Comparison of Accuracy and Safety of the SEVEN and the Navigator Continuous Glucose Monitoring Systems

被引:54
|
作者
Garg, Satish K. [1 ,2 ,3 ]
Smith, James [1 ]
Beatson, Christie [1 ]
Lopez-Baca, Benita [1 ]
Voelmle, Mary [1 ]
Gottlieb, Peter A. [1 ,2 ,3 ]
机构
[1] Univ Colorado Denver, Sch Med, Barbara Davis Ctr Childhood Diabet, Aurora, CO 80045 USA
[2] Univ Colorado Denver, Sch Med, Dept Internal Med, Aurora, CO USA
[3] Univ Colorado Denver, Sch Med, Dept Pediat, Aurora, CO USA
关键词
BLOOD-GLUCOSE;
D O I
10.1089/dia.2008.0109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study evaluated the accuracy and safety of two continuous glucose monitoring (CGM) systems, the SEVEN (R) (DexCom (TM), San Diego, CA) and the Navigator (R) (Abbott Diabetes Care, Alameda, CA), with the YSI laboratory measurements of blood glucose (blood glucose meter manufactured by YSI, Yellow Springs, OH), when worn concurrently in adults with type 1 diabetes. Design and Methods: Fourteen subjects with type 1 diabetes, 33 +/- 6 (mean +/- SD) years old, were enrolled in this study. All subjects wore both sensors concurrently over three consecutive 5-day CGM sessions (15-day wear). On Days 5, 10, and 15, subjects participated in an 8-h in-clinic session where measurements from the CGM systems were collected and compared with YSI measurements every 15 min. At the end of Day 5 and 10 in-clinic sessions, the sensors were removed, and new sensors were inserted for the following CGM session despite the SEVEN system's recommended use for up to 7 days. Results: The mean absolute relative difference (ARD) for the two CGM devices versus YSI was not different: 16.8% and 16.1% for SEVEN and Navigator, respectively (P = 0.38). In the hypoglycemic region (YSI value <80 mg/dL), the mean ARD for SEVEN was lower than for Navigator (21.5% vs. 29.8%, respectively; P = 0.001). The data analyses were similar when compared with self-monitoring of blood glucose (SMBG) values. Thirteen additional Navigator replacement devices were issued compared to two for the SEVEN. A total of three versus 14 skin reactions were reported with the SEVEN and Navigator insertion area, respectively. Conclusions: Glucose measurements with the SEVEN and Navigator were found to be similar compared with YSI and SMBG measurements, with the exception of the hypoglycemic range where the SEVEN performed better. However, the Navigator caused more skin area reactions.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [31] Evaluating Clinical Accuracy of Continuous Glucose Monitoring Systems: Continuous Glucose - Error Grid Analysis (CG-EGA)
    Clarke, William L.
    Anderson, Stacey
    Kovatchev, Boris
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 193 - 199
  • [32] SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING: A COMPARISON
    Albuquerque, Andrea
    NURSING IN CRITICAL CARE, 2021, 26 : 29 - 29
  • [33] Accuracy and Reliability of currently available continuous Glucose Monitoring System (CGM) - a direct comparison
    Luijf, Y. M.
    De Vries, J. H.
    Mader, J. K.
    Doll, W.
    Pieber, T. R.
    Place, J.
    Renard, E.
    Bruttomesso, D.
    Filippi, A.
    Avogaro, A.
    Benesch, C.
    Heinemann, L.
    WIENER KLINISCHE WOCHENSCHRIFT, 2012, 124 : 10 - 10
  • [34] Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites
    Steineck, Isabelle Isa Kristin
    Mahmoudi, Zeinab
    Ranjan, Ajenthen
    Schmidt, Signe
    Jorgensen, John Bagterp
    Norgaard, Kirsten
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (05) : 295 - 302
  • [35] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
  • [36] Safety and Performance of Continuous Glucose Monitoring: An Overview
    Singh, Himadri
    Venkatesan, Vijayalakshmi
    CURRENT DIABETES REVIEWS, 2023, 19 (03) : 49 - 60
  • [37] Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review
    Nielsen, Christian G.
    Grigonyte-Daraskeviciene, Milda
    Olsen, Mikkel T.
    Moller, Morten H.
    Norgaard, Kirsten
    Perner, Anders
    Martensson, Johan
    Pedersen-Bjergaard, Ulrik
    Kristensen, Peter L.
    Bestle, Morten H.
    INTENSIVE CARE MEDICINE, 2024, 50 (12) : 2005 - 2018
  • [38] NEWER CONTINUOUS GLUCOSE MONITORING SYSTEMS
    Garg, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A2 - A2
  • [39] An Overview of Continuous Glucose Monitoring Systems
    Cox, Marilyn
    JOURNAL OF PEDIATRIC HEALTH CARE, 2009, 23 (05) : 344 - 347
  • [40] Continuous Glucose Monitoring Systems: A Review
    Vashist, Sandeep Kumar
    DIAGNOSTICS, 2013, 3 (04) : 385 - 412