Root Cause Failure Analysis of a Heat Recovery Steam Generator (HRSG) Condensate Preheater Tube

被引:0
|
作者
Manzoor, Awais [1 ]
Saleem, Osama [1 ]
机构
[1] PetroMaster Co Ltd, Taawun Dist 346326289, Al Khobar, Saudi Arabia
关键词
HRSG; Condensate preheater tube; Economizer; Dew point corrosion; Fractography;
D O I
10.1007/s11668-024-02040-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This investigation delves into the metallurgical root cause failure analysis of a leaking heat recovery steam generator (HRSG) condensate preheater tube from a combined cycle power plant. The CPH tube experienced failure in the form of multiple pinholes, resulting in leakage. Detailed visual examination, dimensional measurements, metallographic examination, hardness testing, chemical analysis, EDS analysis and x-ray diffraction analysis elucidated the damage mechanism as acid dew point corrosion. Findings indicated severe corrosion attack by sulfuric acid formation on the tube's exterior, corroborated by the presence of iron sulfate in deposits and high sulfur content. Furthermore, recommendations were also given to avoid the recurrence of similar failures.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Boiler tube failure root cause analysis advisory system
    Gonzalez, H
    Chang, PS
    [J]. PROCEEDINGS OF THE TWENTY-NINTH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 1997, : 201 - 205
  • [32] ROOT-CAUSE ANALYSIS OF SUPERHEATER-TUBE FAILURE
    Nad, Martin
    Buzik, Jiri
    Letal, Tomas
    Losak, Pavel
    [J]. MATERIALI IN TEHNOLOGIJE, 2017, 51 (03): : 503 - 507
  • [33] NUMERICAL ANALYSIS OF CAVITATION SUSCEPTIBILITY FOR STEAM GENERATOR INTEGRAL PREHEATER TUBES
    Laroche, S.
    Sun, L.
    Pietralik, J.
    [J]. CNL NUCLEAR REVIEW, 2014, 3 (01) : 37 - 46
  • [34] Chemically cleaning a heat recovery steam generator
    不详
    [J]. MATERIALS PERFORMANCE, 2007, 46 (12) : 48 - 48
  • [35] Modeling of heat recovery steam generator performance
    Ongiro, A
    Ugursal, VI
    AlTaweel, AM
    Walker, JD
    [J]. APPLIED THERMAL ENGINEERING, 1997, 17 (05) : 427 - 446
  • [36] ROOT CAUSE FAILURE ANALYSIS OF A 373 MEGAWATT STEAM TURBINE GENERATOR EXHIBITING BOTH REVERSIBLE AND IRREVERSIBLE THERMAL SENSITIVITY
    Rakow, Alexi S.
    Edmonds, James S.
    Rakow, Joseph F.
    Brody, Richard D.
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 499 - +
  • [37] Modelling and practical studying of heat recovery steam generator (HRSG) drum dynamics and approach point effect on control valves
    Ahmed, Ahmed Shams El-din
    Elhosseini, Mostafa A.
    Ali, Hesham Arafat
    [J]. AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (04) : 3187 - 3196
  • [38] Failure Analysis of Low-Pressure Evaporator in Heat Recovery Steam Generator with 200 ton/h of Capacity
    Purwanto, Tri Sigit
    Permana, Diki Ismail
    Nurbanasari, Meilinda
    Abdurrachim
    Sirodz, Muhammad Pramuda Nugraha
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (06) : 2575 - 2587
  • [39] Failure Analysis of Low-Pressure Evaporator in Heat Recovery Steam Generator with 200 ton/h of Capacity
    Tri Sigit Purwanto
    Diki Ismail Permana
    Meilinda Nurbanasari
    Muhammad Pramuda Nugraha Abdurrachim
    [J]. Journal of Failure Analysis and Prevention, 2023, 23 : 2575 - 2587
  • [40] Fretting Fatigue Test and Simulation Analysis of Steam Generator Heat Transfer Tube
    Tang, Lichen
    Qian, Hao
    Li, Chen
    Wu, Xinqiang
    [J]. METALS, 2023, 13 (01)