Failure analysis of isolation valve stems in steam generator blow down system

被引:5
|
作者
Jung, Yong Chan [1 ]
Lee, Tae Hee [1 ]
Kim, Min Tae [1 ]
机构
[1] Korea Elect Power Res Inst, Taejon 305380, South Korea
关键词
Isolation valve; Stem failure; Full annealing; Mechanical properties;
D O I
10.1016/j.engfailanal.2013.03.006
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Two isolation valves failed prematurely in the steam generator blow down system of a nuclear power plant. Metallurgical analysis of the damaged stems in the isolation valves was made. Heat treatment tests were carried out to verify the reliability of stems in comparison with the required mechanical specifications. The results of the analysis showed the abnormal precipitation of nonmetallic inclusions, MnS, in the matrix. These nonmetallic inclusions which could acts as notches were distributed randomly to 0.2 vol.%, two times higher than those of typical materials. In addition, the hardness of the damaged stems was twofold higher and the elongation was reduced by half compared to those values attainable from a proper full annealing. It is concluded that improper tempering applied to the damaged stems resulted in second hardening and decrease in toughness, consequently shortening the life of the stems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 50 条
  • [21] LWRA analysis of inadvertent closing of the main steam isolation valve in NPP Krsko
    Feretic, D
    Cavlina, N
    Grgic, D
    Spalj, S
    3RD REGIONAL MEETING NUCLEAR ENERGY IN CENTRAL EUROPE / ANNUAL MEETING OF THE NUCLEAR SOCIETY OF SLOVENIA, PROCEEDINGS, 1996, : 309 - 316
  • [22] Root cause analysis of the failure of the steam generator orifice assembly of a test reactor
    Albert, Shaju K.
    Kumar, R. Suresh
    Kumar, Hemant
    Kumar, R. Nanda
    Toppo, Anita
    Poonguzhali, A.
    Elango, M.
    Babu, A.
    ENGINEERING FAILURE ANALYSIS, 2021, 129
  • [23] Parallel process system and its application to steam generator structural analysis
    Yoon-Suk Chang
    Han-Ok Ko
    Jae-Boong Choi
    Young-Jin Kim
    Shinobu Yoshimura
    Journal of Mechanical Science and Technology, 2005, 19 : 2007 - 2015
  • [24] Parallel process system and its application to steam generator structural analysis
    Chang, YS
    Ko, HO
    Choi, JB
    Kim, YJ
    Yoshimura, S
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (11) : 2007 - 2015
  • [25] Failure probabilistic analysis of steam generator heat-transfer tubing with pitting corrosion
    Zhou, B. H.
    Zhai, Z. Q.
    ENGINEERING FAILURE ANALYSIS, 2011, 18 (05) : 1333 - 1340
  • [26] Failure Analysis of Once-Through Steam Generator (OTSG) External Piping Welds
    Nitin Saini
    Yajing Wang
    Leijun Li
    Journal of Failure Analysis and Prevention, 2022, 22 : 1180 - 1195
  • [27] Corrosion Failure Analysis of Condensate Pre-Heater in Heat Recovery Steam Generator
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Kim, Kyung Min
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (02): : 69 - 76
  • [28] Failure Analysis of Once-Through Steam Generator (OTSG) External Piping Welds
    Saini, Nitin
    Wang, Yajing
    Li, Leijun
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (03) : 1180 - 1195
  • [29] Steam Turbine control valve and actuation system modeling for dynamics analysis
    Pondini, M.
    Signorini, A.
    Colla, V.
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 1651 - 1656
  • [30] Models of control valve and actuation system for dynamics analysis of steam turbines
    Pondini, Maddalena
    Colla, Valentina
    Signorini, Annamaria
    APPLIED ENERGY, 2017, 207 : 208 - 217