Root Cause Failure Analysis of a Heat Recovery Steam Generator (HRSG) Condensate Preheater Tube

被引:0
|
作者
Manzoor, Awais [1 ]
Saleem, Osama [1 ]
机构
[1] PetroMaster Co Ltd, Taawun Dist 346326289, Al Khobar, Saudi Arabia
关键词
HRSG; Condensate preheater tube; Economizer; Dew point corrosion; Fractography;
D O I
10.1007/s11668-024-02040-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This investigation delves into the metallurgical root cause failure analysis of a leaking heat recovery steam generator (HRSG) condensate preheater tube from a combined cycle power plant. The CPH tube experienced failure in the form of multiple pinholes, resulting in leakage. Detailed visual examination, dimensional measurements, metallographic examination, hardness testing, chemical analysis, EDS analysis and x-ray diffraction analysis elucidated the damage mechanism as acid dew point corrosion. Findings indicated severe corrosion attack by sulfuric acid formation on the tube's exterior, corroborated by the presence of iron sulfate in deposits and high sulfur content. Furthermore, recommendations were also given to avoid the recurrence of similar failures.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Corrosion Failure Analysis of Condensate Pre-Heater in Heat Recovery Steam Generator
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Kim, Kyung Min
    Lee, Soo Yeol
    [J]. CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (02): : 69 - 76
  • [2] Parametric Evaluation of Heat Recovery Steam Generator (HRSG)
    Sharma, Meeta
    Singh, Onkar
    [J]. HEAT TRANSFER-ASIAN RESEARCH, 2014, 43 (08): : 691 - 705
  • [3] Root Cause Failure Analysis of Superheated Steam Tube at a Petrochemical Plant
    Hosseini, Reza Khadem
    [J]. ECF22 - LOADING AND ENVIRONMENTAL EFFECTS ON STRUCTURAL INTEGRITY, 2018, 13 : 232 - 237
  • [4] Root cause analysis of the failure of the steam generator orifice assembly of a test reactor
    Albert, Shaju K.
    Kumar, R. Suresh
    Kumar, Hemant
    Kumar, R. Nanda
    Toppo, Anita
    Poonguzhali, A.
    Elango, M.
    Babu, A.
    [J]. ENGINEERING FAILURE ANALYSIS, 2021, 129
  • [5] Root cause analysis of evaporator tubes failure of a HRSG unit
    Gupta, Jeetendra
    Kujur, Abhay
    Talukdar, Maushmi K.
    Velusshami, S. K.
    Prasad, Sangeeta R.
    Bhatia, Bharti
    Sharma, Anita
    Bhardwaj, Anil
    [J]. ENGINEERING FAILURE ANALYSIS, 2019, 97 : 322 - 330
  • [6] Performance improvement of heat recovery steam generator (HRSG) in combined cycle power plant by replacing tube of HP economizer and HP evaporator
    Adi, Waskito
    Caesarendra, Wahyu
    [J]. 2021 11TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2021), 2021, : 266 - 271
  • [7] Root Cause Analysis of Steam Turbine Blade Failure
    M. C. Antony Harison
    M. Swamy
    A. H. V. Pavan
    G. Jayaraman
    [J]. Transactions of the Indian Institute of Metals, 2016, 69 : 659 - 663
  • [8] Root Cause Analysis of Steam Turbine Blade Failure
    Harison, M. C. Antony
    Swamy, M.
    Pavan, A. H. V.
    Jayaraman, G.
    [J]. TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2016, 69 (02) : 659 - 663
  • [9] Experimental Investigation of the Heat Transfer in a Feedwater Preheater for the Decarbonizing Steam Generator
    Kolonicny, Jan
    Kupka, David
    Jandacka, Jozef
    [J]. PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 1129 - 1134
  • [10] ROOT CAUSE ANALYSIS OF GENERATOR ROTOR ENDWINDING FAILURE
    Piao, Jinghu
    Park, Sangho
    Park, Hyun Ku
    [J]. PROCEEDINGS OF THE 2010 INTERNATIONAL CONFERENCE ON MECHANICAL, INDUSTRIAL, AND MANUFACTURING TECHNOLOGIES (MIMT 2010), 2010, : 123 - 124