Root Cause Failure Analysis of a Heat Recovery Steam Generator (HRSG) Condensate Preheater Tube

被引:0
|
作者
Manzoor, Awais [1 ]
Saleem, Osama [1 ]
机构
[1] PetroMaster Co Ltd, Taawun Dist 346326289, Al Khobar, Saudi Arabia
关键词
HRSG; Condensate preheater tube; Economizer; Dew point corrosion; Fractography;
D O I
10.1007/s11668-024-02040-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This investigation delves into the metallurgical root cause failure analysis of a leaking heat recovery steam generator (HRSG) condensate preheater tube from a combined cycle power plant. The CPH tube experienced failure in the form of multiple pinholes, resulting in leakage. Detailed visual examination, dimensional measurements, metallographic examination, hardness testing, chemical analysis, EDS analysis and x-ray diffraction analysis elucidated the damage mechanism as acid dew point corrosion. Findings indicated severe corrosion attack by sulfuric acid formation on the tube's exterior, corroborated by the presence of iron sulfate in deposits and high sulfur content. Furthermore, recommendations were also given to avoid the recurrence of similar failures.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Dynamic simulation of a hybrid once-through and natural circulation Heat Recovery Steam Generator (HRSG)
    Farahani, Yaser
    Jafarian, Ali
    Keshavar, Omid Mahdavi
    [J]. ENERGY, 2022, 242
  • [22] Analysis of Root Cause of Failure of a Turbo Generator Stator Winding
    Puhan, Dillip Kumar
    Thirumurthy
    Sharma, Rajat
    Meena, K. P.
    [J]. PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 84 - 90
  • [23] On the Failure Analysis of an Air Preheater in a Steam Power Plant
    Shayan M.R.
    Ranjbar K.
    Hajidavalloo E.
    Heidari Kydan A.
    [J]. J. Fail. Anal. Prev, 6 (941-951): : 941 - 951
  • [24] ON THE USE OF COMPUTATIONAL FLUID DYNAMICS (CFD) TO ASSESS THE IMPACT OF LOW-LOAD OPERATIONS ON HEAT RECOVERY STEAM GENERATOR (HRSG) TUBE MODULE INTEGRITY
    Fabricius, Andreas
    Moelling, David S.
    Rusaas, Jan
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE, 2019, 2019,
  • [25] Failure Analysis of Once-Through Steam Generator (OTSG) Tube
    Tina, Wahida
    Donaldson, Elizabeth
    Dickinson, Thomas E.
    Schmidt, William Hal
    [J]. ASME Open Journal of Engineering, 2023, 2
  • [26] Failure analysis of a steam generator superheater drain tube used in a dump
    Cicero, S.
    Lacalle, R.
    Cicero, R.
    Garcia, J.
    [J]. ENGINEERING FAILURE ANALYSIS, 2010, 17 (01) : 301 - 312
  • [27] Degradation Evaluation of High-Pressure Superheater Tube in Heat Recovery Steam Generator
    Song, Min Ji
    Choi, Gahyun
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Lee, Soo Yeol
    [J]. CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2022, 21 (02): : 130 - 137
  • [28] A study of natural circulation in the evaporator of a horizontal-tube heat recovery steam generator
    Roslyakov P.V.
    Pleshanov K.A.
    Sterkhov K.V.
    [J]. Thermal Engineering, 2014, 61 (7) : 465 - 472
  • [29] Sensitivity Analysis of Heat Transfer Tube Plug Structure of Steam Generator
    Li, Jinghuai
    Han, Yile
    Zhou, Quan
    Ying, Bingbin
    Chao, Mengke
    Yang, Xing
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (05): : 181 - 187
  • [30] Investigation of Probable Cause of Premature Cracking of Downcomer Nozzle of Heat Recovery Steam Generator
    Ghosh, D.
    Roy, H.
    Shukla, A. K.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2009, 9 (06) : 517 - 521