Comparison of Accuracy and Safety of the SEVEN and the Navigator Continuous Glucose Monitoring Systems

被引:54
|
作者
Garg, Satish K. [1 ,2 ,3 ]
Smith, James [1 ]
Beatson, Christie [1 ]
Lopez-Baca, Benita [1 ]
Voelmle, Mary [1 ]
Gottlieb, Peter A. [1 ,2 ,3 ]
机构
[1] Univ Colorado Denver, Sch Med, Barbara Davis Ctr Childhood Diabet, Aurora, CO 80045 USA
[2] Univ Colorado Denver, Sch Med, Dept Internal Med, Aurora, CO USA
[3] Univ Colorado Denver, Sch Med, Dept Pediat, Aurora, CO USA
关键词
BLOOD-GLUCOSE;
D O I
10.1089/dia.2008.0109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study evaluated the accuracy and safety of two continuous glucose monitoring (CGM) systems, the SEVEN (R) (DexCom (TM), San Diego, CA) and the Navigator (R) (Abbott Diabetes Care, Alameda, CA), with the YSI laboratory measurements of blood glucose (blood glucose meter manufactured by YSI, Yellow Springs, OH), when worn concurrently in adults with type 1 diabetes. Design and Methods: Fourteen subjects with type 1 diabetes, 33 +/- 6 (mean +/- SD) years old, were enrolled in this study. All subjects wore both sensors concurrently over three consecutive 5-day CGM sessions (15-day wear). On Days 5, 10, and 15, subjects participated in an 8-h in-clinic session where measurements from the CGM systems were collected and compared with YSI measurements every 15 min. At the end of Day 5 and 10 in-clinic sessions, the sensors were removed, and new sensors were inserted for the following CGM session despite the SEVEN system's recommended use for up to 7 days. Results: The mean absolute relative difference (ARD) for the two CGM devices versus YSI was not different: 16.8% and 16.1% for SEVEN and Navigator, respectively (P = 0.38). In the hypoglycemic region (YSI value <80 mg/dL), the mean ARD for SEVEN was lower than for Navigator (21.5% vs. 29.8%, respectively; P = 0.001). The data analyses were similar when compared with self-monitoring of blood glucose (SMBG) values. Thirteen additional Navigator replacement devices were issued compared to two for the SEVEN. A total of three versus 14 skin reactions were reported with the SEVEN and Navigator insertion area, respectively. Conclusions: Glucose measurements with the SEVEN and Navigator were found to be similar compared with YSI and SMBG measurements, with the exception of the hypoglycemic range where the SEVEN performed better. However, the Navigator caused more skin area reactions.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [41] Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice
    Ajjan, Ramzi A.
    Cummings, Michael H.
    Jennings, Peter
    Leelarathna, Lalantha
    Rayman, Gerry
    Wilmot, Emma G.
    DIABETES & VASCULAR DISEASE RESEARCH, 2018, 15 (03): : 175 - 184
  • [42] Evaluating the accuracy of continuous glucose-monitoring sensors
    Kovatchev, BP
    Gonder-Frederick, LA
    Cox, DJ
    Clarke, WL
    DIABETES CARE, 2004, 27 (08) : 1922 - 1928
  • [43] Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
    Narasaki, Yoko
    Kalantar-Zadeh, Kamyar
    Daza, Andrea C.
    You, Amy S.
    Novoa, Alejandra
    Peralta, Renal Amel
    Siu, Man Kit Michael
    Nguyen, Danh V.
    Rhee, Connie M.
    DIABETES CARE, 2024, 47 (11)
  • [44] Assessing Glucose Trend Accuracy with a Novel Continuous Glucose Monitoring System
    Johnson, Terri
    Zhang, Xiaohe
    Balo, Andrew
    DIABETES, 2018, 67
  • [45] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [46] Differentiation of post-prandial glucose profiles using the FreeStyle Navigator® continuous glucose monitoring system
    Dunn, Timothy C.
    Rebrin, Kerstin
    DIABETES, 2007, 56 : A105 - A105
  • [47] HOME BLOOD-GLUCOSE MONITORING - ACCURACY AND SAFETY
    WEST, TET
    TAYLOR, RP
    DIABETOLOGIA, 1986, 29 (08) : A606 - A606
  • [48] Comparison of subcutaneous and intravenous continuous glucose monitoring accuracy in an operating room and an intensive care unit
    Masaya Munekage
    Tomoaki Yatabe
    Masahiko Sakaguchi
    Hiroyuki Kitagawa
    Takahiko Tamura
    Tsutomu Namikawa
    Kazuhiro Hanazaki
    Journal of Artificial Organs, 2016, 19 : 159 - 166
  • [49] Comparison of subcutaneous and intravenous continuous glucose monitoring accuracy in an operating room and an intensive care unit
    Munekage, Masaya
    Yatabe, Tomoaki
    Sakaguchi, Masahiko
    Kitagawa, Hiroyuki
    Tamura, Takahiko
    Namikawa, Tsutomu
    Hanazaki, Kazuhiro
    JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (02) : 159 - 166
  • [50] Evaluating the Accuracy of Continuous Glucose Monitoring by the Patient through Continuous Glucose Error Grid Analysis
    Honsova, Sarka
    Navratil, Tomas
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 59 - 63