made. Heat treatment tests were carried out to verify the reliability of stems in comparison with the required mechanical specifications. The results of the analysis showed the abnormal precipitation of nonmetallic inclusions, MnS, in the matrix. These nonmetallic inclusions which could acts as notches were distributed randomly to 0.2 vol.%, two times higher than those of typical materials. In addition, the hardness of the damaged stems was twofold higher and the elongation was reduced by half compared to those values attainable from a proper full annealing. It is concluded that improper tempering applied to the damaged stems resulted in second hardening and decrease in toughness, consequently shortening the life of the stems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 50 条
  • [31] Analysis of Passive Heat Removal System through Steam Generator by ANSYS Fluent
    Petrosyan, Taron
    Katovsky, Karel
    Suk, Ladislav
    PROCEEDINGS OF THE 23RD INTERNATIONAL SCIENTIFIC CONFERENCE OF YOUNG SCIENTISTS AND SPECIALISTS (AYSS-2019), 2019, 2163
  • [32] Improvement of steam generator tube failure propagation analysis code LEAP for evaluation of overheating rupture
    Uchibori, Akihiro
    Yanagisawa, Hideki
    Takata, Takashi
    Kurihara, Akikazu
    Hamada, Hirotsugu
    Ohshima, Hiroyuki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2019, 56 (02) : 201 - 209
  • [33] Root Cause Failure Analysis of a Heat Recovery Steam Generator (HRSG) Condensate Preheater Tube
    Manzoor, Awais
    Saleem, Osama
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, 24 (06) : 2771 - 2786
  • [34] FAILURE ANALYSIS OF THE TMI-1 ONCE-THROUGH STEAM-GENERATOR TUBES
    LONG, RL
    JONES, JD
    GIACOBBE, FS
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 327 - 328
  • [35] Failure analysis on unexpected fracture of tube-to-tubesheet joints of a circulating oil steam generator
    He, Xiaofeng
    Wang, Jielu
    Lu, Xuemei
    Song, Qixiang
    Su, Wenxian
    ENGINEERING FAILURE ANALYSIS, 2023, 154
  • [36] Fracture failure analysis of steam generator channel heads with high carbon macro-segregation
    Shi, Kaikai
    Zhang, Yixiong
    Yang, Yu
    Zheng, Bin
    Xie, Hai
    Gao, Shiqing
    Bai, Xiaoming
    Fu, Xiaolong
    Shao, Xuejiao
    ENGINEERING FAILURE ANALYSIS, 2020, 113 (113)
  • [37] Program development for performance analysis of a steam turbine system with the use of overload valve
    Soo Young Kang
    Jeong Jin Lee
    Tong Seop Kim
    Seong Jin Park
    Gi Won Hong
    Jun Ho Ahn
    Journal of Mechanical Science and Technology, 2016, 30 : 5759 - 5769
  • [38] Program development for performance analysis of a steam turbine system with the use of overload valve
    Kang, Soo Young
    Lee, Jeong Jin
    Kim, Tong Seop
    Park, Seong Jin
    Hong, Gi Won
    Ahn, Jun Ho
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (12) : 5759 - 5769
  • [39] Failure analysis of an overhead valve train system in urban buses
    Velez Godino, Jose Antonio
    Torres Garcia, Miguel
    Jimenez-Espadafor Aguilar, Francisco Jose
    Palomo Guerrero, Daniel
    ENGINEERING FAILURE ANALYSIS, 2019, 96 : 455 - 467
  • [40] Implementation of Failure Modes and Effect Analysis on the Electro-Hydraulic Servo Valve for Steam Turbine
    Banerjee, Priya
    Pandey, Kamlesh
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,